Arizona Contractor License CR-67 Prep Exam And Correct Answers.
5 views 0 purchase
Course
HVAC CONTRACTOR
Institution
HVAC CONTRACTOR
Alternating Current (AC) always flows one way then the other? - Answer True. AC always flows one way then the other.
The frequency of AC is measured in? - Answer Measured in hertz Hz
What refers to a voltage can convey information? - Answer Electrical Signal
What refers to the max...
Arizona Contractor License CR-67 Prep
Exam And Correct Answers.
Alternating Current (AC) always flows one way then the other? - Answer True. AC always flows one way
then the other.
The frequency of AC is measured in? - Answer Measured in hertz Hz
What refers to a voltage can convey information? - Answer Electrical Signal
What refers to the maximum voltage that can be reached by a signal? - Answer Amplitude
Electricity may flow only when? - Answer There has to be a for it to return making a complete circuit
What is the return path for electrical power to flow back to the service panel? - Answer Neutral
The live wire is always ungrounded? - Answer True. They are very hot caring electrical power
A ground electrode conductor originates at the neutral or equipment ground bus of the service panel? -
Answer True
A ground electrode should not be made in contact with the earth? - Answer False. sound be on contact
with the earth
Compare Watts with Voltage - Answer Watts are the measure of power. Voltage is the measure of
potential energy.
You should size conductors no less ______ of the continuous loads plus _________ of the non-
continuous loads,. - Answer 125% / 100%
,Conductor sizes are often expressed in? - Answer American Wire Gage (AWG)
What refers to the allowable current-carrying capacity of a conductor? - Answer Ampacity
The insulation type determines the areas the writers can and cannot used? - Answer True
RHH wires use rubber insulation that is high heat resistant and is good in? - Answer Is only good in dry
locations.
RHW-2 wires use the rubber insulation but are suitable for wet locations? - Answer True
What cables can be used inside wall, ceiling or under the floor. - Answer Non-metallic (NM)
What cables are most appropriate for damp areas? - Answer Underground feeder (UF) or Non-metallic
Wet underground (NMWU)
An insulated grounded conductor which is ____ AWG or below should be identified by a continuous
white or gray outer finish. - Answer 6 AWG
What is the amount of voltage measured between any two line conductors of a balanced three-phase
system. - Answer Line voltage
What describes the voltage measured across any one component of a balanced three-phase system. -
Answer Phase Voltage
A _______ is unintentional mess up. - Answer Ground Fault
, An effective Ground-Fault current path is? - Answer An effective Ground-Fault current paths a path
intentionally constructed to facilitate the operation of the overcurrent protective devices currently in
place.
GFCI is never sensitive to small "leaks" of current - Answer False. GFCI = ground-fault circuit interrupter
Grounding and bonding means exactly the same thing? - Answer False. Bonding is a means of allowing
electrical continuity between metallic objects.
A typical work space (for a working voltage under 600V) should have a minimum headroom of ______ m.
- Answer 2.0 m
typically there are ____ hot wires running from the utility company into the service panel. - Answer 2
A service disconnect need to have a rating which is? - Answer No less than that the calculated load or
for the type of installation
Fast- blow fuses tend to open real quick when the rated current is reached. - Answer True
System grounding is required when you have a supply transformer of a SOV or lower system? - Answer
System grounding is required when you have a supply transformer of a 50V or lower system which itself
is supplied from a source over 150V to the ground
On a class 1 circuit it is ok to use smaller wire sizes than normal power circuits such as. - Answer
Anything 16 AWG or lower
Class 1 signaling and remote control circuits are limited too? - Answer 600 Volts
When a circuit controls equipment can introduce a direct life safety hazard, the circuit has to be? -
Answer Class 1
Class 2 circuit must be kept separate from lighting? - Answer True
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller COCOSOLUTIONS. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.09. You're not tied to anything after your purchase.