Florida Home Inspector Exam Questions And Answers 100% Pass Service entrace conductors run from the service drop to the service box or service panel. True or False? - answerTrue The service size is determined by the amperage and the voltage ratings of the service. - answerTrue Is the service ...

[Show more]

Preview 4 out of 105  pages

  • October 28, 2024
  • 105
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Home inspector
  • Home inspector
avatar-seller
Brightstars
©BRIGHTSTARS EXAM SOLUTIONS
10/21/2024 9:24 PM



Florida Home Inspector Exam Questions
And Answers 100% Pass



Service entrace conductors run from the service drop to the service box or service panel. True or
False? - answer✔True
The service size is determined by the amperage and the voltage ratings of the service. -
answer✔True

Is the service drop overhead or underground? - answer✔Overhead

Are service laterals overhead or underground? - answer✔Underground

The drip loop is typically part of the service drop. True or False? - answer✔False
The wire size for the service drop must be the same as the wire size for the service entrance
conductors. True or False? - answer✔False

How many wires would you typically find in a 240-volt service drop? - answer✔3

What would 4 wires mean? - answer✔3-phase electricity

What would 2 wires usually mean? - answer✔120 volt service

List 7 common problems with service drops. - answer✔1. Overhead wires too low.
2. Damaged or frayed wires.
3. Trees or vines interfering with wires.
4. Wires too close to doors or windows.
5. Wires not well-secured to the house.
6. Poor connection between service drop and service entrance.

, ©BRIGHTSTARS EXAM SOLUTIONS
10/21/2024 9:24 PM

7. Inadequate clearance from roofs.

List clearances above ground, swimming pools, and roofs. - answer✔above roadway--18 ft.
above driveway--12 ft.
above flat roof--8 to 10 ft.
above sloped roof--18 inches
away from water in swimming pool--22.5 ft
3 ft. above sloped roof with pitch > 4 in 12
above walkway--10 ft.

The service entrance conductors run from the _________ to the ___________. - answer✔service
drop to service box

All service entrance conductors must be in conduit. True or False? - answer✔False
All service entrance conductors must be attached above roof level. True or False? -
answer✔False

The drip loop should be as close to the roof as possible. True or False? - answer✔False

List 10 common problems with service entrance conductors. - answer✔1. No drip loop
2. No mast head
3. Mast head not weather tight.
4. Mast or conduit bent.
5. Mast or conduit rusted.
6. Mast rotted (if wood).
7. Mast conduit or cable not well secured.
8. Mast conduit or cable not weather tight.
9. Conduit or cable not well sealed at house/wall penetration.
10. Cable frayed, damaged, or covered by siding.

List 4 common areas of water penetration into service entrances. - answer✔1. conduit joints
2. mast head

, ©BRIGHTSTARS EXAM SOLUTIONS
10/21/2024 9:24 PM

3. roof flashing
4. meter base
5. house entry

List 2 functions of the drip loop. - answer✔1. Prevents water entry into the conduit or service
entrance conductors.
2. Shows that the service drop wires are not straining the splices.

Roughly 999 out of 1000 houses have _________ volts available. - answer✔240

Roughly 999 out of 1000 houses have __________ service entrance wires. - answer✔3

Load calculations are part of a home inspection. - answer✔False
Implications of an undersized service include:
a. shock hazard
b. fire hazard
c. shock and fire hazard
d. melting insulation

e. nuisance tripping of the main fuses and breakers - answer✔e.

What is the largest single-phase service that you are likely to find in a home? - answer✔400
amps
What size copper wire would you expect to find on the service entrance for:
a. 60-amp service
b. 100-amp service

c. 200-amp service - answer✔a. 6 gauge
b. 4 gauge
c. 2-0 gauge
Which of the following is a reliable way to identify the service size?
a. the size of the service drop wires
b. the distribution panel rating

, ©BRIGHTSTARS EXAM SOLUTIONS
10/21/2024 9:24 PM

c. the service box rating
d. the service entrance conductor

e. the service entrance conduit size - answer✔d.

Aluminum is an acceptable service entrance conductor material. True or False? - answer✔True
A fused 200-amp service has two 100-amp fuses in the service box. True or False? -
answer✔False
If you can't read the size of the fuses in the service box, you should remove them to try to get a
better look. True or False? - answer✔False
Which of the following is a safety issue:
a. The main fuses have a lower rating than the service entrance wire.
b. The main fuses have a higher rating than the service entrance wire.
c. The service box has a higher rating than the service entrance wires.
d. The service box has the same rating as the service entrance wires.

e. The distribution panel has a larger rating than the service entrance wires. - answer✔b

The service box can be inside, outside, or in the garage. True or False? - answer✔True
There can be up to 10 throws to disconnect all the electricity in the house. True or False? -
answer✔False
The service box may stand alone or may be combined with the distribution panel. True or False?
- answer✔True

List common conditions you might find in a service box. - answer✔1. poor access or location
2. loose
3. rust or water in box
4. unprotected opening
5. damaged parts
6. overheating
7. incorrect fuse or breaker size; box rating too small

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Brightstars. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.49
  • (0)
  Add to cart