Oil burner motor - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Oil burner motor? On this page you'll find 245 study documents about Oil burner motor.

All 245 results

Sort by

Boilermaker NCCR Test   Questions And Answers Popular
  • Boilermaker NCCR Test Questions And Answers

  • Exam (elaborations) • 10 pages • 2024
  • Boilermaker NCCR Test Questions And Answers Boilermaker NCCR Test 1 ft 3-3/4 in + 2 ft 1-1/16 in +5 ft 10- 7/8 in = - ANS 9 ft 3-11/16 in A 1-inch plate is to be cut. Why should an acetylene gerulator on a cutting rig not be adjusted over 15 PSI? - ANS Acetylene is unstable above this pressure A big control valve is pulled who is responsible for the rigging? - ANS Crane operator and rigger A boiler maker must have all of the following wh...
    (0)
  • $10.99
  • 2x sold
  • + learn more
Oil Burner License Exam 2023 Questions and Answers
  • Oil Burner License Exam 2023 Questions and Answers

  • Exam (elaborations) • 18 pages • 2023
  • Available in package deal
  • What is the first thing a tech should do when arriving at a no combustion call? - Answer- Ask how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - Answer- False When in the presence of a flame, a cad cell normally reads.. - Answe...
    (2)
  • $12.49
  • 4x sold
  • + learn more
Journeyman Oil Exam Questions and Answers 100% Correct
  • Journeyman Oil Exam Questions and Answers 100% Correct

  • Exam (elaborations) • 34 pages • 2024
  • Available in package deal
  • Journeyman Oil Exam Questions and Answers 100% CorrectJourneyman Oil Exam Questions and Answers 100% CorrectJourneyman Oil Exam Questions and Answers 100% CorrectJourneyman Oil Exam Questions and Answers 100% Correct TT terminals are normally used for? A. Line 1 B. Neutral C. Thermostat D. Burner load - ANSWER-C. Thermostat The stack mount primary control must be ______ prior to use. A. Stepped on B. Put in step C. Reset D. None of the above - ANSWER-B. Put in step The ECM (e...
    (0)
  • $15.99
  • + learn more
NORA REVIEW QUESTIONS WITH 100% VERIFIED CORRECT ANSWERS
  • NORA REVIEW QUESTIONS WITH 100% VERIFIED CORRECT ANSWERS

  • Exam (elaborations) • 14 pages • 2024
  • Available in package deal
  • NORA REVIEW QUESTIONS WITH 100% VERIFIED CORRECT ANSWERS In a typical oil burner, the motor drives: - Correct Answer Both the fuel unit and the fan The key final adjustment for most oil burners is: - Correct Answer Combustion air High static air pressure burners: - Correct Answer Enable boilers and furnaces to have tighter more efficient heat exchanger passages Dirt or lint build-up on the burnerfan blades will: - Correct Answer Reduce the amount of combustion air One gallon of #2 o...
    (0)
  • $9.99
  • + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)

  • Exam (elaborations) • 20 pages • 2024
  • Available in package deal
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - Answer- False When in the presence of a flame, a cad cell normally reads.. - Answer- 300-1000 ohms If a pump is used to bring oil to a l...
    (0)
  • $14.49
  • + learn more
HVACR UNIT 55 QUESTIONS AND ANSWERS ALREADY PASSED
  • HVACR UNIT 55 QUESTIONS AND ANSWERS ALREADY PASSED

  • Exam (elaborations) • 24 pages • 2024
  • Available in package deal
  • HVACR UNIT 55 QUESTIONS AND ANSWERS ALREADY PASSED A major difference between the operation of an oil furnace and a gas furnace is that: The oil must be atomized before ignition. An oil furnace heat exchanger is built: Like a drum. How are oil burner nozzles rated? Cone shape, spray angle, and GPH Modern residential oil furnaces sense the flames using: A cadmium sulfide cell. Sealed combustion oil furnaces use: High static oil burners. Select the functions that the primary co...
    (0)
  • $9.99
  • + learn more
Oil burner's test questions 1-200  Questions With 100% Correct Answers.
  • Oil burner's test questions 1-200 Questions With 100% Correct Answers.

  • Exam (elaborations) • 19 pages • 2024
  • Available in package deal
  • In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - Answer-Increase Atomizing type burners were designed to burn which type of fuel - Answer-Type 2 fuel oil Pour point problems with outside above ground fuel tanks can be partially relieved by - Answer-Reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. A fuel oil storage tank cannot be installed - Answer-In the furnace room with 5' of heating unit. The primary purpo...
    (0)
  • $9.69
  • + learn more
Oil burner's test questions 1-200
  • Oil burner's test questions 1-200

  • Exam (elaborations) • 14 pages • 2024
  • In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - Answer-Increase Atomizing type burners were designed to burn which type of fuel - Answer-Type 2 fuel oil Pour point problems with outside above ground fuel tanks can be partially relieved by - Answer-Reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. A fuel oil storage tank cannot be installed - Answer-In the furnace room with 5' of heating unit. The primary...
    (0)
  • $12.49
  • + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)

  • Exam (elaborations) • 20 pages • 2024
  • Available in package deal
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - A...
    (0)
  • $13.99
  • + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)

  • Exam (elaborations) • 20 pages • 2024
  • Available in package deal
  • Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - A...
    (0)
  • $14.99
  • + learn more
Oil Burners Questions and Answers  Rated A+
  • Oil Burners Questions and Answers Rated A+

  • Exam (elaborations) • 15 pages • 2024
  • Available in package deal
  • Oil Burners Questions and Answers Rated A+ According to NFPA31-2001, what is the minimum size of the vent pipe on an oil storage tank 1 1/4 inch Nozzles are available with three different spray patterns: Solid, semi-hollow, hollow What type of motor is used on a residential high pressure oil burner Split phase The most common motor speeds used in amerian made burners are 1725 and 3250 rpm If an oil has a high viscosity It is a thicker oil A service technician performs a com...
    (0)
  • $9.99
  • + learn more