Which duties can an S-95 Certificate of Fitness holder perform? - Visual Inspections Only - of fire alarm system components and smoke detectors What is the primary purpose of Fire Alarm Systems? - To warn building occupants and transmit signals indicating a fire condition to the Fire Department ...

[Show more]

Preview 2 out of 7  pages

  • November 29, 2023
  • 7
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
  • S95
  • S95
avatar-seller
Preach
S95 Personal Test | 75 Questions with 100% Correct Answers | Verified | Latest Update 2024 Which duties can an S -95 Certificate of Fitness holder perform? - ✔✔Visual Inspections Only - of fire alarm system components and smoke detectors What is the primary purpose of Fire Alarm Systems? - ✔✔To warn building occupants and transmit signals indicating a fire condition to the Fire Department via central station. What is a Fire Alarm signal? - ✔✔The signal initiated by a fire alarm initiating device such as a manual fire alarm pull station, smoke detector, water -flow switch, or any device in which their activation indicates presence of fire. What is a Supervisory Signal? - ✔✔A signal indicating that a system or device being monitored has been compromised or is in an abnormal state. Is the FDNY dispatched for Supervisory Signals? - ✔✔No. The Facility Manager should investigate and correct the supervisory condition indicated by the FACP . What is a Trouble Signal? - ✔✔A signal that indicates a fault with the fire equipment. It must have an audible signal, distinctive from alarm signals What is the maximum number of minutes that routine handling should take? -- from receipt of trouble signal by central station until initiation of the investigation by telephone. - ✔✔FOUR minutes Is the FDNY dispatched for Trouble Signals? - ✔✔No. Trouble Signals aren't indicative of a fire condition. What is an Acknowledge Switch (ACK) ? - ✔✔This switch/button is used to acknowledge alarm, supervisory, or trouble conditions. Why is an Alarm Silence Switch helpful after an evacuation - while the source of alarm is being investigated? - ✔✔This switch/button silences audible and visual devices (sirens, bells, gongs) so it's easier for Emergency Responders to communicate. Which switch/button is pushed once an alarm condition is cleared? - ✔✔The System Reset Switch Smoke Detectors should be cleaned not less than - ✔✔Once every six months How often should Analog Smoke Detectors be cleaned? - ✔✔One week from receipt of an indication that cleaning is needed. How often should Smoke Detectors be tested for smoke entry? - ✔✔Not less than once a year After activation, which type of heat detector self -restores? Which type doesn't? - ✔✔Fixed -Temperature heat detectors: Doesn't self -restore and requires replacement. Rate of Rise heat detectors: self -restore Fire Alarm Circuits' primary power source shouldn't generate electric power exceeding which voltage? - ✔✔277/480 volts All abnormal conditions be investigated and noted where? - ✔✔A bound Log Book Alarm Notification Appliance - ✔✔A fire alarm system component (bell, light, etc.) that issues an audible, tactile, or visual alert. Annunciator - ✔✔A unit containing one or more indicator lamps, alphanumeric displays, etc. in which each indication provides status info about a circuit, condition, or location. ARCS (Auxiliary Radio Communication System) - ✔✔A wireless two -way building communication system for Fire Dept. use only. Accessibility - ✔✔Admitting close approach - not guarded by locked doors, elevation, etc.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Preach. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77988 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.49  6x  sold
  • (0)
  Add to cart