Helical ct scan - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Helical ct scan? On this page you'll find 145 study documents about Helical ct scan.
All 145 results
Sort by
-
CT Registry Review (MIC) Questions and Answers Rated 100%
- Exam (elaborations) • 71 pages • 2023
-
- $11.99
- 2x sold
- + learn more
CT Registry Review (MIC) Questions and Answers Rated 100% 
 
In order for an x-ray photon to be measured it must: 
1. enter the detector chamber 
2. be absorbed by the detector material 
3. be converted to a measurable event *ANS* 1,2,3 
 
Which system component converts the projection attenuation data into the proper digital form for the array processor? *ANS* analog-to-digital converter 
 
Which of the following is NOT a function of a PACS system? 
a. reconstruction of the image from the raw d...
-
SAEM Practice Exam Questions & Answers with Complete Solutions Graded A 2023
- Exam (elaborations) • 200 pages • 2023
-
- $15.00
- 1x sold
- + learn more
Regarding the diagnosis of acute appendicitis, all the following are true EXCEPT: 
A. Vital signs are usually abnormal, even early in the course of acute appendicitis. 
B. Rebound is usually elicited only after the appendix has ruptured or infarcted. 
C. Rovsing's sign is pain in the right lower quadrant upon palpation of the left 
lower quadrant. 
D. The obturator sign is pain upon flexion and internal rotation of the hip. 
E. The psoas sign is pain upon extension of the hip. - A. Vital signs ...
-
CT registry- image production Exam Questions and Answers 100% Pass
- Exam (elaborations) • 48 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
CT registry- image production Exam 
Questions and Answers 100% Pass 
Fundamental principle of ct may be summarized as - Correct Answer ️️ -An image of 
an object may be reconstructed on the basis of the attenuation that occurs as x 
radiation is transmitted through it 
Detectors measure - Correct Answer ️️ -The radiation that is transmitted through the 
pt. An image is reconstructed in the basis of the magnitude of X-ray attenuation that 
occurs at spatially distributed points within the...
-
Computed Tomography ARRT (Image Production) QUESTIONS & ANSWERS 100% ACCURATE!!
- Exam (elaborations) • 27 pages • 2024
- Available in package deal
-
- $14.99
- + learn more
data acquisition correct answers the measurement of the attenuation that occurs along each path through the patient from the x-ray tube to the detector 
 
data reconstruction correct answers computerized processing of the transmission measurements into the CT image 
 
multidimensional image display correct answers display of the reconstructed grayscale image in two-dimensional and / or 3-D format ; representation of the attenuation that occurred across the scanned volume of tissue 
 
image archi...
-
SAEM Practice 2020/ 508 Questions with Verified Answers & Rationales/ 2024-2025.
- Exam (elaborations) • 253 pages • 2024
- Available in package deal
-
- $23.49
- + learn more
SAEM Practice 2020/ 508 Questions with Verified Answers & Rationales/ . Terms like: 
 
A 46 year old woman presents to the emergency department complaining of abrupt onset of intermittent severe pain in the left flank and abdomen that woke her from sleep. She is pacing around the stretcher and appears extremely uncomfortable. She has never experienced this type of pain previously and denies fevers or other symptoms. Renal calculus is suspected. Which of the following is true regarding the diagn...
Too much month left at the end of the money?
-
CT registry- image production Exam Questions and Answers 100% Pass
- Exam (elaborations) • 48 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
CT registry- image production Exam 
Questions and Answers 100% Pass 
Fundamental principle of ct may be summarized as - Correct Answer ️️ -An image of 
an object may be reconstructed on the basis of the attenuation that occurs as x 
radiation is transmitted through it 
Detectors measure - Correct Answer ️️ -The radiation that is transmitted through the 
pt. An image is reconstructed in the basis of the magnitude of X-ray attenuation that 
occurs at spatially distributed points within the...
-
ASRT 50 modules review Questions With Answers
- Exam (elaborations) • 17 pages • 2024
-
- $7.99
- + learn more
Which of the following postprocessing techniques uses 100% of the data set? A) Multiplanar reconstruction B) Shaded surface rendering C) Maximum intensity projections D) Volume rendering - ️️VR 
Which of the following statements regarding retrospective ECG gating is true? 
A) It results in lower patient dose than prospective ECG gating. 
B) It uses a continuous helical acquisition throughout the ECG-monitored scan range. 
C) It is more prone to motion artifacts and image misregistration. ...
-
CT Flashcards || QUESTIONS & ANSWERS 100% VERIFIED!!
- Exam (elaborations) • 9 pages • 2024
-
- $11.39
- + learn more
Which CT system is capable of helical scanning? correct answers volume CT scanners 
1. 3rd generation (960) detectors 
2. 4th generation 
3. EBCT - electronic beam CT 
 
Which generation of CT scanner utilized a (360) degree rotation of the x-ray tube around the patient? correct answers 3rd generation scanner 
 
Which generation of CT scanner utilizes a fixed ring of detectors? correct answers 4th generation (4800) detectors 
 
What are the advantages of CT over conventional imaging? correct ans...
-
ASRT 140 PROCEDURE WITH QUESTIONS AND ANSWERS
- Exam (elaborations) • 18 pages • 2024
-
- $7.99
- + learn more
Which scanners produce a higher mA setting, with shorter tube rotation times (of 0.5 seconds)? - ️️64 slice helical scanners 
Who might require More Contrast and Faster Injection Rates (up to 6 to 8 mL/sec)? - ️️Larger patients; in order to achieve a diagnostic study 
Why are both AP and Lateral Scouts useful in scanning the spine? - ️️Help establish smallest possible DFOV 
Why are pts instructed to extend arms overhead in CT scans of Chest/Abd? - ️️Prevent beam hardening artifa...
-
CT image production post course assessment || QUESTIONS & ANSWERS 100% PASSED!!
- Exam (elaborations) • 13 pages • 2024
-
- $12.49
- + learn more
The phantom pictured below contains only water. Based on the ROI readings what problem should be reported to the medical physicist? correct answers Unacceptable uniformity 
 
What artifact is visible in the image below in the posterior portion of the patient's abdomen? correct answers Beam hardening artifact 
 
What two computed tomography (CT) artifacts are demonstrated in the following image? (Select two) correct answers Beam hardening artifact 
Ring artifact 
 
A technologist review a patien...
$6.50 for your textbook summary multiplied by 100 fellow students... Do the math: that's a lot of money! Don't be a thief of your own wallet and start uploading yours now. Discover all about earning on Stuvia