100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
OIL BURNER LICENSE EXAM 2024| 250 ACTUAL EXAM QUESTIONS WITH 100% CORRECT ANSWERS| RATED A+ $17.99   Add to cart

Exam (elaborations)

OIL BURNER LICENSE EXAM 2024| 250 ACTUAL EXAM QUESTIONS WITH 100% CORRECT ANSWERS| RATED A+

 0 view  0 purchase
  • Course
  • OIL BURNER LICENSE
  • Institution
  • OIL BURNER LICENSE

OIL BURNER LICENSE EXAM 2024| 250 ACTUAL EXAM QUESTIONS WITH 100% CORRECT ANSWERS| RATED A+

Preview 4 out of 34  pages

  • November 18, 2024
  • 34
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • OIL BURNER LICENSE
  • OIL BURNER LICENSE
avatar-seller
NURSINGEXAMS
OIL BURNER LICENSE EXAM 2024| 250 ACTUAL EXAM
QUESTIONS WITH 100% CORRECT ANSWERS| RATED A+

What is the first thing a tech should do when arriving at a no combustion call? - RIGHT CHOICE✔ Ask

how many times the customer reset the unit.


What is the best long-term solution for preventing a clogged nozzle? - RIGHT CHOICE✔ -Remove any

underground storage tanks.


-Install a quality oil filter.


-Cut the suction line 10" above the tank outlet to prevent sludge.

Hot water and steam valves are interchangeable. - RIGHT CHOICE✔

False

When in the presence of a flame, a cad cell normally reads. - RIGHT CHOICE✔ 300-1000 ohms


If a pump is used to bring oil to a level higher than the tank, an oil safety valve is required. - RIGHT

CHOICE✔ True


On a call where a hydronic heat system is putting out too much heat on the stack, the issue may be. -

RIGHT CHOICE✔ -Too much draft.


-Not enough combustion air in the equipment room.


-Air leakage into chamber.


A high CO2 reading is caused by.. - RIGHT CHOICE✔ Incomplete combustion


An often overlooked cause of a high CO2 reading is.. - RIGHT CHOICE✔ Not enough combustion air in

the equipment room.


When multiple pumps are wired together in a heating system, they should be wired in.. - RIGHT

,CHOICE✔ parallel


In a series circuit.. - RIGHT CHOICE✔ Current has one path.


When 2 burners are connected to the same chimney.. - RIGHT CHOICE✔ Sufficient draft must be

obtained to operate both units.


The ignition transformer is located.. - RIGHT CHOICE✔ In the primary control.

When safeties are wired in series one safety will affect the operation of the others. - RIGHT CHOICE✔

True


A stack switch is no longer allowed to be installed or replaced because.. - RIGHT CHOICE✔ It's safety

cutout time is higher than what is now required.


What is a power venter and what does it do? - RIGHT CHOICE✔ An electrical device that sends fluid

gases into the chimney connector.


A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening for

combustion air? - RIGHT CHOICE✔ 140"


The difference between an adjustable flame retention burner and a fixed flame retention burner is? -

RIGHT CHOICE✔ Air inlets can be adjusted




Ignitor position can be adjusted




Fuel can be adjusted

,Oil tank design, construction, installation and testing shall be in accordance with.. - RIGHT CHOICE✔

527 CMR 9.0


Heat is a form of.. - RIGHT CHOICE✔ Energy


If a burner is operational but the circulator pump isn't running.. - RIGHT CHOICE✔ The pump relay is

not working correctly


A method of dealing with low viscosity/cold temps with #2 oil? - RIGHT CHOICE✔ Increase pump

pressure/ decrease nozzle size


What is needed at the outlet of an oil tank? - RIGHT CHOICE✔ Thermal safety

valve


Where do you obtain an installation permit for oil burners? - RIGHT CHOICE✔


Fire Dept


How many Btu's approximately in 1 gal of #2 fuel oil? - RIGHT CHOICE✔ 140,000

btu's

Solid state ignition is superior to spark because - RIGHT CHOICE✔ It is not affected by reduced voltage


What is an installation? - RIGHT CHOICE✔ The complete setting in place, ready for operation, of an oil

burner appliance together with its accessories and equipment.


How far must a power vent terminate from an opening or window? - RIGHT

CHOICE✔ 4' A pump in a one pipe system that is full of air can be self purged. -

RIGHT CHOICE✔ False List the minimum size of an oil supply line. - RIGHT

CHOICE✔ 3/8"

, A material with electrons so loose it allows voltage to pass with little or no resistance.. - RIGHT CHOICE✔

Is a conductor


If a high limit goes off, what does a low water switch do? - RIGHT CHOICE✔ Maintains water temperature


What is flashpoint an indicator of? - RIGHT CHOICE✔ Minimum temperature oil will ignite but not

continue to burn.


What travels on the inside of the wire? - RIGHT CHOICE✔ Volts


What does readily accessible mean pertaining to oil burning equipment? - RIGHT CHOICE✔ Capable of

being reached easily and quickly for operation, maintenance or inspection.


What is the minimum vent pipe on an oil tank? - RIGHT CHOICE✔ 1 1/4"


What causes corrosion on a flue pipe? - RIGHT CHOICE✔ When the flue pipe is operating below the

dew point temperature.


What are the methods to prevent oil waxing? - RIGHT CHOICE✔ Put additives in the fuel.




Add an oil line heater.




Cut with #1 fuel or kerosene.


What is the maximum tank size allowed inside unenclosed? - RIGHT CHOICE✔ 660 gal


What is the purpose of a delayed oil valve? - RIGHT CHOICE✔ Allows time for the oil pump to get up to

speed.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller NURSINGEXAMS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75759 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart