Where, in any specific case, different sections of this code specify different
materials, methods of construction or other requirements, the
most_________shall govern.
Section R102.1 Answer - restrictive
The purpose of this code is to establish ________ requirements to safeguard
the public safety, health and general welfare.
Section R101.3 Answer - minimum
Where the extent of the reference to a referenced code or standard includes
subject matter that is within the scope of the IRC, the provisions of the
________ shall take precedence.
Section R102.4.2 Answer - IRC
An alternative material or method shall be approved where the proposed
design is _______ and complies with _______of the provisions of the IRC.
Section R104.11 Answer - satisfactory intent
Other than storm shelters, a permit is not required for one story detached
accessory structures, provided that the floor area does not exceed _______
square feet
Section R 105.2 Answer - 200 sq ft
,Compliance with the specific ________ -based provisions of the International
Codes shall be an alternative to the specific requirements of the IRC
Section R104.11 Answer - performance
Fences not over_______ feet high do not require permits
Section R105.2 Answer - 7 ft
A permit is not required for the replacement of branch circuit overcurrent
devices(breakers) of the ________ capacity in the same location (within a
panel)
Section R105.2 Answer - required
Decks not exceeding ______ square feet in area, that are not more than
_______ inches above grade at any point, are not attached to a dwelling, do
not require a permit.
Section R105.2 Answer - 200 sq ft 30in
Where equipment replacements and repairs must be performed in an
emergency situation, the permit application shall be submitted within the
_______ _________ business day.
Section R105.2.1 Answer - next working (to the building official)
An application for a permit for any proposed work shall be deemed to have
been abandoned ___________days after the date of filing.
Section R105.3.2 Answer - 180 (180 days also applies to extensions)
,Before issuing a permit, the building official is __________ to examine or cause
to be examined buildings, structures and sites for which an application has
been filed.
Section R105.9 Answer - authorized
Where the building official issues a permit, the construction documents shall
be approved in writing or by a stamp that states ___________ _________
_________ ___________.
Section R106.3.1 Answer - REVIEWED FOR CODE COMPLIANCE
Final inspection shall be made after the permitted work is ____________ and
prior to ____________.
Section R109.1.6 Answer - complete occupancy
If located in a flood hazard area, the documentation of elevations required in
Section R322.1.10 shall be submitted to the building official prior to the
______________ inspection
Section R109.1.6.1 Answer - final
That which enables a device, an appliance or equipment to be reached by
ready access or by a means that first requires the removal or movement of a
panel, door or similar obstruction.
Section R202 Answer - Access (to)
A finished or unfinished habitable space within a attic
Section R202 Answer - Attic, Habitable
Hot water is water at a temperature greater than ________*F
Section R202 Answer - 120*F
, A wall supporting any vertical load in addition to its own weight is a
___________-_____________ wall
Section R202 Answer - load-bearing
What is the minimum uniformly distributed live load for habitable attics and
attics served with fixed stairs?
Table R301.5 Answer - 30 pounds per square foot
Wood structural panels with a thickness of not less than __________ inch and
a span of not more than _________ feet shall be permitted for opening
protection in windborne debris regions.
Section R301.2.1.2 Answer - 7/16in 8ft
The seismic provisions of the IRC apply to detached one- and two family
dwellings in Seismic Design Categories _______________.
Section R301.2.2 Answer - D0, D1 and D2
For dwellings with fire sprinkler systems, exterior walls with a fire separation
distance less than __________ feet shall have not less than a 1 hour fire-
resistance rating with exposure from the outside.
Table R302.1.(2) Answer - 3 ft
Where an automatic sprinkler system in accordance with Section P2904 is not
provided, the common wall between townhouse units shall be not less than a
_________-hour_________-__________-__________wall assembly.
Section R302.2.2 Answer - 2 hr fire-resistance rated
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller EvaTee. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $27.99. You're not tied to anything after your purchase.