2024 BICSI –RETAKE PRACTICE
TEST EXAM WITH CORRECT
ANSWERS


The type of cutover where cross-connects are relocated one pair after
another until completed is called a - CORRECT-ANSWERSrolling cut 11-28

What is the width of the SBB? - CORRECT-ANSWERS2" (8-11, 8-16)

The _______ is a copper conductor that interconnects the SBB to the PBB -
CORRECT-ANSWERSTBB (8-11, 8-16)

The ________ bonds the electrical systems grounding electrode system to the
PBB. - CORRECT-ANSWERSTBC (8-11, 8-16)


The 2 main considerations concerning the existing cabling are? - CORRECT-
ANSWERSGrandfathered system
Abandoned cable 11-25

The ________ is the conductor used to connect the busbar to the ac electrical
panelboards - CORRECT-ANSWERSACEG (8-11, 8-16)

The recommended maximum value for the bonding resistance between the
grounding electrode and the busbar in the EF or TR is _______ milliohms -
CORRECT-ANSWERS100

Cabinets and racks should be set in place and leveled throughout the lineup.
Leveling foot adjustments or shimming of any anchoring point should not
exceed _______ inch(es) unless specified by the project engineer. - CORRECT-
ANSWERS0.5

The recommended minimum separation distance from electric motors and
transformers is ______ inches - CORRECT-ANSWERS48

Where optical fibers will be used, consider placing three innerducts ( two
_____ and one ____) inside each 4" conduit designated for this purpose to
ensure physical cable protection - CORRECT-ANSWERS1.5"
1"

, The minimum bend radius for coaxial cable (semi-rigid) is _________ time the
cable diameter - CORRECT-ANSWERS20

The minimum bend radius for intra-building optical fiber cable during
installation is _______ times the cable diameter. - CORRECT-ANSWERS15

The maximum pull force for two- to- four strand optical fiber is ______lbf -
CORRECT-ANSWERS50

Multipair copper cables require a minimum bend radius of _______ times their
diameter - CORRECT-ANSWERS10

*________ is a property of an electromagnetic field built around a conductor
that opposes any changes in current flow in a circuit. - CORRECT-
ANSWERSInductance

_______ is a property of conductors that allows storage of electrical charges
when potential differences ( voltages) exist between the conductors. -
CORRECT-ANSWERSCapacitance

The frequency of Category 8 cable is ______ - CORRECT-ANSWERS2000 MHz

Series _____ is the preferred choice for longer coaxial runs - CORRECT-
ANSWERS11

You would look in ANSI/TIA - _______ if you needed information on the labeling
standard - CORRECT-ANSWERS606

NEC ________ says that communication wires and cables shall be listed -
CORRECT-ANSWERS800

Commercial Building Telecommunications Infrastructure Standard -
CORRECT-ANSWERS568.1

The _______ provides space for an EF - CORRECT-ANSWERSEquipment room
(ER)

The color field for the "Common Equipment" termination field is _________ -
CORRECT-ANSWERSPurple

________cabling is the portion of the telecommunications cabling system that
connects the work areas to the other telecommunications spaces - CORRECT-
ANSWERSHorizontal

For all new installations, multipair backbone must meet the minimum
performance of category ______ cable - CORRECT-ANSWERS5e

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Elitaa. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.99
  • (0)
  Add to cart