Field tech
Liberty University
All 9 results
Sort by
-
ACI Concrete Field Testing Technician - Grade 1 (18) Exam Questions And Answers Combined Solutions
- Package deal • 5 items • 2024
-
- $22.49
- + learn more
ACI Concrete Field Testing Technician - Grade 1 (18) Exam Questions And Answers Combined Solutions 

-
ACI Concrete Field Testing Technician - Grade I Exam Questions And Answers
- Exam (elaborations) • 5 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
ACI Concrete Field Testing Technician - Grade I Exam Questions And Answers 
 
The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - ANS 77mm /3in. 
 
The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] through a range of __. - ANS 0.5 C / +-1F / 0-50 Degrees C 
 
The temp. measuring device shall be verified __, or...
-
ACI- Concrete Field-Testing Technician - Grade 1 Exam Questions And Answers
- Exam (elaborations) • 30 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
ACI- Concrete Field-Testing Technician - Grade 1 Exam Questions And Answers 
 
 
Q1. Start molding specimens for strength tests within 30 minutes after fabricating the composite sample. 
 
A. True 
B. False - ANS B. False 
 
 ASTM C172 -Para (4.1.2) - Start molding. 
specimens for strength tests within 15 min after fabricating the 
composite sample. 
 
Q2. The maximum allowable time between obtaining the first and last portions of the composite sample may not exceed 5 minutes. 
 
A. True 
B....
-
ACI Concrete Field Testing Technician - Grade 1 (18) Exam Questions And Answers
- Exam (elaborations) • 21 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
ACI Concrete Field Testing Technician - Grade 1 (18) Exam Questions And Answers 
 
ASTM C1064 - ANS Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement Concrete 
 
The end of the temperature sensing portion of the temperature measuring device shall be submerged a minimum of ____ into the freshly mixed concrete. - ANS 3 inches [75 mm] 
 
C1064, Sec. 8.1 
 
The temperature measuring device shall have a capacity of measuring the temperature of freshly mixed concrete to ± _...
-
ACI Certification - Concrete Field Testing Technician - Grade 1 - Test Sample Written Exam Questions - CP-1(17)
- Exam (elaborations) • 2 pages • 2024
- Available in package deal
-
- $8.49
- + learn more
ACI Certification - Concrete Field Testing Technician - Grade 1 - Test Sample Written Exam Questions - CP-1(17) 
 
 
 
The Method of determining air content of concrete containing lightweight aggregate is the pressure method. True or False? - ANS False 
 
When making a test cylinder from concrete being used in construction, the field technician must also measure the slump of the concrete. True or False? - ANS True 
 
While the technician is checking the slump of the concrete, there is a dec...
Too much month left at the end of the money?
-
ACI Concrete Field Testing Technician- Grade I Exam Questions And Answers
- Exam (elaborations) • 11 pages • 2024
- Available in package deal
-
- $13.49
- + learn more
ACI Concrete Field Testing Technician- Grade I Exam Questions And Answers 
 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. - ANS 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. - ANS 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
 
The temperature measuring ...
-
ACI Certification Tests Bundle Set
- Package deal • 19 items • 2023
-
- $40.99
- 1x sold
- + learn more
ACI Certification Tests Bundle Set
-
ACI Concrete Field Testing Technician- Grade I questions with correct answers
- Exam (elaborations) • 17 pages • 2023
- Available in package deal
-
- $13.99
- 4x sold
- + learn more
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete. Answer 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of _____. Answer 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C] 
 
The temperature measuring device shall be calibrated _____, or whenever there is a question of _____. Answer...
-
Final Exam: Progression: Field Tech III - IV Final EXAM 130+ QUESTIONS AND VERIFIED ANSWERS 2023 LATEST GUIDE.
- Exam (elaborations) • 11 pages • 2023
-
- $10.99
- + learn more
Final Exam: Progression: Field Tech III - IV Final EXAM 130+ 
QUESTIONS AND 
VERIFIED ANSWERS 2023 
LATEST GUIDE. 
1. The open system interconnection reference model (OSI/R<) Network layer 
serves which primary function?: It uses layer 3 addresses to create multiple 
routed networks 
2. The address 68.56.189.17 belongs to which internet protocol IP class?: - 
Class A 
3. What happens to a datagram sent by a higher level protocol to a 127.x.y.z 
address?: The datagram loops back inside the hos...
$6.50 for your textbook summary multiplied by 100 fellow students... Do the math: that's a lot of money! Don't be a thief of your own wallet and start uploading yours now. Discover all about earning on Stuvia