Pjm practice - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Pjm practice? On this page you'll find 88 study documents about Pjm practice.
Page 3 out of 88 results
Sort by
-
PJM Practice questions With Explanation of Answers.
- Exam (elaborations) • 20 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
A Heavy Load Voltage Schedule Warning is typically issued ___ prior to actual implementation. - correct answer c. 4 hours 
 
The following would be considered non-critical plant load (Select 2) - correct answer A. Office Area Air Conditioners 
C. Lighting 
 
During a Cold Weather Alert, PJM will take which of the actions - correct answer D. Assume an unavailability rate for schedule generation 
 
When PJM issues a High System Voltage Message, the GO should have its units operate at: - correct an...
-
PJM Generation Dispatcher Exam Practice Questions and Answers
- Exam (elaborations) • 5 pages • 2024
-
- $10.49
- + learn more
PJM Generation Dispatcher Exam Practice Questions and Answers
-
PJM Practice Exam 2019 Questions & Answers
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
PJM Practice Exam 2019 Questions & Answers 
 
 
Real time transmission constraints or contingencies may be alleviated with generators operating________. A. below 60 Hz. B. on a new price curve. C. on a new cost curve. D. off cost (out of merit). - ANSWER-off cost (out of merit) 
 
What is the minimum size for a solar park to be required to have real and reactive power 
telemetry? A. 1 MW. B. 3 MW C. 5 MW D. 7 MW - ANSWER-3 MW 
 
PJM calls for which of the following to recover the ACE so that ti...
-
PJM Practice Exam | Questions and Correct Answers | Latest Update 2024/2025 | 100% Pass
- Exam (elaborations) • 9 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
PJM Practice Exam | Questions 
and Correct Answers | Latest 
Update 2024/2025 | 100% Pass 
Real time transmission constraints or contingencies may be alleviated 
with generators operating 
off cost (out of merit) 
- 
what is the minimum size for a solar park to be required to have real 
and reactive power? 
3 MW 
- 
PJM calls for which of the following to recover the ACE so that tie line 
schedules are maintained? 
synchronized reserves 
- 
If not cancelled by PJM, the minimum generation alert e...
-
PJM Practice Exam | Questions & 100% Correct Answers (Verified) | Latest Update | Grade A+
- Exam (elaborations) • 12 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Real time transmission constraints or contingencies may be alleviated with generators 
operating________. A. below 60 Hz. B. on a new price curve. C. on a new cost curve. 
D. off cost (out of merit). 
: off cost (out of merit) 
What is the minimum size for a solar park to be required to have real and reactive 
power 
telemetry? A. 1 MW. B. 3 MW C. 5 MW D. 7 MW 
: 3 MW 
PJM calls for which of the following to recover the ACE so that tie line schedules are 
maintained? A. instantaneous reserve...
And that's how you make extra money
-
PJM Generation Dispatcher Exam Practice Questions & Answers 2024
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $7.99
- + learn more
PJM Generation Dispatcher Exam Practice Questions & Answers 2024 
 
 
An EXCITER on a traditional generator does what? - ANSWER-Voltage regulation (AVR) if you change the excitation current, you change the voltage. 
 
ECO Min, ECO Max, and EMERG Max are genrator _________________. - ANSWER-Limits 
 
When synchronizing to the interconnection, what needs to be synchronized? - ANSWER-Frequency, Voltage, and phase angle. 
 
GMD (GeoMagnetic Disturbance) procedure is implemented when? - ANSWER-10A or...
-
PJM Generation Dispatcher Exam Practice Questions and Answers
- Exam (elaborations) • 7 pages • 2024
-
- $11.49
- + learn more
PJM Generation Dispatcher Exam 
Practice Questions and Answers 
An EXCITER on a traditional generator does what? - Correct Answer ️️ -Voltage 
regulation (AVR) if you change the excitation current, you change the voltage. 
ECO Min, ECO Max, and EMERG Max are genrator _________________. - Correct 
Answer ️️ -Limits 
When synchronizing to the interconnection, what needs to be synchronized? - Correct 
Answer ️️ -Frequency, Voltage, and phase angle. 
GMD (GeoMagnetic Disturbance) procedu...
-
PJM Practice Exam |169| Questions with 100% Correct Answers | Verified | Latest Update 2024
- Exam (elaborations) • 20 pages • 2024
-
- $12.99
- + learn more
PJM Practice Exam |169| Questions with 100% Correct Answers | Verified | Latest Update 2024
-
PJM Practice Exam 2024 with 100% correct answers
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
Real time transmission constraints or contingencies may be alleviated with generators operating________. A. below 60 Hz. B. on a new price curve. C. on a new cost curve. D. off cost (out of merit). - correct answer off cost (out of merit) 
 
What is the minimum size for a solar park to be required to have real and reactive power 
telemetry? A. 1 MW. B. 3 MW C. 5 MW D. 7 MW - correct answer 3 MW 
 
PJM calls for which of the following to recover the ACE so that tie line schedules are maintain...
-
PJM Generation Dispatcher Exam Practice Questions with Correct Answers
- Exam (elaborations) • 6 pages • 2024
- Available in package deal
-
- $8.99
- + learn more
PJM Generation Dispatcher Exam Practice Questions with Correct Answers 
An EXCITER on a traditional generator does what? - Correct Answer Voltage regulation (AVR) if you change the excitation current, you change the voltage. 
 
ECO Min, ECO Max, and EMERG Max are genrator _________________. - Correct Answer Limits 
 
When synchronizing to the interconnection, what needs to be synchronized? - Correct Answer Frequency, Voltage, and phase angle. 
 
GMD (GeoMagnetic Disturbance) procedure is impleme...
Did you know that on average a seller on Stuvia earns $82 per month selling study resources? Hmm, hint, hint. Discover all about earning on Stuvia