What is the fire rated temp for fire alarm? - ANSWER 150 c
What is the NEC chapter that covers fire protecting? - ANSWER CH 3 NEC
What type of smoke detector is best for ...
FSDNY S98 (2024/2025) EXAM QUESTIONS
WITH VERIFIED CORRECT ANSWERS || 100%
GUARANTEED PASS!!
<BRAND NEW VERSION>
What is the fire rated temp for fire alarm? - ANSWER ✔ 150 c
What is the NEC chapter that covers fire protecting? - ANSWER ✔ CH 3 NEC
What type of smoke detector is best for sinclering fires? - ANSWER ✔ Ionization
How many supervisory device can you have on one crt? - ANSWER ✔ 20
What is the max sound level in Private mode? - ANSWER ✔ 55 dba
What is the min sound level in Private mode? - ANSWER ✔ 45 dba
How long should a panel charge batteries after being drained? - ANSWER ✔ 48
hours
What is the max sound level in sleeping area? - ANSWER ✔ 90 dba
How often should nickelcod batteries be inspected? - ANSWER ✔ Annually
How long should central station alarm offline records be kept? - ANSWER ✔ 1
year.
What should you do if a smoke detector is out of range? - ANSWER ✔ Should be
cleaned, recalibrated or replaced
,Backup power for voice emergency? - ANSWER ✔ 24,15
Classifications of green heat detectors? - ANSWER ✔ Very extra high
The phone lines shall be connected upstream of any telephone system used in -
ANSWER ✔ building
How far should the control relay be from the control unit its shutting down? -
ANSWER ✔ 37 feet
The total sound level shall not exceed 110 db anywhere in the occupied area. -
ANSWER ✔
A row of detectors shall first be spaced and at or withing___feet of the peak of the
ceiling measured horizontally - ANSWER ✔ 37
High rise building are class - ANSWER ✔ A
Visible appliances shall have a min flash rate of _____flash per sec and a max
flash of __flashes per sec - ANSWER ✔ 1,2
Emergency lighting shall be capable of operating for hours at the prop.. station -
ANSWER ✔ 26
When silenced the trouble signal shall automatically resound at least once
every__hours. - ANSWER ✔ 24
How do you test a line type restorable heat detector? - ANSWER ✔ Heat test shall
be performed.
A device that malfunctions and goes into alarm due to ......... maintenance is what?
- ANSWER ✔ Nonsense alarm
Strobe should be how many feet from the end of the corridor? - ANSWER ✔ 15
feet
A space has 2 levels each level is 4000 sqft and and additional level with 3000 sqft.
How many smoke detectors are needed for the space? - ANSWER ✔ 12
, How many wires can you fit withing ¾ box - ANSWER ✔ 22
They show you a temper switch with exposed wiring and the 1900 box was not
painted red and they ask you if this is correct or not? - ANSWER ✔ No
The Dact has (7) lines should be the same transmission or separate? - ANSWER
✔ Pg 75 NFPA 8.6.3.2.1.5
What type of battery is commonly used on fire alarm systems? - ANSWER ✔
Codes to be familiar with - ANSWER ✔ NFPA 72 (2010), 2014 NYC fire code
(FC), Building code, Rules of the city of new york (FR), NYC Electrical code
Alarm signal - ANSWER ✔ A signal indicating an emergency requiring
immediate action, such as a signal indicative of fire.
Automatic - ANSWER ✔ Any device that initiates system function without need
for human intervention
Defined Fire Alarm System - ANSWER ✔ A fire alarm system or any sub-system
thereof that automatically transmits signals to the department or a central station
and that is installed in premises which are required to have a fire alarm system.
Designated Representative - ANSWER ✔ A person or entity designated by the
subscriber who shall be responsible for receiving notifications from the central
station company concerning the status of the protective signaling system at the
protected premises and who is authorized to take action with respect to such
system.
Emergency alarm system - ANSWER ✔ A system that provides indication and
warning of emergency situations involving hazardous
materials and summons appropriate aid. A signal may be audible, visual, or voice
instruction.
Fire Alarm Control Unit - ANSWER ✔ System component that receives input
from automatic and manual fire alarm devices and may provide power to detection
devices or communication devices.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller ProfBenjamin. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $9.49. You're not tied to anything after your purchase.