100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
FDNY Z51 EXAM QUESTIONS AND ANSWERS $12.49   Add to cart

Exam (elaborations)

FDNY Z51 EXAM QUESTIONS AND ANSWERS

 6 views  0 purchase
  • Course
  • FDNY Z51
  • Institution
  • FDNY Z51

FDNY Z51 EXAM QUESTIONS AND ANSWERS

Preview 2 out of 13  pages

  • October 20, 2024
  • 13
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • FDNY Z51
  • FDNY Z51
avatar-seller
GEEKA
FDNY Z51 EXAM QUESTIONS AND ANSWERS
Engineer's Minimum Reading Log Requirement - Answers-An engineer needs to log
readings once per shift.

Engineer's Minimum Reading Log Requirement - Answers-An engineer needs to log
readings once per shift.

Phase 2 Firemen Service - Answers-The elevator operator is the only person that can
control the elevator.

Phase 2 Firemen Service - Answers-The elevator operator is the only person that can
control the elevator.

Engineer's Responsibility with Running Machine - Answers-If the machine is running,
the engineer should not leave the building.

Engineer's Responsibility with Running Machine - Answers-If the machine is running,
the engineer should not leave the building.

Gauge Reading for Chilled Water System - Answers-A gauge reading of saturation
pressure of refrigerant with chilled water as the cooling medium estimates the
temperature of the chilled water being pumped to the spaces being cooled.

Gauge Reading for Chilled Water System - Answers-A gauge reading of saturation
pressure of refrigerant with chilled water as the cooling medium estimates the
temperature of the chilled water being pumped to the spaces being cooled.

Refrigerant Escape Awareness - Answers-In the event of a refrigerant escape, the
engineer should be aware of asphyxiation.

Refrigerant Escape Awareness - Answers-In the event of a refrigerant escape, the
engineer should be aware of asphyxiation.

Chemical Fire Extinguisher and System Requirement - Answers-A chemical fire
extinguisher and system are needed where water is not sufficient.

Chemical Fire Extinguisher and System Requirement - Answers-A chemical fire
extinguisher and system are needed where water is not sufficient.

Refrigerants Inside Machine Gauges - Answers-The refrigerants found inside the
machine gauges are the same type as the refrigerant inside the machine.

Refrigerants Inside Machine Gauges - Answers-The refrigerants found inside the
machine gauges are the same type as the refrigerant inside the machine.

, Fireproof Decorations Purpose - Answers-Fireproof decorations in buildings are used so
they don't catch fire in an emergency.

Fireproof Decorations Purpose - Answers-Fireproof decorations in buildings are used so
they don't catch fire in an emergency.

Water Regulating Valves Usage - Answers-Water regulating valves are used to maintain
condenser pressure to a predetermined level.

Water Regulating Valves Usage - Answers-Water regulating valves are used to maintain
condenser pressure to a predetermined level.

Emergency Power Testing Frequency - Answers-Emergency power testing must be
done monthly.

Emergency Power Testing Frequency - Answers-Emergency power testing must be
done monthly.

AB29 Certificate of Fitness Holder's Responsibility - Answers-The holder should inspect
the battery system.

AB29 Certificate of Fitness Holder's Responsibility - Answers-The holder should inspect
the battery system.

Steam Turbine Warm-up Time - Answers-It takes 10 to 15 minutes to warm up a steam
turbine.

Steam Turbine Warm-up Time - Answers-It takes 10 to 15 minutes to warm up a steam
turbine.

Pressure Relief Out vs. Fusible Plugs - Answers-A pressure relief out is better than
fusible plugs to minimize refrigerant loss.

Pressure Relief Out vs. Fusible Plugs - Answers-A pressure relief out is better than
fusible plugs to minimize refrigerant loss.

Hot Work Near Sprinkler Head - Answers-To prevent the fire alarm system from going
off, put a non-combustible barrier to protect the sprinkler.

Hot Work Near Sprinkler Head - Answers-To prevent the fire alarm system from going
off, put a non-combustible barrier to protect the sprinkler.

Inspection of Sprinkler Heads - Answers-Automatic sprinkler heads need inspecting.

Inspection of Sprinkler Heads - Answers-Automatic sprinkler heads need inspecting.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

78252 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart