[Show more]In a (direct expansion) evaporator, liquid refrigerant must boil away as close to the end of the coil as possible in order to: - Operate at High Efficiency. 
 
What is one of the main reasons that reciprocating compressors are not 100% efficient? - Clearance Volume 
 
A dirty evaporator and return a...
Preview 1 out of 4 pages
Add to cartIn a (direct expansion) evaporator, liquid refrigerant must boil away as close to the end of the coil as possible in order to: - Operate at High Efficiency. 
 
What is one of the main reasons that reciprocating compressors are not 100% efficient? - Clearance Volume 
 
A dirty evaporator and return a...
Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. - B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
 
Every absorption...
Preview 2 out of 12 pages
Add to cartDefects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. - B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
 
Every absorption...
HVAC Journeyman Test quiz and answers top-rated
Preview 1 out of 2 pages
Add to cartHVAC Journeyman Test quiz and answers top-rated
The maximum horizontal length of a single-wall connector shall be ____ percent of the height of the chimney or vent. 
75% 
Grease filters shall be installed at an angle of not less that ____ degrees from the horizontal and shall be equipped with a drip tray beneath the lower edge of the filters 
45 ...
Preview 3 out of 28 pages
Add to cartThe maximum horizontal length of a single-wall connector shall be ____ percent of the height of the chimney or vent. 
75% 
Grease filters shall be installed at an angle of not less that ____ degrees from the horizontal and shall be equipped with a drip tray beneath the lower edge of the filters 
45 ...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller CleanA. Stuvia facilitates payment to the seller.
No, you only buy these notes for $30.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
77254 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now