There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG correct answer: 4 
 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures correct answer: 3 
 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and on...
-
Michigan Journeyman test | 2023/24 questions and answers
- Exam (elaborations) • 4 pages • 2023
- Available in package deal
-
- $9.49
- 1x sold
- + learn more
Michigan Journeyman test | 2023/24 questions and answers 
 
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - 4 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 3 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and on...
-
Michigan Journeyman Test | 2023 | 75 Questions with 100% Correct Answers | Updated & Verified
- Exam (elaborations) • 10 pages • 2023
- Available in package deal
-
- $12.49
- 1x sold
- + learn more
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 
70 amp load using THHM conductors. The minimum size conductors used our 
#_________AWG - 4 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 
3 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 
TW. Each circuit consist of two phase conductors and one grounding conductor and one 
equipment grounding conduct...
-
Michigan Journeyman test exam 2023 with 100% correct answers
- Exam (elaborations) • 7 pages • 2023
- Available in package deal
-
- $13.49
- 1x sold
- + learn more
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG correct answers4 
 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures correct answers3 
 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 TW. Each circuit consist of two phase conductors and one grounding conductor and one eq...
Get paid weekly? You can!
-
Michigan Journeyman Test
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Michigan Journeyman Test 
 
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 
70 amp load using THHM conductors. The minimum size conductors used our 
#_________AWG - 4 
 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - 
3 
 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are number 10 
TW. Each circuit consist of two phase conductors and one grounding conductor and ...
-
Michigan Journeyman Test 2024-100% solved
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
Michigan Journeyman Test 2024-100% solved 
There are six conductors in a race way connected to 75° C rated circuit breaker. Each 
wire has a 70 amp load using THHM conductors. The minimum size conductors used 
our #_________AWG -Answer-4 
Thermal insulation shall not be installed within _________inches of recessed lighting 
fixtures -Answer-3 
A 1 inch conduit contains three wire circuits or a phase system. All conductors are 
number 10 TW. Each circuit consist of two phase conductors and one g...
-
Michigan Journeyman test Questions With Correct Answers Graded A+
- Exam (elaborations) • 5 pages • 2024
-
- $10.99
- + learn more
Michigan Journeyman test Questions With Correct Answers Graded A+
-
Michigan Journeyman test Latest Update 2024-2025 Actual Exam Questions and 100% Verified Correct Answers Guaranteed A+
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $20.49
- + learn more
Michigan Journeyman test Latest Update Actual Exam Questions and 100% Verified Correct Answers Guaranteed A+
-
Michigan Journeyman test With Solutions 100% Solved
- Exam (elaborations) • 12 pages • 2024
-
- $15.49
- + learn more
Michigan Journeyman test With Solutions 
100% Solved 
A general purpose receptacle shall not be installed on the_________ Offense directly 
south of the pool 
A junction box for a 124 wet niche fixture shall be at least_______Inches above the ground 
 4 
A GFCI protected_______ receptacle for the pump motor May be installed on the south side of 
the dwelling unit dedicated grounding type Dedicated receptacle 
A metal fence installed within________Feet of a pool Shall be bonded 5 
The feed to...