Oil Burner CAD Cell Operation, Heating, Manual D Test, Mechanical Law Exam, Mechanical A/C Service Exam, Heating, Michigan Mechanical Code 100% Correct $14.99   Add to cart

Exam (elaborations)

Oil Burner CAD Cell Operation, Heating, Manual D Test, Mechanical Law Exam, Mechanical A/C Service Exam, Heating, Michigan Mechanical Code 100% Correct

 4 views  0 purchase
  • Course
  • Oil Burner CAD Cell Operation, Heating, 2025-2026
  • Institution
  • Oil Burner CAD Cell Operation, Heating, 2025-2026

Oil Burner CAD Cell Operation, Heating, Manual D Test, Mechanical Law Exam, Mechanical A/C Service Exam, Heating, Michigan Mechanical Code 100% Correct...

Preview 4 out of 65  pages

  • November 4, 2024
  • 65
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Oil Burner CAD Cell Operation, Heating, 2025-2026
  • Oil Burner CAD Cell Operation, Heating, 2025-2026
avatar-seller
Easton
Oil Burner CAD Cell Operation, Heating, 2025-2026 Manual D Test, Mechanical
Law Exam, Mechanical A/C Service Exam, Heating, Michigan Mechanical
Code 100% Correct



Primary Control

Controls oil burner operation in that it will not give flame and signal if conditions around
it are bad.



CAD Cell

Watches for light to recognize the ignition for an oil burner, with resistances under 1600
ohms.



6 Ways to Show Appreciation for Your Child's Teacher

TT Terminals

Located on the rear side to connect to a signal that would ignite the oil burner when the
CAD cell criteria have been met.



Power Wires

White and black wires feed power supply into the primary control.



Electronic Transformer

Takes 120 volts from the primary control and sends 20,000 volts into the ignition.



Motor

Receives 120 volts from the primary control in order to pump and circulate air.



Solenoid

Stops fuel flow when power is removed and it cannot circulate oil without ignition.

,Resistance Value

Below 1600 ohms readings of CAD cell signal the primary control to turn on.



Multimeter

Device used to check resistance in CAD cell to ensure that it is working correctly.



Light Exposure

CAD cell resistance is affected by light exposure. The lower the reading the more light is
present.



Mega Ohms

CAD cell will read high resistance when exposed to light as part of normal operation.




Zero Ohms

Indicates faulty CAD cell. This reading should change depending on light exposure.



F Terminals

CFAD cell readings to identify if it is appropriate to turn the oil burner on.



Kiloohm

Unit of measure for electrical resistance, 1 kiloohm = 1000 ohms



Oil Primary Control

Device that monitors the CAD cell resistance detecting a flame

,Reset Button

Button used to reset an oil primary control system



Alligator Clip

Clip connected to multimeter for a resistance reading



Flame Resistance

Ideal CAD cell resistance range to detect a good flame, under 1600 ohms



Transformer

Device that changes voltage for the oil primary control system



120 Volts

Common voltage output for the oil primary control system



Frame Grounding

Ensures no electrical terminals come in contact with the system frame for safety



Electrodes

Pieces of the system that produce a spark for ignition in the oil burner system



70 degrees Fahrenheit is about the same

as how many degrees Celsius?

21



28 degrees Celsius is equilateral to ______ degrees Fahrenheit.

82

, On a low-pressure residential steam boiler, the relief device opens at?

15



If too much primary air is used the flame will __________?

lift off the burner



What operates the heat anticipator in a low voltage thermostat?

24 volts a/c



A limit control is located where in the electrical circuit?

either the 24 or 120- volt circuit



What is the usual oil pressure at the nozzle in a high pressure gun type oil burner?

100 psig




What license is required to perform a CSD-1 on An boiler that has an input rating of
1.7MBTU?

Mechanical Contractor Category 6



A psychrometer is a ________?

a hygrometer consisting of a wet-bulb and dry-bulb thermometer, the difference in the
two readings used to determine the atmospheric humidity.



A psychrometric chart is a ________?

chart where various property of air is plotted

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Easton. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75759 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.99
  • (0)
  Add to cart