NEC Article ______ defines breakers and fuses. - answer According to NEC Article 100,
a device that opens and closes a circuit by nonautomatic means automatically closes
for a predetermined overcurrent.
Annex _____ of NEC covers conduit fill. - answer Annex C of NEC covers conduit and
tubing fill for conductors and fixture wire fill.
NEMA stands for National Electrical Manufacturers Association - answer True - NEMA
is the acronym for National Electrical Manufacturers Association.
What does it mean when a receptacle has "NEMA 5-20R" on it? - answer A receptacle
with NEMA 5-20R on it has an amperes rating of 20, will take a NEMA-5-15P or NEMA-
5-20P plug, and has a voltage rating of 125.
NEC Tables 310-10 through 310-21 provide information on. - answer The sizes of
copper and aluminum wire, as well as the coating of wire that has fewer than three
current carrying wires in a cable or conduit or that is buried in the earth.
Which NEC tables(s) cover(s) the fill of metal boxes? - answerThe fill of metal boxes
appears in NEC Tables 314.6 A and B.
Which NEC articles cover the installation requirements for RMC, IMC, and EMT? -
answerNEC Articles 342, 344, and 358 outline the installation requirements of RMC,
IMC, and EMT.
IN NEC 2008, what does Table 370.6A cover? - answerShows in two columns
(milimeters and inches), how many wires in trade size you can place in a box.
What NEC table would you go to to find trade size of conduit and raceway size? -
answerChapter 9, Table 4 outlines trade size of conduit as well as raceway size.
NEC Articles _____ and _____ covers metallic and non-metallic raceways in buildings. -
answerNEC Article 386 covers metallic or metal raceway; NEC Article 388 covers PVC
pipe.
The Panel Board requirements for Application in Construction appear in NEC Article? -
answerNEC Article 408 covers panel board applications.
,The smaller kitchen counter requiring a receptacle is _____ inches. - answerA 12in.
counter requires a receptacle because it holds small appliances.
What new code is needed for protection in all habitable spaces? - answerAccording to
new codes, ARC fault protection is needed many additional parts of the house.
A 12-foot hallway requires one receptacle to meet code. (True or False) - answerTrue,
One is required, Two are suggested.
NEC Article 100 is dedicated to? - answerDefinitions
The main ground on a service is a(n) _____. - answerGround Rod
What does NEC Section 250-28A require? - answerA main bonding jumper and a
system bonding jumper.
NEC section 250-28A provides information on what material can be used for a main
bonding jumper. (True or False) - answerTrue
A bonding screw is what color? - answerA bonding screw is green.
A subpanel requires a bonding screw? (True or False) - answerFalse, A bonding screw
is unneeded in a subpanel.
Name the methods of sizing bonding jumpers outlined in NEC Section 250-28D. -
answer1. Bonding jumper is sized not less than 12.5% of the largest phase conductor.
2. Based on the largest ungrounded service conductor.
3. Based on the largest sum of the service conductors.
Which NEC reference identifies wire sizing and the temperature a wire can handle in
amps? - answerNEC Tables Annex C1 and C2 identify both wire sizing and the
temperature a wire can handle in amps.
Define a grounding system according to NEC. - answerA gounding system is connected
to the ground or to a conductive body that extends the ground connection.
What is the topic of NEC Section 250-122? - answerIs dedicated to the sizes of the
grounding conductor
What is the NEC definition of a circuit breaker? - answerA device designed to trip when
an overcurrent is detected.
, NEC Section 300-13 provides information on? - answerMechanical and Electrical
continuity conductors.
What is the subject of NEC Section 250-2D? - answerBonding jumpers
______ are the subject of NEC Section 680-20. - answerElectrical installations at
permanently installed pools.
Which NEC Section covers equipment grounding conductors. - answerNEC Section
250-118
Which NEC sections covers identification of equipment grounding conductors? -
answerNEC Section 250-119 1-14
Which NEC Section covers ground terminal identification. - answerNEC Section 250-
126
Bonding is the establishment of ______ connection between metal parts. -
answerReliable
NEC Section 250-134 provides information on what topic? - answerEquipment fastened
or connection between metal parts.
Equipment grounding conductor _____ is (are) discussed in NEC Section 250-130. -
answerConnections
NEC Section 250-118 states that a grounded conduct must run _____ flexible conduit. -
answerinside
NEC Section _____ oversees bonding of flexible type conduit. - answerNEC Section
250.118(5)
Which NEC article covers cable trays? - answerNEC Article 392
What is the proper procedure for bonding a motor conduit with metal flex? - answerA
bonding jumper should be installed inside or outside raceway within 6ft. of attachment.
(NEC 250.118)
Threaded pipe can be used for bonding purposes? (True or False) - answerTrue (NEC
250.92B)
Shoulder fittings with locknuts are allowable as bonding devices? (True or False) -
answerTrue (NEC 250.92B)
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $17.99. You're not tied to anything after your purchase.