100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
IEC FINAL EXAM YEAR 1, 2, 3 AND 4 EXAMS | ALL QUESTIONS AND CORRECT ANSWERS | ALREADY GRADED A+ | LATEST VERSION | VERIFIED ANSWERS $27.99   Add to cart

Exam (elaborations)

IEC FINAL EXAM YEAR 1, 2, 3 AND 4 EXAMS | ALL QUESTIONS AND CORRECT ANSWERS | ALREADY GRADED A+ | LATEST VERSION | VERIFIED ANSWERS

 5 views  0 purchase
  • Course
  • IEC 2025
  • Institution
  • IEC 2025

IEC FINAL EXAM YEAR 1, 2, 3 AND 4 EXAMS | ALL QUESTIONS AND CORRECT ANSWERS | ALREADY GRADED A+ | LATEST VERSION | VERIFIED ANSWERS

Preview 4 out of 185  pages

  • September 19, 2024
  • 185
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • IEC 2025
  • IEC 2025
avatar-seller
StudyWay
IEC FINAL EXAM YEAR 1, 2, 3 AND 4 EXAMS |
ALL QUESTIONS AND CORRECT ANSWERS |
ALREADY GRADED A+ | LATEST VERSION |
VERIFIED ANSWERS
IEC FINAL EXAM YEAR 1

Which of the following is a 3/0 AWG conductor?

a.0000
b.000
c.0
d.00 ------CORRECT ANSWER---------------b. 000



For purposes of calculating a residential service, the general-purpose
lighting load is calculated at ___ per square foot of area.

a.1,500 watts
b.2 volt-amperes
c.3 volt-amperes
d.1 volt-ampere ------CORRECT ANSWER---------------c. 3 volt-amperes



When calculating residential service load, ___ is allowed for each branch
circuit serving laundry receptacles.

a.1,500 volt-amperes
b.2,000 volt-amperes
c.1,920 watts
d.1,440 watts ------CORRECT ANSWER---------------a. 1,500 volt-amperes

,For a 125-Amp, 120/240-V, 3W residential service, ___ AWG copper
THHN/THWN conductors are the smallest permitted for the ungrounded
conductors.

a.1
b.4
c.3
d.2
e.none of these ------CORRECT ANSWER---------------d. 2

NEC Table 310.12



Loads, such as heating and air conditioning, that do not operate at the
same time are said to be noncoincident loads. While separate circuits must
be designed to serve each load, when calculating service load only the ___
of two noncoincident loads needs to be included.

a.larger
b.smaller ------CORRECT ANSWER---------------a. larger



When calculating the size of the required service, you should consult
household electric clothes dryer demand factors given in Table ___.

a.220.54
b.220.12
c.220.55
d.220.42
e.220.56 ------CORRECT ANSWER---------------a. 220.54




What is the result if the neutral wire becomes open on a multiwire circuit
having unequal loads?
a.
The load of higher resistance would overheat and probably be damaged.

,b.
The load of lesser resistance would overheat and probably be damaged.
c.
No effect until one load is turned off or opens.
d.
No effect. ------CORRECT ANSWER---------------a.
The load of higher resistance would overheat and probably be damaged.



Circuits 7 and 9 share a neutral. This is a multiwire branch circuit. If Ckt. 7
is drawing 13 amps and Ckt. 9 is drawing 16 amps, how much current is
flowing in the neutral?

a.3
b.13
c.29
d.16 ------CORRECT ANSWER---------------3 Amps



The Code reference that specifies the type of disconnecting means (circuit
breaker for example) that can be used on a multiwire branch circuit that
feeds devices mounted on the same yoke [a stack switch or a duplex
receptacle for example] is ___.Note: Select N/A (not applicable) if there is
not an NEC® requirement.

a.Article 100
b.240.15(B)(1)
c.404.8(A)
d.N/A ------CORRECT ANSWER---------------b. 240.15(B)(1)



Voltmeters are connected in ___ with the load when used to measure
voltage across a load in a circuit. ------CORRECT ANSWER---------------
Parallel

, The neutral has been removed from the neutral bar in the circuit shown in
Figure 128.407. Lamp 3 is connected in ___ with Lamps 1 and 2. ------
CORRECT ANSWER---------------Series
(3 wire parallel circuits turn to series when the neutral is disconnected from
the neutral bar)



What is the minimum number of receptacles required in an unfinished
basement?

a.2
b.4
c.1
d.0 ------CORRECT ANSWER---------------c. 1



The overall diameter (including insulation) of a 250 kcmil THHN/THWN
copper conductor is ___ inches?

a..082
b..397
c..765
d..711
e..575 ------CORRECT ANSWER---------------d. 711

NEC Chapter 9 Table 5 pg 701



What part of the NEC® is a reference for calculating conduit fill where all
conductors are the same size?

a.Article 100
b.Table 310.15(B)(16)
c.Annex C
d.Table 314.16(A) ------CORRECT ANSWER---------------c. Annex C

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller StudyWay. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $27.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76799 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$27.99
  • (0)
  Add to cart