NFPA 25 correct answers Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
AFFF stands for? correct answers Aqueous Film Forming Foam
What percentage net weight loss on a halon 1301 system requires refill/replacement ? correct answers 5% Net WEIGHT
...
TFM-04 FEL-A || with 100% Accurate Solutions.
NFPA 25 correct answers Standard for the Inspection, Testing, and Maintenance of Water-Based
Fire Protection Systems
AFFF stands for? correct answers Aqueous Film Forming Foam
What percentage net weight loss on a halon 1301 system requires refill/replacement ? correct
answers 5% Net WEIGHT
What percentage pressure loss on a halon 1301 system requires replacement/refill ? correct
answers 10% PRESSURE
What percentage loss on c02 system requires replacement ? correct answers 10%
NFPA 12 correct answers Standard on Carbon Dioxide Extinguishing Systems
NFPA 12a correct answers Standard on Halon 1301 Fire Extinguishing Systems
NFPA 2001 correct answers Standard on Clean Agent Fire Extinguishing Systems
NFPA 11 correct answers Standard for Low-, Medium-, and High-Expansion Foam
NFPA 15 correct answers Standard for Water Spray Fixed Systems for Fire Protection
NFPA 16 correct answers Standard for the Installation of Foam-Water Sprinkler and Foam-
Water Spray Systems
NFPA 18 correct answers Standard on Wetting Agents
How often shall you weigh halon 1301 cylinders? correct answers Semi-annually shall weigh
cylinder and note weight/pressure on tag attached to container
How often shall you inspect halon 1301 enclosure ? correct answers Semi-annually
How often shall you inspect enclosure of all other systems besides for halon 1031? correct
answers Annually
How often shall you inspect halon 1301 systems ? correct answers Semi-annually
How often shall you inspect C02 operational condition? correct answers Every 30 days C02
operational condition shall be checked (usually by building representative/maintenance man)
How often are ALL systems hoses to be tested? correct answers Every 5 years ALL systems
hoses require test
, Low pressure system hoses shall be tested at what PSI? correct answers 900 PSI
High pressure system hoses shall be tested at what PSI? correct answers 2,500 PSI
NFPA 25 how often to test or replace gauges? correct answers Every 5 years gauges shall be
tested or replaced. If tested gauges must test within 3% of a calibrated gauge
File a report with recommendation with the? correct answers Owner
Can you perform a visual inspection on a halon 1301 system in lieu of a hydrostatic test? correct
answers Yes, every 5 years a thorough external visual inspection shall be given in lieu of a hydro
as long as the system has remained in service. Also do not stamp pressurized cylinder
Is it acceptable to discharge halon 1301 into atmosphere ? correct answers NO! Never discharge
halon 1301
3%AFFF means? correct answers 3% foam 97% water
FFFP correct answers Film Forming Fluoroprotein Foam
Different basic types of foam system? correct answers 1.fixed
2.semi-fixed
3.portable
4.mobile
Can you use C02 for cellulose/hydride metals? correct answers No you can not use C02 on
hazards that contain oxygen
Can flush bushings be used? correct answers No. Flush bushings shall not be used
Low pressure supply pipe shall be a minimum of ? correct answers Schedule 40
C02 container being stored at ambient room temperature would be a ? correct answers High
pressure systems are stored at ambient room temperature
C02 container being stored at 0°F/300PSI would be a ? correct answers Low pressure systems
are stored in a temperature controlled environment of 0°F
DOT/CTC containers shall not be refilled unless they have been tested within 5 years? correct
answers That is correct. DOT containers have to by hydro tested if it has been 5 years since the
last test
Pressure test on ALL system hoses shall be correct answers Filled with water for 1 minute and
pressurized to ensure no leaks. After test shall dry hose at a temperature of no higher than 150°F.
If hose passes shall be marked and returned to service
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller FullyFocus. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.79. You're not tied to anything after your purchase.