Many electricians wire the lights and receptacles in a room on different
circuits because this -ANSWER-offers the advantage that all power in
a room will not go out if the overcurrent protective device trips
Ceiling fan speed can be controlled by -ANSWER-pull chain on the
fan; speed control mounted in a wall box; remote control similar to
TV/VCR type
The NEC allows what maximum number of receptacle outlets to be
connected on a 120-volt residential lighting or small-appliance branch
circuit? -ANSWER-unlimited
The maximum volt-ampere loading permitted on a 20-ampere branch
circuit with a continuous load is -ANSWER-1920 VA
Which of the following switch types is rarely used in residential wiring?
-ANSWER-double-pole
When someone decides to use a bedroom as a home office instead, -
ANSWER-a lot of electronic equipment will have to be plugged in
When installing a ceiling paddle fan, the outlet box must be -
ANSWER-listed and marked as acceptable for fan support
,Receptacles installed on 15- and 20-ampere branch circuits must be
of the ______ type. -ANSWER-grounding
The selection of outlet boxes and switch boxes is made by the
electrician. These decisions are based on Code requirements, space
allowances, good wiring practices, and -ANSWER-common sense
Ceiling fan boxes designed to support more than _____ pounds must
have the maximum weight they are designed to support included in
the marking. -ANSWER-35
In a home office, the current draw is -ANSWER-low
A raised plaster cover (often called a plaster ring or mud ring) is
permitted to increase the maximum number of conductors permitted in
an outlet box when it is -ANSWER-marked with its cubic-inch volume
A light above a workbench is an example of -ANSWER-task lighting
A light dimmer ______ be used as a speed control for a ceiling fan or
other motor. -ANSWER-should not
Receptacle outlets must be installed in any wall space ______ or
more in width. -ANSWER-24in (600mm)
In a room that may be used as a home office, you could consider -
ANSWER-using 12 AWG for the home run or even the entire branch
circuit(s); wiring in quadplex receptacles instead of duplex
receptacles; using only plug-in strips that are UL listed
During the winter, it is suggested that a paddle fan should -ANSWER-
draw up air
,Sliding glass panels ______ considered to be wall space, the same as
any other interior or exterior door. -ANSWER-are not
Which of the following is required in order to dim fluorescent fixtures? -
ANSWER-fluorescent dimmer; dimming ballasts
Ceiling fans must be specially supported for all of the following
reasons, except for -ANSWER-safe grounding
Residential wiring plans generally show lighting and receptacles outlet
locations but not circuits. The electrician should design the installation
with which of the following in mind? -ANSWER-economy-minimizing
the number and length of circuits; convenience for the homeowner or
other user; NEC requirements
When designing a home office, you could consider roughing in more
wall receptacles than the NEC -ANSWER-minimum
Install luminaires listed for _____ locations if they will be subject to
shower spray. -ANSWER-wet
As defined in Article 100, a bathroom is required to have a -ANSWER-
basin
GFCI-protected receptacles _____ permitted to be installed within a
tub or shower space. -ANSWER-are not
Recessed or surfaced-mounted luminaires and recessed exhaust fans
may be located within the restricted zone near the bathtub -ANSWER-
may
, Ceiling-suspended paddle fans must not be located within a zone
measured _____ horizontally and ____ vertically from the top of the
bathtub rim or top of a shower stall threshold. -ANSWER-3ft (900mm);
8ft (2.5m)
Lighting fixtures intended for installation in wet locations must be -
ANSWER-marked "suitable for wet locations"
A location exposed to the weather is a _____ location -ANSWER-wet
The Code permits all bathroom receptacles to be on a single _____
branch circuit so long as it doesn't supply other loads -ANSWER-20-
ampere
In addition to being fastened to the outlet box, the track for track
lighting is generally fastened to the ceiling with _____. -ANSWER-
toggle bolts and screws
Lighting track in residential installations shall not be cut to length in the
field unless permitted by the ______ -ANSWER-manufacturer
When using nonmetallic boxes, the volume allowance is based on
______ -ANSWER-wiring devices; cable clamps; equipment
grounding conductors
Lighting track is not permitted to be installed less than _____ above a
finished floor unless it is protected against physical damage, or if the
track is of the low-voltage type operating at less than 30 volts rms
open-circuit voltage. -ANSWER-5 ft
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Tutorhailey. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $19.49. You're not tied to anything after your purchase.