1- A hydrotest is being conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 psig. At the end of the test, the pressure must be at least: -C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design temperature of 950 
degrees F. The flange material is ASTM A217 gr.C12 - B. 375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness is 0.218" and 
the corrosion allowanc...
-
API 570 Open Book Exam with Questions & Answers| Pass Guaranteed
- Exam (elaborations) • 8 pages • 2024
-
- $9.49
- + learn more
- A hydrotest is being conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 psig. At the end of the test, the pressure must be at least: - C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design temperature of 950 
degrees F. The flange material is ASTM A217 gr.C12 - B. 375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness is 0.218" and 
the corrosion allowanc...
-
API 570 Open Book Exam Questions and Answers 100% Pass
- Exam (elaborations) • 8 pages • 2024
-
- $12.49
- + learn more
API 570 Open Book Exam Questions and 
Answers 100% Pass 
A hydrotest is being conducted on an underground line as a substitute for the external 
inspection. The test pressure is 200 psig. At the end of the test, the pressure must be at 
least: - Answer- C.190 psig 
2- Determine the maximum allowed pressure for a class 300 flange that has a design 
temperature of 950 degrees F. The flange material is ASTM A217 gr.C12 - Answer- B. 
375 psig 
3- An 8 NPS pipe is being replaced with A106 gr. B mater...
-
API 570 - Open Book - Practice Exam Questions with 100% Correct Answers | Latest Version 2024 | Expert Verified | Ace the Test
- Exam (elaborations) • 23 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
API 570 - Open Book - Practice Exam 
Questions with 100% Correct Answers | 
Latest Version 2024 | Expert Verified | 
Ace the Test
Want to regain your expenses?
-
API 570 - Open Book - Practice Exam 2024: Q’s And A’s
- Exam (elaborations) • 13 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
API 570 - Open Book - Practice Exam 2024: Q’s And A’s
-
API 570 BUNDLED EXAMS
- Package deal • 13 items • 2024
-
- $31.40
- + learn more
Exam (elaborations)
API 570 - OPEN BOOK - PRACTICE EXAM 2024

2
Exam (elaborations)
API 570 CLOSED BOOK TEST

3
Exam (elaborations)
API 570 DEFINITIONS QUESTIONS & ANSWERS

4
Exam (elaborations)
API 570 EXAM (FULL) QUESTIONS AND ANSWERS

5
Exam (elaborations)
API 570 EXAM QUESTIONS AND ANSWERS

6
Exam (elaborations)
API 570 EXAM QUESTIONS AND ANSWE
-
API 570 Open Book Exam (ANSWERED)
- Exam (elaborations) • 8 pages • 2024
- Available in package deal
-
- $10.99
- + learn more
1- A hydrotest is being conducted on an underground line as a substitute for the external inspection. The test pressure is 200 psig. At the end of the test, the pressure must be at least: - Correct Answer C.190 psig 
 
2- Determine the maximum allowed pressure for a class 300 flange that has a design temperature of 950 degrees F. The flange material is ASTM A217 gr.C12 - Correct Answer B. 375 psig 
 
3- An 8 NPS pipe is being replaced with A106 gr. B material. The pipe retirement thickness i...
-
API 570 - Open Book - Practice Exam 2024 Already Passed
- Exam (elaborations) • 22 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
API 570 - Open Book - Practice Exam 
 
2024 Already Passed 
 
A Hydrotest is conducted on an underground line as a substitute for the external inspection. The 
test pressure is 200 Psig. At the end of the test, the pressure must be at least - API 570 9.8.6 
190 Psig. 
Determine the maximum allowed pressure for a Class 300 flange that has a design temperature 
of 950 °F. The flange material is ASTM A217 Gr. C12 - B16.5 Table 1.1-1 
375 Psig. 
An 8 NPS pipe is being replaced with A106 gr. B mater...
-