Ungrounded conductors - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Ungrounded conductors? On this page you'll find 352 study documents about Ungrounded conductors.

All 352 results

Sort by

ELECTRICAL TROUBLESHOOTING TPC  210 QUESTIONS AND ANSWERS  2024/2025 Popular
  • ELECTRICAL TROUBLESHOOTING TPC 210 QUESTIONS AND ANSWERS 2024/2025

  • Exam (elaborations) • 8 pages • 2024
  • On an electrical diagram, a control relay is indicated by the designation...  CR The NEC requires a fuse to be installed in all ______ conductors  ungrounded Cross-references to the different locations of limit switches in a diagram are provided by...  arrows next to the symbols line number A control panel layout shows the...  physical arrangement of all components A sequence of operation is used with...  an elementary diagram A riser diagram shows the...  power dist...
    (0)
  • $11.49
  • 1x sold
  • + learn more
Michigan Journeyman test Questions With Complete Solutions
  • Michigan Journeyman test Questions With Complete Solutions

  • Exam (elaborations) • 9 pages • 2023
  • Available in package deal
  • There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG correct answer: 4 Thermal insulation shall not be installed within _________inches of recessed lighting fixtures correct answer: 3 A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and on...
    (0)
  • $11.49
  • 2x sold
  • + learn more
Module 11 - Residential Electrical Services Questions and Answers 2023 with complete solution
  • Module 11 - Residential Electrical Services Questions and Answers 2023 with complete solution

  • Exam (elaborations) • 5 pages • 2023
  • Available in package deal
  • Module 11 - Residential Electrical Services Questions and Answers 2023 with complete solution A small residence has a floor area of 900 square feet. What is its general lighting load? 2,700VA Per NEC Table 220.54, a household with two dryers has a demand factor of __________. 100% If a dwelling has two kitchen areas, then the total small appliance branch circuits required would be __________. four at 1,500VA each A lighting load of 2,700VA at 120V has an amperage of __________. 22.5A ...
    (1)
  • $13.49
  • 1x sold
  • + learn more
Michigan Journeyman test | 2023/24 questions and answers
  • Michigan Journeyman test | 2023/24 questions and answers

  • Exam (elaborations) • 4 pages • 2023
  • Available in package deal
  • Michigan Journeyman test | 2023/24 questions and answers There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 3 A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and on...
    (0)
  • $9.49
  • 1x sold
  • + learn more
GROUNDING II EXAM QUESTIONS AND ANSWERS
  • GROUNDING II EXAM QUESTIONS AND ANSWERS

  • Exam (elaborations) • 31 pages • 2024
  • A ? is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). - Answer-branch circuit A ? includes all circuit conductors between the service equipment, the source of a separately derived system, or other power supply source, and the final branch-circuit overcurrent device. - Answer-feeder A grounding electrode system is generally required for each building or structure served by a feeder. - Answer-True According to the NEC, that...
    (0)
  • $13.99
  • + learn more
Residential Wireman Electrical Exam - Larry Bobo(GRADED A)
  • Residential Wireman Electrical Exam - Larry Bobo(GRADED A)

  • Exam (elaborations) • 15 pages • 2024
  • The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt single phase underground dwelling feeder whose ungrounded conductors have been increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper Ampacities, Grounding 250.122(B) Table 250.122 Table 8 Ch 9 - ANSWER 4 The continuity of the grounded conductor shall depend on a busbar or __ only. Continuity, Grounded conductors 200.12 - ANSWER wire. Each multi-wire branch circuit shall be provided with...
    (0)
  • $12.99
  • + learn more
Master Electrician's Exam Prep Guide Final Exam #1 CORRECT 100%
  • Master Electrician's Exam Prep Guide Final Exam #1 CORRECT 100%

  • Exam (elaborations) • 33 pages • 2024
  • Given: after all demand factors have been taken into consideration for an office building, the demand load is determined to be 90,000 VA; the building has a 120/240-volt, single phase electrical system. What MIN. size copper conductors with THHN/THWN insulation are required for the ungrounded service-lateral conductors? Consider all termination lugs are rated for 75 deg. C. A. 400 kcmil B. 350 kcmil C. 300 kcmil D. 500 kcmil - ANSWER D. 500 kcmil pg. 142, 153, 161 Given: a commercial b...
    (0)
  • $13.99
  • + learn more
MASTER ELECTRICIAN TEST 211 With Verified Solutions Graded A+
  • MASTER ELECTRICIAN TEST 211 With Verified Solutions Graded A+

  • Exam (elaborations) • 25 pages • 2024
  • Given: Two separate Services are identical in voltage and amperage, except that one service serves only motor - loads and the other serves lighting loads only. in the event of a short circuit in these services, the available short circuit current will be: A) The same in either service B) Higher in the motor-load service C) Higher in the lighting -load service D) 25% greater in the service for the motor load - The same in either service (general knowledge) A device that requires a portabl...
    (0)
  • $9.49
  • + learn more
IEC 2A Questions and Answers with  Verified Solutions
  • IEC 2A Questions and Answers with Verified Solutions

  • Exam (elaborations) • 128 pages • 2024
  • Available in package deal
  • IEC 2A Questions and Answers with Verified Solutions ___ AWG ungrounded conductors are installed from BCES Transformer XE to Panel LE. Select one: a. 4 b. 3/0 c. 4/0 d. 8 e. 2 2 ___ is a type of lamp used in an HID luminaire.I. Mercury-vapor II. Metal halide III. Nickel cadmium Select one: a. I & III only b. I only c. II only d. I & II only e. I, II, & III f. II & III only I & II only ___ is defined as case or housing of apparatus, or the fence or walls surroundin...
    (0)
  • $12.49
  • + learn more
MASTER ELECTRICIAN PRACTICE EXAMS  2024/2025 WITH COMPLETE SOLUTIONS
  • MASTER ELECTRICIAN PRACTICE EXAMS 2024/2025 WITH COMPLETE SOLUTIONS

  • Exam (elaborations) • 392 pages • 2024
  • The following questions are based on the 2020 edition of the National Electrical Code® and are typical of questions that may be encountered on most Master Electricians’ licensing exams. Select the best answer from the choices given and review your answers with the answer key. 1. What MINIMUM size ungrounded (phase) THWN copper service-entrance conductors are required for a 208Y/120-volt, 72,000 VA 3-phase commercial service? a. 250 kcmil b. 2/0 AWG c. 3/0 AWG d. 4/0 AWG 2. E...
    (0)
  • $23.49
  • + learn more