Nicet level 1 Study Guide questions Latest Update Actual Exam from Credible Sources with 150 Questions and Verified Correct Answers Golden Ticket to Guaranteed A+ Verified by Professor$20.49
Add to cart
Nicet level 1 Study Guide questions Latest Update Actual Exam from Credible Sources with 150 Questions and Verified Correct Answers Golden Ticket to Guaranteed A+ Verified by Professor
2 views 0 purchase
Course
Nicet level 1
Institution
Nicet Level 1
Nicet level 1 Study Guide questions Latest Update Actual Exam from Credible Sources with 150 Questions and Verified Correct Answers Golden Ticket to Guaranteed A+ Verified by Professor
Nicet level 1 Study Guide questions Latest
Update 2024-2025 Actual Exam from Credible
Sources with 150 Questions and Verified Correct
Answers Golden Ticket to Guaranteed A+
Verified by Professor
______________ must provide head protection when working in areas where there is a
possible danger of head injury from impact, or from falling or flying objects, or from
electrical shock and burns.
OSHA 1926.100(b)(1) - CORRECT ANSWER: The employer
A 20 X 20' ft room with a 20'ft high ceiling requires at a minimum a ___ ceiling mounted
strobe - CORRECT ANSWER: 30 candela
A 200 ohm resistor draws 2 amps of current when connected to a power source. What
is the voltage applied to the resistor? - CORRECT ANSWER: 400 volts
A 24VDC bell draws 0.8 amps of current and it is located 500'ft from the fire alarm
control panel. According to the manufacturer, the bell will operate with no more than a
10% voltage drop. Assuming a temperature of 70*F, what is the smallest sized, coated
solid copper conductor that shall be used to provide power to the bell?
-Find Chapter 9 table 8 in the NEC, plug ohm values into your equation E = I*R and
solve - CORRECT ANSWER: 12 AWG
A ceiling mounted horn/strobe light was selected to be installed on a 40'ft high ceiling.
Which mounting method best matches NFPA 72 requirements? - CORRECT ANSWER:
Suspended horn/strobe light at or below 30'ft
,A ceiling shall be treated as a smooth celing if the beams project no more than ____
below the ceiling - CORRECT ANSWER: 4"inches
A circuit contains 2 resistors connected in series. When 24VDC are applied to the
circuit, 2.4 amps of current are drawn. What is the total resistance of the circuit?
-R = E/I - CORRECT ANSWER: 10 ohms
A circuit contains three resistors in parallel. There values are R1=300, R2=300 and
R3=300. What is the total resistance of the circuit? - CORRECT ANSWER: 100 ohms
A diode's function is? - CORRECT ANSWER: To only allow current to flow one way
A fire alarm system with a pre-signal feature installed on the protected premises shall be
permitted if ______________.
NFPA 72 - 23.8.1.2.1 - CORRECT ANSWER: approved by the AHJ
A fixed-temperature, non-restorable spot type heat detector shall be tested ____ from
initial installation. - CORRECT ANSWER: 15 years after
A heat detector with a listed spacing of 50'ft will be installed. What spacing shall be used
for a **20'ft** ceiling that is smooth and flat? - CORRECT ANSWER: 32'ft - because
detectors at or above 20'ft shall multiply the listed detector spacing by 0.64.
i.e.(50x0.64=32)
A horn was installed to provide notification for a sleeping area. According to NFPA 72,
what is the minimum sound level, in dB, allowed above average ambient sound level? -
CORRECT ANSWER: 15dB
, A horn will be installed in the hallway of a Holiday Inn (hotel). According to NFPA 72,
what is the minimum mounting height above the finished floor? - CORRECT ANSWER:
90"inches
A parallel circuit has a total circuit current of 2 amps. What is the applied circuit voltage
if total resistance is 6 Ohms?
E=IxR - CORRECT ANSWER: 12 volts
A pressure supervisory signal-initiating device for a dry-pipe sprinkler system shall
indicate ______________.
NFPA 72 - 17.16.2.2.2(A) - CORRECT ANSWER: Both high and low pressure
conditions
A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type
heat detector has been selected that is listed for a 50' maximum spacing between
detectors. According to NFPA 72 how many detectors will be needed to protect this
room?
x = - CORRECT ANSWER: 12
A room measures 60'ft long by 60'ft wide and has a smooth flat ceiling 10'ft high. A spot-
type heat detector with a listed spacing of 30'ft was selected to be installed. According
to NFPA 72, what is the minimum number of detectors required?
x 60/30 = - CORRECT ANSWER: 4
A separate storage battery and separate automatic charger shall be provided for starting
the engine-driven generator and shall ___________________.
NFPA 72 10.6.11.7 - CORRECT ANSWER: not be used for any other purpose
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Tutordiligent. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $20.49. You're not tied to anything after your purchase.