ABYC Systems Certification Exam Review Questions With Detailed Answers 175% - Answer-At what what percentage of nominal working pressure shall the relief valve be set? /.nominal working pressure, not to exceed 80 PSI - Answer-For the pressure reducing valve and check valve installed after a s...

[Show more]

Preview 3 out of 23  pages

  • November 13, 2024
  • 23
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ABYC Systems Certification
  • ABYC Systems Certification
avatar-seller
kartelodoc
ABYC Systems Certification Exam
Review Questions With Detailed
Answers
175% - Answer-At what what percentage of nominal working pressure shall the relief
valve be set?

/.nominal working pressure, not to exceed 80 PSI - Answer-For the pressure reducing
valve and check valve installed after a shore water connection, what is the maximum
allowable pressure?

/.3 PSI or mnfg's maximum, which ever is greater. - Answer-What is the maximum
allowable pressure to which the storage tank and vent system be subjected?

/.True - Answer-Storage tank inlet caps must be retained to prevent loss. T or F?

/.True - Answer-Storage tanks must be equipped with a vent. T or F?

/.True - Answer-Storage tank vent may be used for filling purposes. T or F?

/.At least 1.5X the pressure exerted by the distance from the tank bottom to the deck fill
plate or vent, but not less than 3 PSI. - Answer-What rate of static pressure must a
storage tank withstand?

/.3 PSI - Answer-What is the max pressure that a desalinator can impart to a storage
tank?

/.True - Answer-Each desalinator must be equipped with an automatic shutoff salinity
detector. T or F?

/."For Cold Water Use Only" - Answer-What marking must be on pipe or tubes that are
not capable of handling hot water?

/.125 PSI, 300 PSI - Answer-What is the test pressure for water heater tank 15 gal or
less? over 15 gal but under 120 gal?

/.175 PSI - Answer-What is the max pressure relief valve setting for hot water tanks?

/.210 F - Answer-What is the max temperature relief setting for hot water tanks?

/.125 F - Answer-What is the max allowable water output temperature for hot water
system?

,/.True - Answer-All potable water system connections shall be positioned above the
normal bilge water accumulation level. T or F?

/.True - Answer-Exposed metallic parts of a potable water system shall have provisions
for electrical bonding. T or F?

/.Improper venting - Answer-For what reason might a holding tank collapse during
pump-out?

/.Type I - Answer-What type of MSD (Marine Sanitation Device) discharges effluent with
fecal coliform bacteria count <= 1,000 (per 100 ml) and no suspended solids?

/.Type II - Answer-What type of MSD (Marine Sanitation Device) discharges effluent
with fecal coliform bacteria count <= 200 (per 100 ml) and <= 150 mg suspended solids
per liter?

/.Type III - Answer-What type of MSD (Marine Sanitation Device) is designed to hold
sewage or any waste derived from sewage?

/.Retention System - Answer-What is the name given to the complete system including
toilets, hoses, pipes, holding tanks and fittings designed to receive, retain, vent and
pump out sewage?

/.Treatment System - Answer-What is the name of the system that includes all
sanitation equipment and fittings designed to receive, treat, vent and discharge
sewage?

/.Siphon break - Answer-What is another name for a vented loop that prevents back
siphoning by breaking suction yet allowing normal flow when pressurized?

/.True - Answer-True or False: If a portable toilet is secured and fitted with a deck pump-
out fitting and vent it qualifies as a type III device.

/.Prevention of siphoning - Answer-Why must careful consideration be given to the
location and routing of inlet and discharge lines for manual flush toilets when the "shut-
off" merely bleeds air into the inlet line?

/.Whenever components are installed below the max heeled water line - to prevent back
flow into the vessel or unintentional siphoning of untreated effluent overboard. - Answer-
When and why must siphon breaks be installed in a sewage system?

/.True - Answer-A seacock may be installed instead of a siphon break to prevent
discharge and back siphoning. T or F?

, /.The handle must be lockable in the direction of the holding tank - Answer-What special
provision must be included for a sewage y-valve when the discharge seacock is not
lockable?

/.Air Gap, Vacuum Break, Double Check Valve, Dedicated Water Tank - Answer-Name
four ways to separate a fresh water flushing system from potable water system.

/.1.5 inches - Answer-What is the minimum hose ID for use on un-macerated sewage?

/.linear or cross-linked polyethylene, 1/4 inch thick or greater. - Answer-What plastic
material is recommended for sewage holding tanks?

/.Epoxy and Vinyl Esther are ok, but polyester resin is not because of susceptibility to
osmotic blistering. - Answer-Of the three major type of Fiberglass Reinforced Plastic
(FRP), which one is not recommended and why?

/.5/8 inch - Answer-A removable holding tank's vent line shall be what minimum
diameter?

/.2X weight of tank and contents when full - Answer-What safety factor shall be utilized
when determining necessary restraining forces for installation of a holding tank?

/.neoprene, bonded to tank surface with non-hydroscopic adhesive. - Answer-What
material is recommended to be used to prevent chafe between metallic tanks and tank
supports, bracing, etc?

/.Similar coefficient of thermal expansion - helps prevent leaks. - Answer-Why is it
recommended to use plastic fittings with plastic holding tanks?

/.1.5 inch, internal national pipe thread (NPT) - liquid and vapor tight. - Answer-What
type of fitting shall be used for deck pump-out?

/.True - Answer-True or False: holding tank vent line shall have a constant rise from the
top of the tank to the vent fitting and be as short as possible.

/.True - Answer-Only anaerobic bacterial produce a smell. T or F?

/.24 inches - Answer-What is the minimal distance allowed between a holding tank vent
fitting and any opening into an accommodation space?

/.True. Maceration does not reduce bacteria content. - Answer-A macerator pump is not
a Type I, II, or III MSD.

/.False. - Answer-T or F: All macerator pumps are self-priming

/.Diaphragm Pump - Answer-What type of pump is used for flushing a toilet?

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller kartelodoc. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77254 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart