100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
MICR221 EXAM QUESTIONS WITH COMPLETE SOLUTIONS $13.79   Add to cart

Exam (elaborations)

MICR221 EXAM QUESTIONS WITH COMPLETE SOLUTIONS

 8 views  0 purchase
  • Course
  • MICR221
  • Institution
  • MICR221

MICR221 EXAM QUESTIONS WITH COMPLETE SOLUTIONS Define death of microorganisms - Answer-Loss of ability to multiply under any known conditions Define sterilisation - Answer-Complete removal or destruction of all microorganisms from inanimate objects. Non-selective physical and chemical method...

[Show more]

Preview 3 out of 22  pages

  • August 29, 2024
  • 22
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • micr221
  • MICR221
  • MICR221
avatar-seller
Perfectscorer
MICR221 EXAM QUESTIONS WITH
COMPLETE SOLUTIONS
Define death of microorganisms - Answer-Loss of ability to multiply under any known
conditions

Define sterilisation - Answer-Complete removal or destruction of all microorganisms
from inanimate objects.
Non-selective physical and chemical methods

Define disinfection - Answer-Destruction or removal of microorganisms (but not bacterial
endospores) on inanimate objects by physical or chemical methods

Define antisepsis - Answer-Chemicals applied to body surfaces to destroy or inhibit
growth of microorganisms within host tissues

Explain the difference between bacteriocidal and bacteriostatic - Answer-Bacteriocidal =
kills, decrease in numbers
Bacteriostatic = inhibits, numbers remain the same

List some physical control methods - Answer-Moist heat: Autoclave, Boiling H2O,
Pasteurisation
Dry heat: Flaming and incineration, Hot air oven, Freezing (not as effective, does not kill
cells)
Filtration
Radiation (ionising and non-ionising)

Explain the difference between batch, flash, UHT pasteurisation - Answer-Done by a
plate heat exchanger which uses steam
Batch = 63 degrees C, 30 mins
Flash = 71 degrees C, 15 secs
Ultra high temp milk = 140 degrees C, minimum of 1 sec

Autoclaving - Answer-Steam is important because the pressure raises the boiling point
of water so that steam with a higher temp is produced. Pure steam and no air is crucial,
it denatures the key enzymes and essential proteins which leads to cell death (temp is
121dc) mixed air and steam (temp is 112dc)
Need to consider both temp and time, pressure = 15psi

What can you sterilise using an autoclave? - Answer-Culture media, glassware, surgical
items, materials from the lab for safe disposal

,What can't be autoclaved? - Answer-Plastics, toxic chemicals, heat-liable compounds
(antibiotics), heat sensitive equipment

Describe the relationship between death and temperature - Answer-Death is an
exponential function and thus occurs more rapidly as heat is raised
To sterilise or reduce a population it will take longer at lower temperatures than at
higher temperatures

What is the importance of a control? - Answer-For comparison, to test if the organism is
viable and to see if the treatment is effective

Explain what the thermal death point is - Answer-The lowest temperature required to kill
all cells in a standard suspension of bacteria in a liquid culture within 10 minutes

What is the method for determining the thermal death point? - Answer-Bacteria are
exposed for the same amount of time to different temperatures, the agar plate is
inoculated and the lowest temp with no growth = thermal death point

Explain what the thermal death time is - Answer-The length of time required to kill all of
the cells in a standard suspension of bacteria in a liquid culture at a given temperature

What is the method for determining the thermal death time? - Answer-Bacteria are
exposed at the same temperature but for differing amounts of time, the agar plate is
inoculated and the shortest time period with no growth = thermal death time

What is the decimal reduction time? - Answer-The length of time taken to obtain a ten-
fold reduction in the number of bacteria in a standard suspension of bacteria in a liquid
culture
-10 fold reduction = 90% killed = 1 log difference
-Measured in a 60 degree water bath
(see graphs in book)

What is the death rate constant? - Answer-K = 2/3t x log10 (Nt/No)
Shape of the curve

What is the Z value? - Answer-The temperature required for one log10 reduction in the
D value (track across from two log reduction with the difference of one, and down on the
x axis to minus the temperature difference)

Filtration - Answer-Filtration through filter with pores too small for for microorganisms
but large enough to allow liquid or air to pass through
Pore size is usually 0.2um to filter out bacteria (0.0um for myocoplasma - doesnt have a
cell wall so very flexi and can squeeze through the larger pores

Describe the depth filter - Answer-Random array of overlapping fibres, thick/deep (5-
10mm from top to bottom) usually made from glass or asbestos

, What are the advantages of a depth filter? - Answer-High dirt handling capacity, good
for highly contaminated solutions, can trap a lot of bacteria

What are the disadvantages of a depth filter? - Answer-Retains a lot of fluid (lost within
the filter), bad if it is an expensive solution - such as antibiotics

Describe the membrane filter - Answer-More regular pores, very thin, made from
cellulose acetate or cellulose nitrate

What is the advantage of a membrane filter? - Answer-Doesn't retain liquid

What are the disadvantages of a membrane filter? - Answer-Acts as a sieve, bacterial
contaminants collect on the surface of the filter causing blockages

Describe a nucleopore filter - Answer-Very clear pores, low numbers of pores per filter,
polycarbonate films are processed to make sure they have uniform pores

What is the advantage of the nucleopore filter? - Answer-Can be used to prepare
samples for electron sacnning microscopy

What is the disadvantage of the nucleopore filter? - Answer-Not many pores therefore a
much slower flow rate

Give some examples of solutions that can be filtered - Answer-Tissue culture media,
serum, antibiotic solutions, gases, filtered beer, observation of microbes from pond
water

What is a HEPA filter? - Answer-Laminar flow hood for basic specimen protection
Class 2 biological safety cabinets (for protecting specimen, user and environment from
contamination)

Describe non-ionising radiation - Answer-Applications include the sterilisation of
benches, air, water/waste water (in thin streams)
Not used to serilise large volumes of water as it cannot penetrate to a significant depth

eg. UV radiation = wavelength 260nm damages the DNA in the cell by forming
pyramidine dimers (thymine dimers-covalent chemical bonds, conformational change
resulting in death) or direct protein damage

What is the SOS response? - Answer-Error prone repair mechanism

Normal = no thymine dimers, LexA protein represses the production of SOS repair
enzymes (negative feedback system)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Perfectscorer. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.79. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.79
  • (0)
  Add to cart