Which of the following is a single-stage fire pump designed to fit into the intake/discharge line with the
driver located above the inline impeller? (534) ANS - Vertical inline



Fire loss data reveals that in buildings equipped with automatic sprinklers, about _____ percent of all
fires were controlled or extinguished by the sprinkler system. (504) ANS - ninety-four



For which fire pump are the impellers actually located within the water supply source? (534) ANS -
Vertical turbine



Which controller monitors and contains alarms for conditions such as low engine oil pressure and high
engine coolant temperature? (537) ANS - Diesel engine controller



Large buildings having two or more zones require a fire department connection (FDC): (531) ANS - for
each zone.



Which type of sprinkler is recessed and covered with a removable decorative cover plate that releases
when exposed to a specific level of heat? (512) ANS - Concealed



Which of the following is a factor that determines the minimum waterflow required for an automatic
sprinkler system? (508) ANS - Hazard being protected



Which type of sprinkler is designed for fast response in residential occupancies where life safety in the
room of origin is the primary concern? (515) ANS - Residential



Which automatic sprinkler system is continually charged with compressed air and when a sprinkler
activates, the air is released, allowing the water-flow control valve to operate and charge the system
with water? (505) ANS - Dry-pipe sprinkler system



Which of the following is the most common method for driving a fire pump? (535) ANS - Electric motor

, Which of the following is a component of standpipe and hose fire suppression systems? (526) ANS -
Pressure-regulating device



Which type of sprinkler is normally provided in a deluge sprinkler system? (515) ANS - Open



Which are vertical sections of pipe that connect the underground supply to the rest of the piping in the
system? (510) ANS - System risers



Thermally sensitive devices such as fusible links keep most sprinklers closed and when heat from a fire
affects these devices: (504) ANS - sprinklers closest to the fire activate automatically.



Which pressure-regulating device at a hose outlet is preferred for managing excessive pressure and is
considered to be the most reliable method of pressure control? (531) ANS - Pressure-control devices



Which type of sprinkler systems operate when an electronic detector or manual control device is
activated? (504) ANS - Deluge or preaction sprinkler systems



Which classification of standpipe and hose systems is designed to be used by both fire department
personnel and trained building occupants? (526) ANS - Class III



Which fire protection system discharges water over the area or surface of electrical equipment to be
protected through an arrangement of pipes and nozzles? (520) ANS - Water-spray fixed system



Water-mist fire suppression systems are designed to be operated at: (522) ANS - considerably higher
pressures than standard sprinkler systems.



Which classification of standpipe and hose fire suppression systems has both 2½-inch (65 mm) hose
connections and 1½-inch (38 mm) hose connections? (526) ANS - Class III



Which detection and activation device sounds a warning when a sprinkler activates and water begins to
flow? (517) ANS - Waterflow alarm

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Professorkaylee. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75759 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.49
  • (0)
  Add to cart