1. Buckling in horizontal vinyl siding is generally caused by
A. reflected sunlight.
B. improper fastening.
C. condensation in walls.
D. improper house wrap. -
2. At what level would water pressure within a single-fa...
at what level would water pressure within a single
Written for
FPT University
MKT 101 (MKT101)
All documents for this subject (1)
Seller
Follow
docguru
Reviews received
Content preview
NHIE 100 QUESTIONS WITH CORRECT
ANSWERS A+ GRADED
1. Buckling in horizontal vinyl siding is generally caused by
A. reflected sunlight.
B. improper fastening.
C. condensation in walls.
D. improper house wrap. - answer improper fastening
2. At what level would water pressure within a single-family dwelling begin to be
considered excessive and require correction?
A. 60 psi
B. 80 psi
C. 100 psi
D. 120 psi - answer 80 psi
3. A newer home with electric heat is being inspected. It has a below grade finished
basement containing a bedroom. The inspector should look for a smoke alarm and
A. an escape and rescue opening.
B. a carbon monoxide alarm.
C. a fire extinguisher.
D. a safety ladder. - answer an escape and rescue opening
4. A swimming pool fence must prevent passage of a sphere that is larger than
A. 2 inches.
B. 3 inches.
C. 4 inches.
D. 5 inches. - answer 4 inches
5. Refer to the photograph to answer this question. What should an inspector
recommend to the client regarding the conditions shown in relation to the
downspout/rain leader?
A. Nothing, the downspout is properly installed.
B. Gravel should be installed under the downspout.
,C. The downspout should be moved away from the siding.
D. A contractor should evaluate the downspout and recommend repairs.A contractor
should evaluate the downspout and recommend repairs - answer
6. If water infiltration is suspected behind a finished surface. What tool would be the
best choice to verify dampness?
A. an infrared thermometer
B. a pin-type moisture meter
C. a non-contact moisture meter
D. a digital camera - answer a non-contact moisture meter
7. Gas-fired furnace heat exchangers most often fail from
A. low temperatures.
B. lack of use.
C. improper gas pressure.
D. rust and metal fatigue. - answer rust and metal fatigue.
8. Relative Humidity (RH) is expressed as
A. volume.
B. percentage.
C. capacity.
D. temperature. - answer percentage.
9. Connections of dissimilar metal in a plumbing system, such as galvanized steel pipe
and copper pipe, will usually cause
A. reduced water pressure.
B. decreased water quality.
C. glazed pipes.
D. electrolysis. - answer electrolysis.
10. A Ground fault circuit interrupter (GFCI) is a safety device that
A. disconnects power when the grounding to the outlet is faulty.
B. detects moisture and disconnects power in wet locations.
C. disconnects the power when sensing current leakage to ground.
D. protects against electrical surges and voltage spikes. - answer disconnects the
power when sensing current leakage to ground
11. An electrical system with a fuse on the neutral conductor and on the energized (hot)
conductors
A. is twice as safe as a system where only the energized (hot) conductors are fused.
B. should have the neutral conductor fuse sized to one half the normal ampacity for the
circuit.
C. is overfused up to 50% if used only for lighting.
D. is hazardous and should be corrected. - answer is hazardous and should be
corrected
, 12. To operate a central air conditioner, an electric clothes dryer, and an electric range,
the ampacity
of the service to the house should be AT LEAST
A. 100 amps at 120 volts.
B. 125 amps at 120 volts.
C. 60 amps at 240 volts.
D. 100 amps at 240 volts. - answer D
13. A floor joist in a crawl space has been cut where the toilet drain passes through the
floor. The joists are 2x6 spaced at 16" on center. The inspector should recommend that
A. the buyer monitor the floor. Floor systems such as this have redundant framing and
removal of one joist is insignificant.
B. a contractor should support the cut joist with new piers and posts from below.
C. the cut joist should be headed off to adjacent framing members to distribute the load.
D. a contrator be contacted to determine what is needed and make repairs. - answer D
14. Most problems with concrete are caused at the time of Installation. What single
factor causes the MOST problems?
A. The concrete has insufficient thickness.
B. Too much water is added to the mix.
C. Too much Portland cement is in the mix.
D. The wrong kind of sand is in the mix. - answer B
15. Brick chimneys on older properties with oil heat sometimes curve above the roof
line, with no visible cracks. Which is a possible cause of this curving?
A. settlement of the chimney footing
B. expansion of mortar
C. absence of a cricket flashing at the roof
D. lack of a rain cap on the flue - answer B
16. Which set of building terms do NOT belong together?
A. cripple trimmer, purlin
B. arch, header, lintel
C. rafters, ceiling joists, trusses
D. sheathing, flooring, decking - answer A
17. Which has the LEAST effect on the deflection of a dimen sion lumber floor system?
A joist width
B. joist grade
C. joist species
D. joist spacing - answer A
18. The normal MAXIMUM rise of residential stair treads is
A. 5 114 inches.
B. 7 314 inches.
C. 8 1/2 inches.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller docguru. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $8.49. You're not tied to anything after your purchase.