1- A hydrotest is being conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 psig. At the end of the test, the pressure must be at least: -C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design temperature of 950 
degrees F. The flange material is ASTM A217 gr.C12 - B. 375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness is 0.218" and 
the corrosion allowanc...
-
API 570 Open Book Exam Questions and Answers 100% Pass
- Exam (elaborations) • 8 pages • 2024
-
- $12.49
- + learn more
API 570 Open Book Exam Questions and 
Answers 100% Pass 
A hydrotest is being conducted on an underground line as a substitute for the external 
inspection. The test pressure is 200 psig. At the end of the test, the pressure must be at 
least: - Answer- C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design 
temperature of 950 degrees F. The flange material is ASTM A217 gr.C12 - Answer- B. 
375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B mater...
-
API 570 - Open Book - Practice Exam Questions with 100% Correct Answers | Latest Version 2024 | Expert Verified | Ace the Test
- Exam (elaborations) • 23 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
API 570 - Open Book - Practice Exam 
Questions with 100% Correct Answers | 
Latest Version 2024 | Expert Verified | 
Ace the Test
-
API 570 Open Book Exam with Questions & Answers| Pass Guaranteed
- Exam (elaborations) • 8 pages • 2024
-
- $9.49
- + learn more
- A hydrotest is being conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 psig. At the end of the test, the pressure must be at least: - C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design temperature of 950 
degrees F. The flange material is ASTM A217 gr.C12 - B. 375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness is 0.218" and 
the corrosion allowanc...
-
API 570 Open Book Exam (ANSWERED)
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
1- A hydrotest is being conducted on an underground line as a substitute for the external inspection. The test pressure is 200 psig. At the end of the test, the pressure must be at least: - Correct Answer C.190 psig 
 
2- Determine the maximum allowed pressure for a class 300 flange that has a design temperature of 950 degrees F. The flange material is ASTM A217 gr.C12 - Correct Answer B. 375 psig 
 
3- An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness i...
And that's how you make extra money
-
API 570 - Open Book - Practice Exam 2024: Q’s And A’s
- Exam (elaborations) • 13 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
API 570 - Open Book - Practice Exam 2024: Q’s And A’s
-
API 570 BUNDLED EXAMS
- Package deal • 13 items • 2024
-
- $31.40
- + learn more
Exam (elaborations)
API 570 - OPEN BOOK - PRACTICE EXAM 2024

2
Exam (elaborations)
API 570 CLOSED BOOK TEST

3
Exam (elaborations)
API 570 DEFINITIONS QUESTIONS & ANSWERS

4
Exam (elaborations)
API 570 EXAM (FULL) QUESTIONS AND ANSWERS

5
Exam (elaborations)
API 570 EXAM QUESTIONS AND ANSWERS

6
Exam (elaborations)
API 570 EXAM QUESTIONS AND ANSWE
-
API 570 - Open Book - Practice Exam 2024 Already Passed
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
API 570 - Open Book - Practice Exam 
 
2024 Already Passed 
 
A Hydrotest is conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 Psig. At the end of the test, the pressure must be at least - API 570 9.8.6 
190 Psig. 
Determine the maximum allowed pressure for a Class 300 flange that has a design temperature 
of 950 °F. The flange material is ASTM A217 Gr. C12 - B16.5 Table 1.1-1 
375 Psig. 
An 8 NPS pipe is being replaced with A106 gr. B mater...
-
API 570 - OPEN BOOK - PRACTICE EXAM 2024
- Exam (elaborations) • 10 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
API 570 - OPEN BOOK - PRACTICE EXAM 2024
-
API 570 - Open Book - Exam Questions With Revised Correct Detailed Answers Guarantee Pass
- Exam (elaborations) • 18 pages • 2024
- Available in package deal
-
- $11.34
- + learn more
API 570 - Open Book - Exam 
Questions With Revised Correct 
Detailed Answers 
Guarantee Pass 
1) What is the maximum allowed hydrotest pressure for piping with class 300 
flanges that are made of ASTM 182 Gr. F316 Material? The Design 
Temperature is 600 °F - ASME B16.5: 2.6, Tables 1.1-1 & 2-2.2c 
1100 Psig. 
2) What is the required preheat temperature for an A106 Gr. B pipe with 
carbon content less than 0.2% and has a wall thickness of 0.500"? - ASME 
B31.3: Table 330.1.1 