TREC Home Inspector National Exam – HVAC QUESTIONS AND ANSWERS 100% CORRECT A+
4 views 0 purchase
Course
TREC HOME INSPECTOR
Institution
TREC HOME INSPECTOR
TREC Home Inspector National Exam – HVAC QUESTIONS AND ANSWERS 100% CORRECT A+
What is the max TREC will pay? - CORRECT ANSWER-$12,500 per transaction; $30k for each licensee
Number of members on TREC? - CORRECT ANSWER-9; 6 Brokers / 3 Public. The each serve staggered years.
How many membe...
TREC Home Inspector National Exam – HVAC QUESTIONS AND ANSWERS 100% CORRECT A+ What is the max TREC will pay? - CORRECT ANSWER -$12,500 per transaction; $30k for each licensee Number of members on TREC? - CORRECT ANSWER -9; 6 Brokers / 3 Public. The each serve staggered years. How many m embers are on the Texas Real Estate Inspector Committee? - CORRECT ANSWER -9; all professional inspectors for 5yrs. Staggered 6yr terms. 3 members expire Feb 1st in odd -numbered years. How many hours req for renewal of each of the three types of licensees? - CORRECT ANSWER -16, 8, 0 Real Estate Inspector must complete the following 4 requirements. - CORRECT ANSWER -1. Apprentice insp for min of 3 mos 2. Min of 25 insps 3. Completion of 90 hrs of core instruction 4. 70% or better on state exam Professional Insp must complete the following 4 reqs. - CORRECT ANSWER -1. Real Estate Inspector for 12mos 2. Min of 175 insps 3. Additional 38 hrs of instruction 4. 80% or better on exam A soil engineer rates potential change of soil volume by... - CORRECT ANSWER -The plast icity index (PI) Min crawl space opening... - CORRECT ANSWER -18 x 24 Or 22 x 30 with mechanical equipment Treated wood or decay resistant lumber must be used on structural floor joists in a crawl space when closer to ____ inches? - CORRECT ANSWER -18 inche s Structural girders in a crawl space must be made out of treated or decay resistant lumber when closer than ____ to the ground? - CORRECT ANSWER -12 inches Sills or plates which rest on concrete or masonry walls less than ____ above grade must use treated or decay resistant lumber. - CORRECT ANSWER -8 inches Where should anchor bolts be located? - CORRECT ANSWER -Within 12 inches of openings and 6 ft OC thereafter In areas of expansive soils drainage from the roof to the ground surface must be at least ____ from the foundation walls if an approved drainage system is not used. - CORRECT ANSWER -5 ft The maximum that a load bearing wall stud should be cut or notched is ____ ? - CORRECT ANSWER -25% Studs in a non -load bearing partition may be notched to a depth not exceeding ____ % of a single.stud width? - CORRECT ANSWER -40% Minimum dimensions for a bedroom egress window? - CORRECT ANSWER -20 x 24 inches What is the max d istance an emergency egress window can be located from the floor in a bedroom? - CORRECT ANSWER -44 inches from the floor to the sill. In a non -load bearing wall, what pct of a stud may be drilled? - CORRECT ANSWER -60% In a load bearing wall, what pct of a stud may be drilled? - CORRECT ANSWER -40% In a load bearing wall, what pct of a double stud may be drilled? - CORRECT ANSWER -60% (holes must be a min of 5/8" from the edge) What fraction of a floor joist may be bored? - CORRECT ANSWER -1/3 in the end 1/3 - 2" from the top or bottom. (Notching is only 1/4 in the end 1/3). T he door between living space and garage must be ____ thick and fire rating of NLT ____ minutes? - CORRECT ANSWER -1 3/8" and 20min In habitable rooms, windows must be ____ percent of floor s pace? - CORRECT ANSWER -8% Two family dwellings must be separated by wall with a minimum fire rating of ____? - CORRECT ANSWER -1 hour In a non -load bearing wall, how much may a stud be drilled? - CORRECT ANSWER -60% What is maximum distance that a gas valve can be located from a fire place? - CORRECT ANSWER -6 feet and in the same room. What is the minimum depth of a fireplace? - CORRECT ANSWER -20 inches The hearth and hearth extension shall extend a minimum of ____ from the back of the firebox to the end of t he hearth extension. - CORRECT ANSWER -20" + 16" = 36" For mechanical systems, a level working space at least _____________________ inches deep and _____________________ inches wide shall be provided in front of the control side to service an appliance. - CORRECT ANSWER -30"; 30"
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller ShowvinePublishers. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.19. You're not tied to anything after your purchase.