Amplitude prp and prf - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Amplitude prp and prf? On this page you'll find 57 study documents about Amplitude prp and prf.

All 57 results

Sort by

ARDMS SPI STUDY GUIDE QUESTIONS AND ANSWERS ALREADY PASSED
  • ARDMS SPI STUDY GUIDE QUESTIONS AND ANSWERS ALREADY PASSED

  • Exam (elaborations) • 35 pages • 2023
  • Available in package deal
  • ARDMS SPI STUDY GUIDE QUESTIONS AND ANSWERS ALREADY PASSED In soft tissue, if the frequency of a wave is increased the Propagation Speed (PS) will... Remain the Same because stiffness and density affect Propagation Speed. What is the audible range? 20-20,000Hz >20,000Hz=Ultrasound Frequency is measured in Hertz (Hz) is Cycles per Second Not affected by sonographer Increase Frequency; Decrease Depth A period is the length of time it takes for one complete wavelength to pass a fixed poin...
    (1)
  • $9.99
  • 2x sold
  • + learn more
Exam Review Sonographic Principles and instrumentation Penny Questions and answers
  • Exam Review Sonographic Principles and instrumentation Penny Questions and answers

  • Exam (elaborations) • 48 pages • 2024
  • Which is described as the ability of an object to resist compression and relates to the harness of a medium a stiffness b density c pressure d inertia a Stiffness An increase in PRF would lead to a an increase in DF b a decrease in PD c an increase in the number of cycles d decrease in resolution a an increase in DF Which of the following would have the highest propagation speed a air b bone c soft tissue d water b bone As imaging depth increases, PRF must: a...
    (0)
  • $13.49
  • + learn more
Sonography Canada Core Review Exam 2023.
  • Sonography Canada Core Review Exam 2023.

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • Sonography Canada Core Review Exam 2023. f - ANSWER v/wavelength frequency - ANSWER number of cycles per second T - ANSWER 1/f Period - ANSWER length of time for one cycle 1540 m/s - ANSWER speed of sound in soft tissue infrasound - ANSWER <20Hz audible sound - ANSWER 20Hz-20,000Hz ultrasound - ANSWER >20,000Hz c - ANSWER = root (bulk modulus/density) or =stiffness/density bulk modulus - ANSWER stress/strain I - ANSWER = P/a P - ANSWER = E/T Amplitude - ANSWER maximum deviat...
    (0)
  • $11.99
  • + learn more
Sonography Canada Core Review Exam 2023.
  • Sonography Canada Core Review Exam 2023.

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • Sonography Canada Core Review Exam 2023. f - ANSWER v/wavelength frequency - ANSWER number of cycles per second T - ANSWER 1/f Period - ANSWER length of time for one cycle 1540 m/s - ANSWER speed of sound in soft tissue infrasound - ANSWER <20Hz audible sound - ANSWER 20Hz-20,000Hz ultrasound - ANSWER >20,000Hz c - ANSWER = root (bulk modulus/density) or =stiffness/density bulk modulus - ANSWER stress/strain I - ANSWER = P/a P - ANSWER = E/T Amplitude - ANSWER maximum deviat...
    (0)
  • $11.99
  • + learn more
Sonography Canada Core Review Exam 2023.
  • Sonography Canada Core Review Exam 2023.

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • Sonography Canada Core Review Exam 2023. f - ANSWER v/wavelength frequency - ANSWER number of cycles per second T - ANSWER 1/f Period - ANSWER length of time for one cycle 1540 m/s - ANSWER speed of sound in soft tissue infrasound - ANSWER <20Hz audible sound - ANSWER 20Hz-20,000Hz ultrasound - ANSWER >20,000Hz c - ANSWER = root (bulk modulus/density) or =stiffness/density bulk modulus - ANSWER stress/strain I - ANSWER = P/a P - ANSWER = E/T Amplitude - ANSWER maximum deviat...
    (0)
  • $11.99
  • + learn more
Sonography Canada Core Review Questions With Complete Solutions
  • Sonography Canada Core Review Questions With Complete Solutions

  • Exam (elaborations) • 17 pages • 2023
  • Available in package deal
  • f - v/wavelength frequency - number of cycles per second T - 1/f Period - length of time for one cycle 1540 m/s - speed of sound in soft tissue infrasound - <20Hz audible sound - 20Hz-20,000Hz ultrasound - >20,000Hz c - = root (bulk modulus/density) or =stiffness/density bulk modulus - stress/strain I - = P/a P - = E/T Amplitude - maximum deviation from normal A - = max-normal A^2 - proportional to intensity and power PRP - = 1/PRF line tim...
    (0)
  • $12.99
  • + learn more
ARDMS – SPI Exam Questions With Verified And Updated Solutions.
  • ARDMS – SPI Exam Questions With Verified And Updated Solutions.

  • Exam (elaborations) • 12 pages • 2024
  • ARDMS – SPI Exam Questions With Verified And Updated Solutions. What type of wave is a sound wave? - answerlongitudinal, mechanical molecules of the medium vibrate at 90 degrees to the direction of the traveling wave - answertransverse wave what is the range of audible sound? - answer20 Hz to 20 kHz portion of a cycle where the molecules are pushed closer together - answercompression portion of a cycle where the molecules spread farther apart - answerrarefaction what are the three prim...
    (0)
  • $12.49
  • + learn more
Sonography Canada - Core Exam 114 Questions and Answers A+ Score.
  • Sonography Canada - Core Exam 114 Questions and Answers A+ Score.

  • Exam (elaborations) • 12 pages • 2024
  • Available in package deal
  • Sonography Canada - Core Exam Questions and Answers A+ Score. what is the I SPPA for mechanical bioeffects? - ANSWER 190W/cm^2 what is the I SPTA for thermal bioeffects? - ANSWER 720mW/cm^2 recommended MI for fetal scanning - ANSWER MI < 1.9 recommended TI for fetal scanning - ANSWER TI < 0.7 after what fetal age is safe to use PW doppler? - ANSWER 14 weeks what does ALARA stand for - ANSWER as low as reasonably achievable frequency - ANSWER # of cycles/second f = 1/p period - ANS...
    (0)
  • $12.99
  • + learn more
SPI Exam Review Questions And Answers (Updated And Verified)
  • SPI Exam Review Questions And Answers (Updated And Verified)

  • Exam (elaborations) • 44 pages • 2024
  • Available in package deal
  • SPI Exam Review Questions And Answers (Updated And Verified) Ultrasound imaging type in which pulses are reflected and used to produce a display - answerpulsed wave brightness of the dots on image - answeramplitude round-trip travel time per cm in soft tissue - answer13 microseconds A line produced on a display that represents ultrasonic echoes returning from the body. A sonographic image is composed of many such lines. - answerscan line Type of image presented in a rectangular format. ...
    (0)
  • $14.49
  • + learn more
Sonography Canada - Core Exam 114 Questions and Answers A+ Score.
  • Sonography Canada - Core Exam 114 Questions and Answers A+ Score.

  • Exam (elaborations) • 12 pages • 2024
  • Available in package deal
  • Sonography Canada - Core Exam 114 Questions and Answers A+ Score. what is the I SPPA for mechanical bioeffects? - ANSWER 190W/cm^2 what is the I SPTA for thermal bioeffects? - ANSWER 720mW/cm^2 recommended MI for fetal scanning - ANSWER MI < 1.9 recommended TI for fetal scanning - ANSWER TI < 0.7 after what fetal age is safe to use PW doppler? - ANSWER 14 weeks what does ALARA stand for - ANSWER as low as reasonably achievable frequency - ANSWER # of cycles/second f = 1/p period -...
    (0)
  • $11.49
  • + learn more