CT Registry Review Questions and Correct Answers Iothalamate meglumine - Correct Answer aka Conray; Ionic radiopaque contrast media (RCM) An average range for activated PTT - Correct Answer 25-35 seconds Which of the following is the correct angle of insertion for placing a butterfly needle ...

[Show more]

Preview 4 out of 38  pages

  • August 19, 2024
  • 38
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • iothalamate meglumine
  • CT REGISTRY
  • CT REGISTRY
avatar-seller
Winfred
CT Registry Review Questions and Correct
Answers
Iothalamate meglumine - Correct Answer aka Conray; Ionic radiopaque contrast media (RCM)



An average range for activated PTT - Correct Answer 25-35 seconds



Which of the following is the correct angle of insertion for placing a butterfly needle into a vein for
intravenous of a contrast agent - Correct Answer 15 degrees



A total volume of 125mL of an iodinated contrast agent is administered intravenously via automatic
injector in 50 seconds. The flow rate for this injection is: - Correct Answer 2.5 mL/sec



Tachycardia, rapid, shallow breathing, cyanosis are symptoms of what? - Correct Answer Symptoms a
patient in shock may exhibit



The drug SOLU-CORTEF may be classified as - Correct Answer Corticosteroid



Iohexol (ionic or non-ionic?) - Correct Answer Non-ionic contrast material



Ionization chamber - Correct Answer Device used to measure patient dose



T wave - Correct Answer Portion of the cardiac cycle on an electrocardiogram (Ekg) that corresponds
to complete cardiac diastole



CT arthrography - Correct Answer Iodinated contrast is injected directly into the joint space



Iodixanol - Correct Answer aka Visipaque; Iso-osmolar contrast media (IOCM)



Contrast-induced nephrotoxicity (CIN) - Correct Answer Serious decline in renal function following IV
contrast injection



what is Effective dose - Correct Answer Quantity of absorbed radiation dose based on the
radiosensitivity of a particular tissue type

,Advantages of a saline flush immediately following IV contrast - Correct Answer 1. Reduction in
contrast agent dose

2. Reduction in incidence of contrast-induced nephrotoxicity (CIN)

3. Reduction in streaking artifact due to dense contrast agent in the vasculature .



Factors that may affect a patient's calculated glomerular filtration rate? - Correct Answer Age, sex,
race



Medicine administered to dilate the coronary vasculature prior to a cardiac CT exam - Correct Answer
Sublingual nitroglycerin



Normal diastolic blood pressure in an adult - Correct Answer 60-90 mm Hg



Methods to reduce radiation dose to pediatric patients - Correct Answer 1. Reduce mA

2. Limit phases of acquisition (INSTEAD OF W/WO JUST DO W.)

3. Increase pitch



Relationship of radiation exposure and it's potentially harmful effects; stochastic= - Correct Answer
randomly determined; having a random probability distribution or pattern that may be analyzed
statistically but may not be predicted precisely.



Isolation technique that protects against infection through fecal material - Correct Answer Enteric
precautions



Conray aka - Correct Answer Iothalamate meglumine



Omnipaque aka - Correct Answer Iohexol



Isovue aka - Correct Answer Iopamidol



Optiray aka - Correct Answer Ioversol

,CTDIw - Correct Answer The radiation dose index calculation that takes into account the variations in
absorption across the field of view due to beam hardening



Direct contraindications to the administration of Iodinated contrast material include - Correct Answer
prior life threatening reaction

Multiple myeloma

Diabetes



Unit used to express the total patient dose from a helically acquired CT examination - Correct Answer
mGy-cm (milligrays per centimeter)



Components of a comprehensive CT stroke management protocol. - Correct Answer 1.Pre-contrast
sequence of the brain

2. CTA of the brain and carotids

3. CT perfusion (CTP) of the brain



Pleural effusion - Correct Answer An abnormal density located in lung field; has an attenuation value
of +5.0 Houndsfield units



Average attenuation value of simple cyst of the kidney - Correct Answer 0 to +20 Houndsfield units



After initiation of rapid bolus administration of an iodinated contrast agent, the arterial phase of
hepatic contrast enhancement occurs at approximately - Correct Answer 25-30 seconds



The abdominal aorta bifurcates at the level of - Correct Answer L4



On an ECG of the complete cardiac cycle, at which portion on the R-R interval is the heart muscle in
diastole - Correct Answer 55%-75%



The accumulation on gas within a degenerating intervertebral disc is called the - Correct Answer
vacuum phenomenon



During a spiral or helical CT examination, the scanner acquires data - Correct Answer 1. continuously
as the patient travels through the gantry

, 2. in the form of a complete volumetric data set



Which of the following CT studies of the head is typically performed without a contrast agent? -
Correct Answer CT of the brain to r/o subdural hematoma



Phase of renal contrast enhancement that best demonstrates transitional cell carcinoma (TCC) of the
bladder - Correct Answer Excretory



CT examinations of the abdomen are often performed in the right lateral decubitus position to
demonstrate the relationship between the: - Correct Answer Duodenum and the pancreatic head



The section width and spacing for a general survey CT of the neck - Correct Answer 3 mm thick every
3mm



The still viable ischemic cerebral tissue that surrounds the infarct core in a patient with an acute
stroke - Correct Answer Ischemic penumbra



divergent beam - Correct Answer beam does not stay on same path



heterogenuous energy - Correct Answer All the beams coming from the x ray tube are of various
energies



Noise - Correct Answer Scatter adds density (noise)...low photon energy = scatter



Gantry contains: - Correct Answer 1. Tube

2. Detector

3. Collimator

4. Physical filters--absorbs lower energy photons

a. water bath

b. collimator (stops beam from diverging)

c. bow tie filter (removes noise)



Low voltage generator - Correct Answer Located outside of the tube

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Winfred. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days