Package deal
S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS BUNDLES
S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS BUNDLES
[Show more]S12 sprinkler test, S13 standpipe test, Sprinklers segment 5, S-12 CITYWIDE SPRINKLER SYSTEMS BUNDLES
[Show more]Antifreeze Sprinkler System - CORRECT ANSWER-A wet pipe sprinkler system 
employing automatic sprinklers that are attached to a piping system that contains 
an antifreeze solution and is connected to a water supply. The antifreeze solution 
is discharged, followed by water, immediately upon operatio...
Preview 2 out of 7 pages
Add to cartAntifreeze Sprinkler System - CORRECT ANSWER-A wet pipe sprinkler system 
employing automatic sprinklers that are attached to a piping system that contains 
an antifreeze solution and is connected to a water supply. The antifreeze solution 
is discharged, followed by water, immediately upon operatio...
Automatic Standpipe System - CORRECT ANSWER-A standpipe system that is 
attached to a water supply capable of supplying the system demand at all times 
and that requires no action other than opening a hose valve to provide water at 
hose connections. 
Churning - CORRECT ANSWER-A condition in a centr...
Preview 2 out of 11 pages
Add to cartAutomatic Standpipe System - CORRECT ANSWER-A standpipe system that is 
attached to a water supply capable of supplying the system demand at all times 
and that requires no action other than opening a hose valve to provide water at 
hose connections. 
Churning - CORRECT ANSWER-A condition in a centr...
The pressure difference for the clapper valve to open is ___ to ___ psi. - 
CORRECT ANSWER-2 to 5 psi 
Maintenance on tanks is every ____ ____. - CORRECT ANSWER-3 years 
A sprinkler system is a ____ ____ ____ that uses _____ as the extinguishing 
agent. - CORRECT ANSWER-Fire extinguishing system, wa...
Preview 2 out of 7 pages
Add to cartThe pressure difference for the clapper valve to open is ___ to ___ psi. - 
CORRECT ANSWER-2 to 5 psi 
Maintenance on tanks is every ____ ____. - CORRECT ANSWER-3 years 
A sprinkler system is a ____ ____ ____ that uses _____ as the extinguishing 
agent. - CORRECT ANSWER-Fire extinguishing system, wa...
Questions 
"Fail Safe" when referred to in locks, means - CORRECT ANSWER-that the door 
can be opened if the power fails 
Where does the on-duty Building Evacuation Supervisor report when an alarm is 
activated? - CORRECT ANSWER-To the Fire Command Station ( To act as Fire 
Safety Director when th...
Preview 2 out of 8 pages
Add to cartQuestions 
"Fail Safe" when referred to in locks, means - CORRECT ANSWER-that the door 
can be opened if the power fails 
Where does the on-duty Building Evacuation Supervisor report when an alarm is 
activated? - CORRECT ANSWER-To the Fire Command Station ( To act as Fire 
Safety Director when th...
fire department connection - CORRECT ANSWER-normally on exterior of 
building... FDNY can pump supplemental water into the sprinkler system, 
standpipe, or other system furnishing water for fire extinguishment to supplement 
existing water supplies. 
system control valve - CORRECT ANSWER-valve contr...
Preview 4 out of 41 pages
Add to cartfire department connection - CORRECT ANSWER-normally on exterior of 
building... FDNY can pump supplemental water into the sprinkler system, 
standpipe, or other system furnishing water for fire extinguishment to supplement 
existing water supplies. 
system control valve - CORRECT ANSWER-valve contr...
fire department connection - CORRECT ANSWER-normally on exterior of 
building... FDNY can pump supplemental water into the sprinkler system, 
standpipe, or other system furnishing water for fire extinguishment to supplement 
existing water supplies. 
system control valve - CORRECT ANSWER-valve contr...
Preview 2 out of 10 pages
Add to cartfire department connection - CORRECT ANSWER-normally on exterior of 
building... FDNY can pump supplemental water into the sprinkler system, 
standpipe, or other system furnishing water for fire extinguishment to supplement 
existing water supplies. 
system control valve - CORRECT ANSWER-valve contr...
Personally Supervised - CORRECT ANSWER-Inspection, testing, servicing, and 
other maintenance of sprinkler systems must be -- 
whenever the building/structure is altered - CORRECT ANSWER-When should 
required fire protection systems be extended or altered to maintain and continue 
protection? 
6 - C...
Preview 3 out of 18 pages
Add to cartPersonally Supervised - CORRECT ANSWER-Inspection, testing, servicing, and 
other maintenance of sprinkler systems must be -- 
whenever the building/structure is altered - CORRECT ANSWER-When should 
required fire protection systems be extended or altered to maintain and continue 
protection? 
6 - C...
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO 
DETERMINE QUALIFICATIONS. - CORRECT ANSWER-OWNER 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON 
PREMISES FOR A MIN. OF __________ YEARS. - CORRECT ANSWER-3 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY 
WITH ...
Preview 3 out of 21 pages
Add to cartTHE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO 
DETERMINE QUALIFICATIONS. - CORRECT ANSWER-OWNER 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON 
PREMISES FOR A MIN. OF __________ YEARS. - CORRECT ANSWER-3 
THE BUILDING OWNER SHALL ASSIGN A(N) ____________ TO COMPLY 
WITH ...
Buildings (4.1.1.1) - Shall be inspected (how often) the building owner shall 
ensure that all areas of the building containing water-filled piping shall be 
maintained at a minimum temperature of 40°F and not exposed to freezing 
conditions - CORRECT ANSWERWhen the pump is in operation a small wat...
Preview 4 out of 77 pages
Add to cartBuildings (4.1.1.1) - Shall be inspected (how often) the building owner shall 
ensure that all areas of the building containing water-filled piping shall be 
maintained at a minimum temperature of 40°F and not exposed to freezing 
conditions - CORRECT ANSWERWhen the pump is in operation a small wat...
How often shall the stem of an OS&Y Valve be lubricated - CORRECT 
ANSWER-Annually 
The 3 year dry pipe trip test is to be performed by whom? - CORRECT 
ANSWER-MP & MF SPC 
Fire department connections are to be inspected how often? - CORRECT 
ANSWER-Quarterly 
Water motor gongs are to be tested how ...
Preview 2 out of 12 pages
Add to cartHow often shall the stem of an OS&Y Valve be lubricated - CORRECT 
ANSWER-Annually 
The 3 year dry pipe trip test is to be performed by whom? - CORRECT 
ANSWER-MP & MF SPC 
Fire department connections are to be inspected how often? - CORRECT 
ANSWER-Quarterly 
Water motor gongs are to be tested how ...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Hkane. Stuvia facilitates payment to the seller.
No, you only buy these notes for $17.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
76799 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now