Package deal
EPA 608 study material Package deal
EPA 608 |study material Package deal Compilation | Verified | Guaranteed Success
[Show more]EPA 608 |study material Package deal Compilation | Verified | Guaranteed Success
[Show more]Preview 2 out of 8 pages
Add to cartThe sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. - ️️Restricted to technicians who are EPA certified and refrigerant recovery 
 
A small Pliance is defined as a system that is - ️️Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds...
Preview 2 out of 6 pages
Add to cartThe sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. - ️️Restricted to technicians who are EPA certified and refrigerant recovery 
 
A small Pliance is defined as a system that is - ️️Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds...
Are there drop-in replacements for R-12 systems? Why or why not? - ️️No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
What type of oil is used in R-134a and what oils will it mix with? - ️️Ester based oils and they do not mix with other o...
Preview 2 out of 12 pages
Add to cartAre there drop-in replacements for R-12 systems? Why or why not? - ️️No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
What type of oil is used in R-134a and what oils will it mix with? - ️️Ester based oils and they do not mix with other o...
What are the typical uses of the center port of gauge set? - ️️Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? - ️️Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used on the g...
Preview 3 out of 30 pages
Add to cartWhat are the typical uses of the center port of gauge set? - ️️Used during evacuation, charging and recovery procedures. 
 
What color are the gauges on a manifold gauge set? - ️️Low pressure is blue, High pressure is red. 
 
What are the typical ranges of pressure measurements used on the g...
Refrigeration technicians who violate the Clean Air Act can: - - ️️Lose their EPA certification, be fined, be required to appear in Federal court. 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - - ️️recovery and recycling. 
 
Refrige...
Preview 3 out of 17 pages
Add to cartRefrigeration technicians who violate the Clean Air Act can: - - ️️Lose their EPA certification, be fined, be required to appear in Federal court. 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - - ️️recovery and recycling. 
 
Refrige...
On low pressure chillers, moisture typically enters the refrigerant system through - ️️air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ️️10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a ...
Preview 2 out of 15 pages
Add to cartOn low pressure chillers, moisture typically enters the refrigerant system through - ️️air leaks from areas with gaskets or fittings 
 
The maximum test pressure for leak testing a low pressure centrifugal is: - ️️10 psig 
 
Leak test and repair the chiller to reduce refrigerant loss from a ...
When a new system has been assembled, the first thing to do is? - ️️Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ️️Pressurized with nitrogen then leak checked. 
 
The EPA regulations require t...
Preview 2 out of 8 pages
Add to cartWhen a new system has been assembled, the first thing to do is? - ️️Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ️️Pressurized with nitrogen then leak checked. 
 
The EPA regulations require t...
As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - ️️a. July 1, 1992 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the...
Preview 4 out of 89 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 - ️️a. July 1, 1992 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller jackline98. Stuvia facilitates payment to the seller.
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
75632 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now