Electrode impedance is - Study guides, Class notes & Summaries

Looking for the best study guides, study notes and summaries about Electrode impedance is? On this page you'll find 433 study documents about Electrode impedance is.

Page 3 out of 433 results

Sort by

CNIM APPARENTLY ON THE ACTUAL TEST EXAM |VERIFIED|ACCURATE ANSWERS
  • CNIM APPARENTLY ON THE ACTUAL TEST EXAM |VERIFIED|ACCURATE ANSWERS

  • Exam (elaborations) • 39 pages • 2024
  • Available in package deal
  • CNIM APPARENTLY ON THE ACTUAL TEST EXAM CNIM APPARENTLY ON THE ACTUAL TEST EXAM |VERIFIED|ACCURATE ANSWERS An increase in stimulation intensity causes a linear increase of which of the following SSEP components? 1. N20 2. N45 3. P31 4. P37 - Accurate Answer3. P31 Epidural electrodes are made of platinum because 1. It is the most durable metal 2. It is the lowest impedance metal 3. The chance of allergic reaction is eliminated 4. Other metals may become toxic when currents are a...
    (0)
  • $14.99
  • + learn more
CNIM TEST QUESTIONS AND ANSWERS
  • CNIM TEST QUESTIONS AND ANSWERS

  • Exam (elaborations) • 25 pages • 2023
  • An increase in stimulation intensity causes a linear increase of which of the following SSEP components? 1. N20 2. N45 3. P31 4. P37 - Answer- 3. P31 Epidural electrodes are made of platinum because 1. It is the most durable metal 2. It is the lowest impedance metal 3. The chance of allergic reaction is eliminated 4. Other metals may become toxic when currents are applied - Answer- 4. Other metals may become toxic when currents are applied During a median nerve preoperative study, ...
    (0)
  • $12.49
  • + learn more
RPSGT EXAM MOCK QUESTIONS WITH COMPLETE SOLUTIONS GRADED A+
  • RPSGT EXAM MOCK QUESTIONS WITH COMPLETE SOLUTIONS GRADED A+

  • Exam (elaborations) • 32 pages • 2024
  • Available in package deal
  • _________defined as conjunction with initial deflection >500msec - Answer-Slow rolling eye movements _____is the most powerful zeitgeber and regulates the circadian system. - Answer-light ____measured from trough to trough - Answer-duration A bipolar derivation utilizes which of the following? a. One electrode that overlies an electrically active area b. Two electrodes that overlie an electrically active area c. One electrode over an active and one over an inactive area d. Two electrod...
    (0)
  • $7.99
  • + learn more
CNIM Exam Questions and Answers 2023
  • CNIM Exam Questions and Answers 2023

  • Exam (elaborations) • 38 pages • 2023
  • Available in package deal
  • Which of the following would best enhance resolution of evoked potential waveforms? - Increase number of averaged stimuli What is the typical MINIMUM common mode rejection ratio of in-phase signals recommended for evoked potential instruments? - 10,000:1 Which of the following cranial nerves is most at risk during acoustic neuroma surgery? - CN VII The impedance of cup electrodes is: - Lower than needle electrodes because of their size Amplitude of an evoked potential depends on which of...
    (0)
  • $12.00
  • + learn more
2024 CNIM Exam New Full Exam Questions and Answers ( Included ) 100% Correct
  • 2024 CNIM Exam New Full Exam Questions and Answers ( Included ) 100% Correct

  • Exam (elaborations) • 18 pages • 2024
  • 2024 CNIM Exam New Full Exam Questions and Answers ( Included ) 100% Correct 1. Which of the following would best enhance resolution of evoked potentialwaveforms? Answer: Increase number of averaged stimuli 2. What is the typical MINIMUM common mode rejection ratio of in-phasesignals recommended for evoked potential instruments? Answer: 10,000:1 3. Which of the following cranial nerves is most at risk during acoustic neuro-ma surgery? Answer: CN VII 4. The impedance of cup electrodes ...
    (0)
  • $11.49
  • + learn more
BOOK 2 CLTM actual exam questions and answers
  • BOOK 2 CLTM actual exam questions and answers

  • Exam (elaborations) • 66 pages • 2024
  • Available in package deal
  • verbal name and dob only what are the patient identifiers used if the patient is obtunded hospital appointed intepreter only if the patient does not speak english who is qualified to serve as an interpreter hep, b, hep c, hiv what are some blood borne health care associated infections disconnect patient if you get a shock from the equipment what step should be completed first ? <10nA whats the impedance for strips and grids? 10 uA rms max allowable cha...
    (0)
  • $14.99
  • + learn more
CNIM apparently on the actual test questions WITH COMPLETE SOLUTION ALREADY PASSED!!2024 CNIM
  • CNIM apparently on the actual test questions WITH COMPLETE SOLUTION ALREADY PASSED!!2024 CNIM

  • Exam (elaborations) • 108 pages • 2024
  • Available in package deal
  • An increase in stimulation intensity causes a linear increase of which of the following SSEP components? 1. N20 2. N45 3. P31 4. P37 - answer 3. P31 Epidural electrodes are made of platinum because 1. It is the most durable metal 2. It is the lowest impedance metal 3. The chance of allergic reaction is eliminated 4. Other metals may become toxic when currents are applied - answer 4. Other metals may become toxic when currents are applied During a median nerve preoperative study, a pa...
    (0)
  • $7.99
  • + learn more
IBHRE Review Exam || With Questions & Answers (100% Verified)
  • IBHRE Review Exam || With Questions & Answers (100% Verified)

  • Exam (elaborations) • 18 pages • 2024
  • Available in package deal
  • IBHRE Review Exam || With Questions & Answers (100% Verified) IBHRE Review Exam || With Questions & Answers (100% Verified) Lithium iodine battery V? - ANSWER - 2.8V- not used for ICDs due to low peak power. Qmr Lithium Iodine/ silver V? - ANSWER - 3.2V Qhr- used for ICDS Which is an example of a closed loop sensor? - ANSWER - myocardial contractility and O2 stat Primary Sensor - ANSWER - detects changes in normal physiologic responses Secondary - ANSWER - detects internal change...
    (0)
  • $11.99
  • + learn more
ABRET (3) Questions with verified answers.
  • ABRET (3) Questions with verified answers.

  • Exam (elaborations) • 4 pages • 2024
  • Available in package deal
  • What type of montage is shown in this sample? correct answers Referential Montage Which montage would best display the amplitude of a left temporal spike? correct answers Left temporal to the contralateral ear Referential recording is most appropriate for measuring? correct answers Voltage How can a defective electrode be identified? correct answers Placing a bad electrode with high impedance into a pin position with working non reference electrode will result high impedance To confi...
    (0)
  • $9.69
  • + learn more
CNIM Exam Questions and Answers [apparently on the actual test] 2023
  • CNIM Exam Questions and Answers [apparently on the actual test] 2023

  • Exam (elaborations) • 44 pages • 2023
  • Available in package deal
  • An increase in stimulation intensity causes a linear increase of which of the following SSEP components? 1. N20 2. N45 3. P31 4. P37 - 3. P31 Epidural electrodes are made of platinum because 1. It is the most durable metal 2. It is the lowest impedance metal 3. The chance of allergic reaction is eliminated 4. Other metals may become toxic when currents are applied - 4. Other metals may become toxic when currents are applied During a median nerve preoperative study, a patient has disc...
    (0)
  • $12.00
  • + learn more