When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? → 18 months When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? → 66 inches Elevator lobb...

[Show more]

Preview 3 out of 16  pages

  • October 20, 2024
  • 16
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • NICET
  • NICET
avatar-seller
TestTrackers
2 0 2 4 /2025 | © copyright | This work may not be copied for profit gain Excel!


NICET Fire Alarm Level 1 Questions and
Correct Answers the Latest Update and
Recommended Version
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum

interval for testing?

→ 18 months


When installing a wall-mounted fire telephone appliance to the public, what is the acceptable

maximum mounting height from the floor?

→ 66 inches


Elevator lobby smoke detectors shall be mounted within a maximum of which distance from the

center-line of the door?

→ 21 feet


At minimum, when working near power lines with voltage of 600 volts and lower, an aerial lift

operator shall maintain which distance from the lines?

→ 10 feet


The use of unprotected EMT shall be permitted under which conditions?


→ when in direct contact with the earth


According to NFPA 70, what is the maximum unsupported length of 1/2-inch flexible metallic

conduit where flexibility is required after installation?




1|Page| GradeA+ | 2 0 0 2 5

,2 0 2 4 /2025 | © copyright | This work may not be copied for profit gain Excel!

→ 4 1/2 feet


What is the maximum bend (in degrees) permitted in a conduit run between outlet boxes?


→ 360 Degrees


If the primary power is disconnected and the fire alarm system goes into an alarm condition,

what is the minimum acceptable time for secondary power to operate the voice evacuation

systems?

→ 15 minutes


A riser room temperature switch should activate when the temperature falls below which level?


→ 40 degrees F


According to NFPA 72, what is the maximum sound pressure level permitted in a space with

notification appliances?

→ 110 dBA


What is the minimum interval for testing a single-station smoke detector in multifamily units?


→ Annually


Where should a technician install a detector in relation to beam that is less than 12 inches

deep and less that 8 feet in center?

→ At the bottom of the beam


An existing fire alarm cable in a drop ceiling will be spliced. which one of the following splice

locations will comply with NFPA 70?

1|Page| GradeA+ | 2 0 0 2 5

, 2 0 2 4 /2025 | © copyright | This work may not be copied for profit gain Excel!

→ secured inside a listed box or enclosure


Which function shall be tested for each newly installed smoke detector?


→ smoke entry?


An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling, interrupted by 4-inch

beams spaced every 10 feet. How many heat detectors with a listed 30 foot spacing are

required?

→ 6 heat detectors


At which height must cables be physically protected when being installed within an exposed

ceiling?

→ 7 feet


When shall smoke detectors be installed during the construction process?

→ After the final cleanup of all trades


Where structural members are provided, intermediate metal conduit shall be secured within

which maximum distance from an outlet box"

→ 3 feet


The requirement forbidding fire alarm circuits from being T-tapped, unless indicated by the

manufacturer's instructions, is intended to prevent which type of improper malfunction?

→ monitoring integrity of installation conductors?


What is the maximum operating temperature of TW insulation?

1|Page| GradeA+ | 2 0 0 2 5

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TestTrackers. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76799 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart