Nate air conditioning - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Nate air conditioning? On this page you'll find 293 study documents about Nate air conditioning.

All 293 results

Sort by

NATE Air Conditioning and Heat Pump Exam 2023
  • NATE Air Conditioning and Heat Pump Exam 2023

  • Exam (elaborations) • 15 pages • 2023
  • Available in package deal
  • NATE Air Conditioning and Heat Pump Exam 2023
    (0)
  • $11.49
  • 1x sold
  • + learn more
NATE Air Conditioning and Heat Pump EXAM 2024/25
  • NATE Air Conditioning and Heat Pump EXAM 2024/25

  • Exam (elaborations) • 29 pages • 2024
  • Available in package deal
  • NATE Air Conditioning and Heat Pump NATE Air Conditioning and Heat Pump
    (0)
  • $9.99
  • + learn more
NATE Air Conditioning Exam 1 Questions with Verified Answers | Latest 2024/2025
  • NATE Air Conditioning Exam 1 Questions with Verified Answers | Latest 2024/2025

  • Exam (elaborations) • 16 pages • 2024
  • Available in package deal
  • NATE Air Conditioning Exam 1 Questions with Verified Answers | Latest 2024/2025
    (0)
  • $12.49
  • + learn more
NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024/2025 (GRADED)
  • NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024/2025 (GRADED)

  • Exam (elaborations) • 15 pages • 2024
  • Available in package deal
  • NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024/2025 (GRADED) The combined output of a heatpump and its auxiliary heat should not exceed the calculated heat loss of a home by more than ____%. - ANSWER-15% What amount of auxiliary electronic heat is needed when the output of a heat pump on a design day equals 18,800 Btuh and the heat loss of a home is 29,700 Btuh? - ANSWER-3.2 kWh The three processes that transfer heat energy are conduction, convection, and _____...
    (0)
  • $15.99
  • + learn more
NATE Exam Air Conditioning and Heat Pumps Questions Verified With 100% Correct Answers Latest 2023 - 2024
  • NATE Exam Air Conditioning and Heat Pumps Questions Verified With 100% Correct Answers Latest 2023 - 2024

  • Exam (elaborations) • 41 pages • 2023
  • NATE Exam Air Conditioning and Heat Pumps Questions Verified With 100% Correct Answers Latest 2023 - 2024
    (0)
  • $9.99
  • 2x sold
  • + learn more
NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024-2025 (GRADED A+)
  • NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024-2025 (GRADED A+)

  • Exam (elaborations) • 15 pages • 2024
  • Available in package deal
  • NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated (GRADED A+) The maximum sensible cooling capacity of a heat pump should be within ______% of the calculated sensible heat gain of a structure with a large heating load. - ANSWER- +25% The combined output of a heatpump and its auxiliary heat should not exceed the calculated heat loss of a home by more than ____%. - ANSWER-15% What amount of auxiliary electronic heat is needed when the output of a heat pump on a design d...
    (0)
  • $18.49
  • + learn more
NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024-2025 (GRADED A+)
  • NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated 2024-2025 (GRADED A+)

  • Exam (elaborations) • 15 pages • 2024
  • Available in package deal
  • NATE Air Conditioning and Heat Pump Exam Questions and Answers Updated (GRADED A+) The maximum sensible cooling capacity of a heat pump should be within ______% of the calculated sensible heat gain of a structure with a large heating load. - ANSWER- +25% The combined output of a heatpump and its auxiliary heat should not exceed the calculated heat loss of a home by more than ____%. - ANSWER-15% What amount of auxiliary electronic heat is needed when the output of a heat pump on a design d...
    (0)
  • $17.49
  • + learn more
NATE Exam Air Conditioning and Heat Pumps Exam Questions with 100% Correct Answers | Updated | Download to score A+
  • NATE Exam Air Conditioning and Heat Pumps Exam Questions with 100% Correct Answers | Updated | Download to score A+

  • Exam (elaborations) • 59 pages • 2024
  • Available in package deal
  • 1. Which of the following factors affects a customer's level of comfort? a. Air movement b. Humidity c. Temperature d. All of the above ANS d (All of the above air movement, humidity, temperature) 2. A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within % of this calculated value. a. ±10% b. +10% c. +15% d. +30% ANS c (+15%) 3. The maximum sensible cooling capacity of a heat pump shou...
    (0)
  • $12.99
  • + learn more
NATE Air Conditioning and Heat Pumps Exam Latest Updated Graded A+
  • NATE Air Conditioning and Heat Pumps Exam Latest Updated Graded A+

  • Exam (elaborations) • 19 pages • 2023
  • Available in package deal
  • NATE Air Conditioning and Heat Pumps Exam Latest Updated Graded A+
    (0)
  • $12.99
  • + learn more
NATE Exam: Air Conditioning and Heat Pumps || with Accurate Answers 100%.
  • NATE Exam: Air Conditioning and Heat Pumps || with Accurate Answers 100%.

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • Which of the following factors affects a customer's level of comfort? a. Air movement b. Humidity c. Temperature d. All of the above correct answers d (All of the above: air movement, humidity, temperature) A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible capacity of a cooling-only system should be within ____% of this calculated value. a. ±10% b. +10% c. +15% d. +30% correct answers c (+15%) The maximum sensible cooling capacit...
    (0)
  • $12.39
  • + learn more