Xrf x ray fluorescence - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Xrf x ray fluorescence? On this page you'll find 94 study documents about Xrf x ray fluorescence.

All 94 results

Sort by

  EPA Lead Inspector questions and answers latest top score. Popular
  • EPA Lead Inspector questions and answers latest top score.

  • Exam (elaborations) • 8 pages • 2023
  • Available in package deal
  • EPA Lead Inspector questions and answers latest top score. Lead-based paint (LBP) - correct answers.Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values - correct answers.- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troug...
    (0)
  • $10.99
  • 1x sold
  • + learn more
2023 WI Lead Risk Assessor Exam With Correct Questions & Answers(Verified)
  • 2023 WI Lead Risk Assessor Exam With Correct Questions & Answers(Verified)

  • Exam (elaborations) • 10 pages • 2023
  • Available in package deal
  • EPA and WI DHS Lead Based Paint Definition - ANSWERS≥0.5% ≥1.0 mg/cm2 Nationally houses built before 1978_______ have lead based pain - ANSWERS75% XRF - ANSWERSX-ray fluorescence Factors that should be considered for XRF: - ANSWERS- Substrate Correction - inconclusive range - measuring K & L shell reading What year was lead based paint banned? - ANSWERS1978 Only _______ areas that are in the scope of work from the contractor - ANSWERStesting areas Sampling requirements f...
    (0)
  • $10.99
  • 2x sold
  • + learn more
EPA Lead Inspector (Actual Test 100% verified; correctly solved)
  • EPA Lead Inspector (Actual Test 100% verified; correctly solved)

  • Exam (elaborations) • 9 pages • 2023
  • Available in package deal
  • Lead-based paint (LBP) correct answers Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values correct answers - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft > 2 sq ft (can be r...
    (1)
  • $10.59
  • 1x sold
  • + learn more
EPA Lead Inspector Questions and  Answers Graded A+
  • EPA Lead Inspector Questions and Answers Graded A+

  • Exam (elaborations) • 19 pages • 2024
  • EPA Lead Inspector Questions and Answers Graded A+ Lead-based paint (LBP) Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1...
    (0)
  • $9.99
  • + learn more
EPA Lead Inspector Latest Update  Graded A+
  • EPA Lead Inspector Latest Update Graded A+

  • Exam (elaborations) • 19 pages • 2024
  • Available in package deal
  • EPA Lead Inspector Latest Update Graded A+ Lead-based paint (LBP) Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft &...
    (0)
  • $9.99
  • + learn more
XRR XRF (X-ray reflectometry ,X-ray fluorescence) Questions and Answers 2023
  • XRR XRF (X-ray reflectometry ,X-ray fluorescence) Questions and Answers 2023

  • Exam (elaborations) • 4 pages • 2023
  • Available in package deal
  • XRR XRF (X-ray reflectometry ,X-ray fluorescence)
    (0)
  • $17.99
  • + learn more
EPA Lead Inspector exam 2024 with 100% correct answers
  • EPA Lead Inspector exam 2024 with 100% correct answers

  • Exam (elaborations) • 11 pages • 2024
  • Lead-based paint (LBP) correct answersAny varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values correct answers- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft > 2 sq ft (can be red...
    (0)
  • $15.49
  • + learn more
EPA Lead Inspector exam 2024 with 100% correct answers
  • EPA Lead Inspector exam 2024 with 100% correct answers

  • Exam (elaborations) • 11 pages • 2024
  • Lead-based paint (LBP) - correct answer Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values - correct answer - Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 400 μg/ft2 (100 μg/ft2 in NY) - Samples must be at 1 sq ft > 2 sq ft (ca...
    (0)
  • $15.49
  • + learn more
EPA Lead Inspector State Certification  Exam with Correct Answers 100%
  • EPA Lead Inspector State Certification Exam with Correct Answers 100%

  • Exam (elaborations) • 10 pages • 2024
  • EPA Lead Inspector State Certification Exam with Correct Answers 100% Lead-based paint (LBP) - CORRECT ANSWER-Any varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values - CORRECT ANSWER-- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells (troughs): 40...
    (0)
  • $12.99
  • + learn more
EPA LEAD INSPECTOR EXAM QUIZZES WITH ACCURATE ANSWERS
  • EPA LEAD INSPECTOR EXAM QUIZZES WITH ACCURATE ANSWERS

  • Exam (elaborations) • 12 pages • 2024
  • EPA LEAD INSPECTOR EXAM QUIZZES EPA LEAD INSPECTOR EXAM QUIZZES WITH ACCURATE ANSWERS Lead-based paint (LBP) - Accurate AnswerAny varnish, shallac, or coating that contains either- 1.0 mg/cm2 - 0.5 % by weight - 5000 ppm - Older instruments could not read accurately at 0.7, so the lead standard was updated to 1.0 Dust sample clearance values - Accurate Answer- Floors: 40 μg/ft2 > 10 μg/ft2 (10 μg/ft2 in NY) - Windows: 250 μg/ft2 > 100 μg/ft2 (50 μg/ft2 in NY) - Window wells...
    (0)
  • $12.49
  • + learn more