Floating strainers can draft water from sources as shallow as:
Select one:
a. 12 inches (300 mm).
b. 48 inches (1 200 mm).
c. 24 inches (600 mm).
d. 36 inches (900 mm). - answerc. 24 inches (600 mm)
Isolation and control valves are usually constructed of:
Select one:
a. PVC.
b. aluminum.
c. brass.
d. plastic. - answerc. brass.
Standard three-way fire hydrants require a ___-inch (mm) valve opening.
Select one:
a. 4 (100)
b. 3 (75)
c. 5 (125)
d. 6 (150) - answerc. 5 (125)
Which of the following is a hydrant that receives water from only one direction?
Select one:
a. Dead-end hydrant
b. Unidirectional hydrant
c. Circulating hydrant
d. Limited hydrant - answera. Dead-end hydrant
Dry-barrel hydrants are designed to have water inside them at all times.
Select one:
True
False - answerF
Fire hydrant locations are generally determined by the fire department.
Select one:
True
False - answerF
Two or more primary feeders should run from the source of the water supply to high-risk
and industrial districts along separate routes.
, Select one:
True
False - answerT
A drafting operation will require a minimum of ___ inches (mm) of water above and
below the hard intake strainer.
Select one:
a. 6 (150)
b. 12 (300)
c. 24 (600)
d. 36 (900) - answerc. 24 (600)
All hydrants must be opened and closed ___ to prevent damage.
Select one:
a. partially
b. at least twice
c. slowly
d. quickly - answerc. slowly
Drafting hydrants are designed to supply at least:
Select one:
a. 250 gpm (1 000 L/min).
b. 500 gpm (2 000 L/min).
c. 750 gpm (3 000 L/min).
d. 1,000 gpm (4 000 L/min). - answerd. 1,000 gpm (4 000 L/min).
During relay pumping, which apparatus should be located at the water source?
Select one:
a. Apparatus with the largest tank
b. Apparatus with the most amount of supply hose
c. Apparatus with the greatest pumping capacity
d. Apparatus with the fastest dumping capabilities - answerc. Apparatus with the
greatest pumping capacity
Fire hydrant markings can be used to designate:
Select one:
a. distance from nearest fire department.
b. distance from the next hydrant.
c. typical water pressure.
d. flow capacity. - answerd. flow capacity.
Fire hydrant tops and discharge caps should be painted as required in:
Select one:
a. NFPA® 71.
b. NFPA® 291.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller jw638729. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $14.49. You're not tied to anything after your purchase.