100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
EPA 608 EXAM QUESTIONS AND ANSWERS $15.49   Add to cart

Exam (elaborations)

EPA 608 EXAM QUESTIONS AND ANSWERS

 3 views  0 purchase
  • Course
  • EPA608
  • Institution
  • EPA608

EPA 608 EXAM QUESTIONS AND ANSWERS

Preview 2 out of 10  pages

  • August 17, 2024
  • 10
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • EPA608
  • EPA608
avatar-seller
biggdreamer
EPA 608 EXAM QUESTIONS AND
ANSWERS
On low pressure chillers, moisture typically enters the refrigerant system through -
Answer-air leaks from areas with gaskets or fittings

The maximum test pressure for leak testing a low pressure centrifugal is: - Answer-10
psig

Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11
chiller - Answer-...

A hydrostatic tube test kit is used to: - Answer-determine if a tube leaks

Commercial and industrial process refrigeration systems must be repaired when the
leak rate exceeds ____ of the charge per year. - Answer-35%

Refrigerant recovery typically start with liquid recovery it is faster. - Answer-...

A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - Answer-
15 psig

According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm
Hg to a level above ____ during a standing vacuum test, the system should be checked
for leaks. - Answer-2.5 mm Hg

The primary water source for a recovery unit condensing coil is _____. - Answer-local
municipal water supply

When recharging a refrigeration system with R-11, what vaporpressure is necessary in
the shells before changing with liquid? - Answer-16.9" Hg vacuum

After recovering the liquid refrigerant you must: - Answer-recover the vapor refrigerant

According to the EPA there is approximately _____ refrigerant vapor left in an average
350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. -
Answer-100 pounds

Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg
vacuum can cause the: - Answer-system water to freeze

A system does not have to be evacuated all the way to the required level when: -
Answer-leaks in the appliance make evacuation to the prescribed level unattainable

, Which of the foloowing repairs would ALWAYS be considered "major" under EPA's -
Answer-replacement of evaporator coil

Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the
purpose of opening the system for a non major repair? - Answer-warming the refrigerant

If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate
an low pressure appliance to _______ before making a major repair. - Answer-25 mm of
Hg absolute

After reaching the required recovery vacuum on a chiller, you should - Answer-Wait for
at least a few minutes to see if the system pressure rises, indicating that there is till
refrigerant in a liquid form or in the oil

The pressure corresponding to 32 F for R-123 - Answer-20 inches of HG vacuum

When evacuating a system the use of too large a vacuum pump can cause? - Answer-
trapped water to freeze

Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: -
Answer-35F

During the evacuation of a system containing large amounts of moisture you can
prevent freezing of this moisture by increasing the pressure with______gas - Answer-
nitrogen

ASHRAE standard 15-1994 requires that each machinery room must activate an alarm
and mechanical ventilation beofre refrigerant concentrations exceed: - Answer-the
threshold limit valve and time weighted average

The typical design burst pressure for a rupture disk on a low pressure centrifugal air-
conditioning system is set at_______ - Answer-15 psi

Heat pumps that have been retrofitted from R22 to R407C should be leak checked with:
- Answer-pressurized nitrogen

When a new system has been assembled, the first thing to do is: - Answer-pressurize
the system with inert gas and leak check

EPA regulations require that leaking commercial or industrial process refrigeration
equipment must be repaired when the leak rate exceeds______ of the charge per year.
- Answer-35%

Prior to replacing the condenser coil in a high pressure system, the refrigerant was
recovered and stored in a refillable container. The refrigerant: - Answer-can probably be
charged back into the system

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller biggdreamer. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $15.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76799 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$15.49
  • (0)
  Add to cart