Chapter 39 - Aerosol Drug Therapy (121: Test 2)
Questions with Correct Answers
Most modern jet nebulizers are powered by? Correct Answer-High
pressure air or oxygen
This is the medication that remains in the SVN after the device stops
generating aerosol and "runs dry". Correct Answer-Residual Drug
Volume (Dead Volume)
The residual drug volume (of a 3 ml dose of drug) can range from:
Correct Answer-0.5 - 2.2 ml of drug
The more drug available to be turned to aerosol in an SVN, the
________ % of the drug that remains as residual volume. Correct
Answer-less
With higher flow of gas to the nebulizer, the particle size generated is
__________ and the time required for nebulization is ___________.
Correct Answer-smaller and shorter
What happens if gas flow or pressure to a nebulizer is too low? Correct
Answer-This can result in negligible nebulizer output (not enough
aerosol will be produced)
,True/False: Repeated use of nebulizers causes output to become less
efficient. Correct Answer-False: output is not effected in reused
nebulizers as long as the nebulizer was cleaned properly.
Gas density affects what two things? Correct Answer-1. Aerosol
Generation
2. Gas delivery to the lungs
What are the 3 characteristics of drug formulation that can affect
performance of SVN's? Correct Answer-1. Viscosity
2. Surface Tension
3. Homogeneity
What 2 things can affect particle size and concentration of the drug
remaining in a small volume neb? Correct Answer-Humidity and
Temperature
What are the four categories of jet SVN's? Correct Answer-1. continuous
nebulizer w/ simple reservoir
2. continuous nebulizer with collection reservoir bag
3. breath-enhanced nebulizer
4. breath-actuated nebulizer
What is the most commonly used SVN? Correct Answer-Constant
Output Nebulizer
, True/False: The constant output nebulizer wastes medication when
compared to other nebs. Correct Answer-True: because aerosol is
constantly produced throughout the patient's breathing cycle, some of it
gets wasted.
True/False: aerosolization past the point of initial sputter is generally
considered useless. Correct Answer-True
Why do many clinicians prefer not to use a mask for SVN therapy?
Correct Answer-Because the nose works as an efficient filter of particles
larger than 5 μm.
A concern with continuous bronchodilator therapy is ________? Correct
Answer-increased drug concentration (which can cause drug toxicity
over time).
What does SPAG stand for? Correct Answer-Small Particle Aerosol
Generator
What was the SPAG originally developed for? Correct Answer-Studying
pathogenic aerosols
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller cracker. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $14.99. You're not tied to anything after your purchase.