100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Mastering Ultrasound Physics: Comprehensive Practice Questions for the SPI Exam" Subtitle: "In-Depth Review of Key Topics from Sidney K. Edelman’s 'Understanding Ultrasound Physics' with Varying Difficulty Levels and Detailed Explanations $35.99   Add to cart

Exam (elaborations)

Mastering Ultrasound Physics: Comprehensive Practice Questions for the SPI Exam" Subtitle: "In-Depth Review of Key Topics from Sidney K. Edelman’s 'Understanding Ultrasound Physics' with Varying Difficulty Levels and Detailed Explanations

 9 views  0 purchase
  • Course
  • PT - Physical Therapist
  • Institution
  • PT - Physical Therapist

"Mastering Ultrasound Physics: Comprehensive Practice Questions for the SPI Exam" is an all-inclusive study tool designed to thoroughly prepare you for the SPI physics exam. This guide is based on Sidney K. Edelman’s highly regarded textbook, Understanding Ultrasound Physics, and covers all key c...

[Show more]

Preview 4 out of 101  pages

  • September 22, 2024
  • 101
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
book image

Book Title:

Author(s):

  • Edition:
  • ISBN:
  • Edition:
  • PT - Physical Therapist
  • PT - Physical Therapist
avatar-seller
Estonloyford
Practice Questions
Ultrasound Wave Properties
1. Multiple Choice: What is the typical range of frequencies used in diagnostic ultrasound?
o A) 1-3 MHz
o B) 2-15 MHz
o C) 20-50 MHz
o D) 50-100 MHz
o Correct Answer: B) 2-15 MHz
o Explanation: Diagnostic ultrasound typically uses frequencies in the range of 2-15 MHz to
balance resolution and penetration depth.
2. True/False: The speed of sound in soft tissue is approximately 1540 m/s.
o Answer: True
o Explanation: The average speed of sound in soft tissue is about 1540 m/s, which is a standard
assumption in ultrasound imaging.
3. Short Answer: Define acoustic impedance and explain its significance in ultrasound imaging.
o Answer: Acoustic impedance is the product of the density of a medium and the speed of sound
within that medium. It is significant because differences in acoustic impedance at tissue
boundaries cause reflections, which are detected to form ultrasound images.

Imaging Principles
4. Multiple Choice: What is the primary purpose of using a gel during an ultrasound examination?
o A) To cool the transducer
o B) To reduce friction
o C) To eliminate air between the transducer and skin
o D) To enhance image contrast
o Correct Answer: C) To eliminate air between the transducer and skin
o Explanation: The gel eliminates air, which is a poor conductor of ultrasound waves, ensuring
better transmission of sound into the body.
5. True/False: Higher frequency transducers provide better penetration but lower resolution.
o Answer: False
o Explanation: Higher frequency transducers provide better resolution but have lower penetration
depth.
6. Short Answer: Explain the concept of axial resolution in ultrasound imaging.
o Answer: Axial resolution refers to the ability to distinguish two structures that are close to each
other along the axis of the ultrasound beam. It is determined by the spatial pulse length and is
improved with higher frequency transducers.

Doppler Effect
7. Multiple Choice: What does the Doppler shift in ultrasound measure?
o A) Tissue density
o B) Blood flow velocity
o C) Acoustic impedance
o D) Transducer frequency
o Correct Answer: B) Blood flow velocity

,o Explanation: The Doppler shift measures changes in frequency due to the motion of blood cells,
allowing the calculation of blood flow velocity.
8. True/False: Continuous wave Doppler can measure high velocities without aliasing.
o Answer: True
o Explanation: Continuous wave Doppler can measure high velocities without aliasing because it
continuously transmits and receives ultrasound waves.
9. Short Answer: Describe the principle of color Doppler imaging.
o Answer: Color Doppler imaging uses the Doppler effect to visualize blood flow within vessels.
It assigns different colors to different flow directions and velocities, providing a visual
representation of blood flow patterns.

Artifacts
10. Multiple Choice: Which artifact is characterized by multiple equally spaced echoes?
o A) Shadowing
o B) Enhancement
o C) Reverberation
o D) Mirror image
o Correct Answer: C) Reverberation
o Explanation: Reverberation artifact occurs due to multiple reflections between two strong
reflectors, creating equally spaced echoes.
11. True/False: Acoustic shadowing occurs when sound waves pass through a highly attenuating
structure.
o Answer: True
o Explanation: Acoustic shadowing occurs when sound waves are blocked or significantly
attenuated by a structure, creating a shadow behind it.
12. Short Answer: Explain the cause of the mirror image artifact in ultrasound.
o Answer: The mirror image artifact occurs when sound waves reflect off a strong reflector and
then encounter another structure, creating a duplicate image of the structure on the opposite side
of the reflector.

Safety Standards
13. Multiple Choice: What is the primary concern regarding the safety of diagnostic ultrasound?
o A) Radiation exposure
o B) Thermal effects
o C) Magnetic field exposure
o D) Electrical shock
o Correct Answer: B) Thermal effects
o Explanation: The primary safety concern with diagnostic ultrasound is the potential for thermal
effects, where the absorption of ultrasound energy can lead to a rise in tissue temperature.
14. True/False: The mechanical index (MI) is used to assess the potential for thermal bioeffects in
ultrasound imaging.
o Answer: False
o Explanation: The mechanical index (MI) is used to assess the potential for mechanical
bioeffects, such as cavitation, not thermal effects.
15. Short Answer: What does the ALARA principle stand for, and why is it important in ultrasound
imaging?

,o Answer: ALARA stands for “As Low As Reasonably Achievable.” It is important in ultrasound
imaging to minimize patient exposure to ultrasound energy while obtaining the necessary
diagnostic information.

Mixed Questions
16. Multiple Choice: Which of the following factors can increase the risk of cavitation in ultrasound
imaging?
o A) High-frequency transducers
o B) Low-frequency transducers
o C) Short exposure time
o D) Low power output
o Correct Answer: B) Low-frequency transducers
o Explanation: Low-frequency transducers can increase the risk of cavitation due to the larger
pressure variations they produce.
17. True/False: The thermal index (TI) is used to assess the potential for mechanical bioeffects in
ultrasound imaging.
o Answer: False
o Explanation: The thermal index (TI) is used to assess the potential for thermal bioeffects, not
mechanical effects.
18. Short Answer: Describe the principle of pulse-echo imaging in ultrasound.
o Answer: Pulse-echo imaging involves sending short pulses of ultrasound into the body and
receiving the echoes that are reflected back from tissue interfaces. These echoes are used to
create an image of the internal structures.
19. Multiple Choice: What is the primary use of M-mode ultrasound?
o A) Measuring blood flow velocity
o B) Visualizing internal structures
o C) Assessing motion of structures
o D) Storing patient data
o Correct Answer: C) Assessing motion of structures
o Explanation: M-mode ultrasound is used to assess the motion of structures, such as heart valves,
by displaying the movement over time.
20. True/False: Higher frequency transducers provide better resolution but have lower penetration
depth.
o Answer: True
o Explanation: Higher frequency transducers provide better resolution but have lower penetration
depth due to increased attenuation of the sound waves.

Practice Questions
Ultrasound Wave Properties
1. Multiple Choice: Which property of ultrasound waves determines their ability to penetrate
tissues?
o A) Frequency
o B) Amplitude
o C) Wavelength
o D) Velocity
o Correct Answer: A) Frequency

, o Explanation: Lower frequency ultrasound waves penetrate tissues more effectively than higher
frequency waves, which are absorbed more quickly.
2. True/False: The wavelength of an ultrasound wave is inversely proportional to its frequency.
o Answer: True
o Explanation: Wavelength and frequency are inversely related; as frequency increases,
wavelength decreases.
3. Short Answer: What is the relationship between the speed of sound, frequency, and wavelength
in an ultrasound wave?
o Answer: The speed of sound © is equal to the product of frequency (f) and wavelength (λ): ( c =
f \times \lambda ).

Imaging Principles
4. Multiple Choice: What is the primary advantage of using phased array transducers in ultrasound
imaging?
o A) Improved penetration depth
o B) Ability to steer the beam electronically
o C) Higher resolution
o D) Reduced cost
o Correct Answer: B) Ability to steer the beam electronically
o Explanation: Phased array transducers can electronically steer the ultrasound beam, allowing for
dynamic focusing and better imaging of moving structures.
5. True/False: Lateral resolution in ultrasound imaging is primarily determined by the beam width.
o Answer: True
o Explanation: Lateral resolution depends on the width of the ultrasound beam; narrower beams
provide better lateral resolution.
6. Short Answer: Explain the concept of lateral resolution and how it can be improved in
ultrasound imaging.
o Answer: Lateral resolution is the ability to distinguish two structures that are side by side. It can
be improved by using higher frequency transducers and focusing the ultrasound beam.

Doppler Effect
7. Multiple Choice: What is the primary limitation of pulsed wave Doppler in measuring high
blood flow velocities?
o A) Aliasing
o B) Low resolution
o C) High cost
o D) Limited penetration
o Correct Answer: A) Aliasing
o Explanation: Pulsed wave Doppler can experience aliasing when measuring high velocities,
leading to incorrect velocity readings.
8. True/False: The Doppler shift is directly proportional to the velocity of the moving blood cells.
o Answer: True
o Explanation: The Doppler shift increases with the velocity of the moving blood cells, allowing
for the calculation of blood flow velocity.
9. Short Answer: Describe the principle of power Doppler and its clinical applications.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Estonloyford. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $35.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79079 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$35.99
  • (0)
  Add to cart