100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ARMRIT UPDATED Exam Questions and CORRECT Answers $9.49   Add to cart

Exam (elaborations)

ARMRIT UPDATED Exam Questions and CORRECT Answers

 8 views  0 purchase
  • Course
  • ARMRIT
  • Institution
  • ARMRIT

ARMRIT UPDATED Exam Questions and CORRECT Answers Different tissues that have signals that appear similar on an MR image are described as: A) hypointense B) hyperintense C) isointense D) isodense - CORRECT ANSWER- isointense in a large main magnetic field such as those employed in MRI, the ...

[Show more]

Preview 4 out of 51  pages

  • August 9, 2024
  • 51
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ARMRIT
  • ARMRIT
avatar-seller
MGRADES
ARMRIT UPDATED Exam Questions and
CORRECT Answers

Different tissues that have signals that appear similar on an MR image are described as:
A) hypointense
B) hyperintense
C) isointense
D) isodense - CORRECT ANSWER- isointense


in a large main magnetic field such as those employed in MRI, the motion of a hydrogen
proton has been described as wobbling like a spinning top. this motion is called
A) precession
B) resonance
C) frequency
D) angular momentum - CORRECT ANSWER- precession


magnetic resonance imaging is derived from the process known as:
A) magnetic resonance angiography
B) magnetic relaxation imaging
C) nuclear magnetic resonance
D) nuclear resonance imaging - CORRECT ANSWER- nuclear magnetic resonance


Once the nmv has moved away from equilibrium, the following will occur
A) the longitudinal component will increase
B) the transverse component will decrease
C) the longitudinal component will stay the same
D) the transverse component will increase - CORRECT ANSWER- the transverse component
will increase


In MR, substances respond to a specific radio frequency which is known as:

,A) magnetic frequency
B) radio frequency
C) gyro-magnetic frequency
D) resonance frequency - CORRECT ANSWER- resonance frequency


the introduction of gadolinium based contrast enhancement agents by intra-venous injection
can involve passing through an abnormal blood brain barrier. the tissue compartments
involved are the:
A) intravascular to interstitial
B) extracellular to intracellular
C) hepatobiliary to renal
D) extradural to renal - CORRECT ANSWER- intravascular to interstitial


t2 is the measurement of time fot the transverse component of the NMV to decrease what
percentage of its maximum value after the application of a 90 degree radio-frequency pulse
A) 33%
B) 63%
C) 37%
D) 67% - CORRECT ANSWER- 37%


in the USA, the MRI system's magnetic field and vector that represents it is symbolized:
A) B1
B) B2
C) B3
D) B0 - CORRECT ANSWER- B0


The resonance frequency of any substance in a magnetic field can be calculated by employing
the
A) damadian equation
B) larmor equation
C) faraday equation
D) lauterbur equation - CORRECT ANSWER- Larmor equation

,in a pulse sequence, transmitting an initial 90 degree radio-frequency pulse will cause the
NMV to:
A) remain at equilibrium
B) shift in both size and direction
C) move to antiparallel
D) rephase - CORRECT ANSWER- shift in both size and direction


Which type of electromagnetic coils are designed to stimulate and detect an MR signal?
A) gradient coils
B) radio-frequency coils
C) shim coils - CORRECT ANSWER- radio-frequency


tissues that are less efficient at spin-spin interactions because they contain more free water,
such as CSF, should have
A) High T2 values and produce hypointense signals
B) HIgh T2 values and produce hyperintense signals
C) low T2 values and produce hypointnese signals
D) low T2 values and produce hyperintense signal - CORRECT ANSWER- High T2 values
and produce hyperintense signals


magnetism can be defined as the ability of certain substances to attract:
A) Copper, aluminum, tin
B) Iron, cobalt, nickel
C) Bronze, niobium, titanium
D) Neodymium, niobium-titanium, lodestone - CORRECT ANSWER- Iron, cobalt, nickel


the purpose of magnetic resonance angiography is to image the:
A) stationary soft tissue
B) blood flow
C) vessel lumen

, D) only abnormal vessels - CORRECT ANSWER- blood flow


the strength of very large magnetic fields like those employed in MRI systems, the SI unit
most commonly used is:
A) Tesla
B) Gauss
C) Kilogauss
D) militesla - CORRECT ANSWER- Tesla


the larmor frequency of hydrogen protons in a 1.5 tesla magnetic field is:
A) 6.4 MHZ/Tesla
B) 12.8 MHz/Tesla
C) 25.5 MHz/tesla
D) 63.9 MHz/tesla - CORRECT ANSWER- 63.9 MHz/Tesla


In MR imaging, for chemical substance to be affected by the main magnetic field and the
radio-wave it must contain an:
A) Odd number of electrons
B) Odd number of total protons and neutrons
C) Even number of total electrons and neutrons
D) even number of protons - CORRECT ANSWER- Odd number of total protons and
neutrons


A 1.5T magnetic field is equal to:
A) 150 gauss
B) 1500 gauss
C) 15,000 gauss
D) 150,000 gauss - CORRECT ANSWER- 15,000 gauss


the components of the gyromagnetic ratio are:
A) stimulation to relaxation

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller MGRADES. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.49
  • (0)
  Add to cart