NFPA 10 Exam 99 Questions with Verified Answers,100% CORRECT
- Exam (elaborations) • 10 pages • 2023
- Available in package deal
-
- $11.49
- 9x sold
- + learn more
NFPA 10 Exam 99 Questions with Verified Answers 
 
(SI) - CORRECT ANSWER International System of Units 
 
1 in=. mm - CORRECT ANSWER 25.4 
 
Approved - CORRECT ANSWER Acceptable to the authority having jurisdiction. 
 
(AHJ) - CORRECT ANSWER Authority Having Jurisdiction 
O rganization, office or individual responsible for enforcing requirements of a code or standard, or for approving equipment, materials, an installation or procedure. 
 
Shall - CORRECT ANSWER Indicates a mandatory requirement....
-
NFPA 10 Exam 71 Questions with Verified Answers,100% CORRECT
- Exam (elaborations) • 9 pages • 2023 Popular
- Available in package deal
-
- $11.39
- 4x sold
- + learn more
NFPA 10 Exam 71 Questions with Verified Answers 
 
When should wheeled fire extinguishers be considered? - CORRECT ANSWER • High hazard areas are present. 
• Limited available personnel are present. 
Requiring: High agent flow rate, Increased agent stream range, increased agent capacity 
 
NON-DOT low pressure fire extinguisher cylinders that pass a hydrostatic test shall have the following recorded on a label: - CORRECT ANSWER • Month and year test was performed (perforated) 
• Test pre...
-
S12 Sprinkler Chart Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A
- Exam (elaborations) • 26 pages • 2023
- Available in package deal
-
- $10.99
- 2x sold
- + learn more
S12 Sprinkler Chart Exam (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A 
 
Q: During an operational test of a foam water sprinkler system, if the nozzles are plugged what color tag is used? 
 
 
Answer: 
Red 
 
 
 
Q: Steel water storage tanks without corrosive protection are to be inspected how often? 
 
 
Answer: 
3 years 
 
 
 
Q: A sprinkler head with a white frame has a temperature rating of? 
 
 
Answer: 
175 - 225°F 
 
 
 
Q: The weekly test of an electr...
-
F80 Exam Questions and Answers Graded A
- Exam (elaborations) • 14 pages • 2023
- Available in package deal
-
- $9.99
- 6x sold
- + learn more
F80 Exam Questions and Answers Graded A After what date was the F-24 certificate of Fitness not recognized. July 31, 2014 
How often must this certificate be renewed? Every 3 years 
In what types of buildings and occupancies are coordinators of fire safety and alarm systems in homeless shelter required? Homeless shelters, one-way voice communication systems, or occupied for more tha n fifteen persons for a period of more than 30 days. 
What is the certificate of occupancy? Determines the number ...
-
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023.
- Exam (elaborations) • 20 pages • 2023
-
- $13.09
- 8x sold
- + learn more
Certificate of Fitness for Citywide Sprinkler Systems (S-12) 
S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Spring 2023. 
 
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. 
 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. 
 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY WITH REQUIREMENTS. 
 
REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN ________ FLOOR(S) ARE CONSIDERED PLANN...
Too much month left at the end of the money?
-
S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS || All Answers Are Correct 100%.
- Exam (elaborations) • 29 pages • 2024
- Available in package deal
-
- $15.79
- 1x sold
- + learn more
fire department connection correct answers normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. 
 
system control valve correct answers valve controlling flow to water-based fire protection systems. 
 
fire command center correct answers Designated room or area in a structure where the status of the fire detection, alarm, and protection systems is ...
-
ATI RN Comprehensive Predictor 2024 A NGN Questions Included REAL EXAM
- Exam (elaborations) • 44 pages • 2024
- Available in package deal
-
- $30.49
- 4x sold
- + learn more
ATI RN Comprehensive Predictor 2024 A 
 
 
A nurse is preparing to initiate intravenous fluids via an infusion pump for a client. Which of the following actions should the nurse take? 
Check the expiration date of the safety inspection sticker of the pump. 
 
 
A nurse is caring for a client who has an implanted venous access port. Which of the following should the nurse use to access the port? 
A non-coring needle 
 
 
A nurse is caring for a client who is near the end of life and is on comple...
-
S12 Sprinkler Test, S13 Standpipe Test, Sprinklers Segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS Already Passed
- Exam (elaborations) • 67 pages • 2024
- Available in package deal
-
- $11.99
- 1x sold
- + learn more
S12 Sprinkler Test, S13 Standpipe Test, Sprinklers Segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS Already Passed fire department connection normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. 
system control valve valve controlling flow to water-based fire protection systems. 
fire command center Designated room or area in a structure where the status...
-
S-13 COF FDNY STUDY MATERIAL| 75 QUESTIONS WITH 100% CORRECT ANSWERS|GUARANTEED SUCCESS
- Exam (elaborations) • 10 pages • 2023
- Available in package deal
-
- $15.49
- 3x sold
- + learn more
all records 
must be kept on site for 3 years 
 
 
 
planned removal from service 
When the system or portion of standpipe system is placed out of service for inspection, testing, maintenance, etc. , no more than one floor can be out of service and notification must be made to impairment coordinator 
 
 
 
Unplanned out of service condition: 
A serious defect in the standpipe or sprinkler system including, but not limited to: an empty tank, a break or major leak in the system's water piping, in...
-
TFM02: Extinguisher Inspection Test with correct answers
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $11.99
- 2x sold
- + learn more
Clean Agent ANS: - Electrically non-conducting, volatile, or gaseous fire extinguishant that does not leave a residue upon evaporation. 
 
High-Pressure Cylinder ANS: - containing nitrogen, compressed air, carbon dioxide, or other gases at a pressure higher than 500 psi (3447 kPa) at 70°F (21°C). 
 
Low-Pressure Cylinder ANS: - containing fire- extinguishing agent (medium), nitrogen, compressed air, or other compressed gases at a service pressure of 500 psi (3447 kPa) or lower at 70°...
-
Fire Apparatus D/O – Pumper (Total Force VLC) Questions and Answers 100% Solved
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $15.49
- 1x sold
- + learn more
Fire Apparatus D/O – Pumper (Total 
Force VLC) Questions and Answers 
100% Solved 
On a vacuum service test, the system, vacuum and pump priming device should achieve a 
column of mercury of at least ️️22 inches 
Fire pump service test are conducted at a minimum ️️Once a year 
All of the following are rescue tools, except ️️Drills 
It's recommended that fuel oil and mileage records to be updated ️️ 
You should have a spotter under all of the following conditions, except ️...