Package deal
EPA 608 PACKAGE DEAL
EPA 608 PACKAGE DEAL
[Show more]EPA 608 PACKAGE DEAL
[Show more]What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? 
November 14, 1994 
 
 
 
Section 608 of the Federal Clean Air Act requires technicians to what? 
Recover all refrigerants. 
 
 
 
The objective of the Clean Air Act is to protect what? 
The earth...
Preview 2 out of 8 pages
Add to cartWhat date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? 
November 14, 1994 
 
 
 
Section 608 of the Federal Clean Air Act requires technicians to what? 
Recover all refrigerants. 
 
 
 
The objective of the Clean Air Act is to protect what? 
The earth...
a vacum pump should be connected 
as far away from the pump as possible 
 
 
 
a high capacity vacuum pump and short, large diameter hoses will 
dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
 
 
ozone contains three 
oxygen atoms 
 
 
 
one chlorine atom can destro...
Preview 2 out of 8 pages
Add to carta vacum pump should be connected 
as far away from the pump as possible 
 
 
 
a high capacity vacuum pump and short, large diameter hoses will 
dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
 
 
ozone contains three 
oxygen atoms 
 
 
 
one chlorine atom can destro...
Are there drop-in replacements for R-12 systems? Why or why not? 
No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
 
 
What type of oil is used in R-134a and what oils will it mix with? 
Ester based oils and they do not mix with other oils 
 
 
 ...
Preview 2 out of 12 pages
Add to cartAre there drop-in replacements for R-12 systems? Why or why not? 
No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
 
 
What type of oil is used in R-134a and what oils will it mix with? 
Ester based oils and they do not mix with other oils 
 
 
 ...
What are the typical uses of the center port of gauge set? 
Used during evacuation, charging and recovery procedures. 
 
 
 
What color are the gauges on a manifold gauge set? 
Low pressure is blue, High pressure is red. 
 
 
 
What are the typical ranges of pressure measurements used on the gauges ...
Preview 3 out of 30 pages
Add to cartWhat are the typical uses of the center port of gauge set? 
Used during evacuation, charging and recovery procedures. 
 
 
 
What color are the gauges on a manifold gauge set? 
Low pressure is blue, High pressure is red. 
 
 
 
What are the typical ranges of pressure measurements used on the gauges ...
As of what date did it become unlawful to release Class 1 and Class II refrigerants to the atmosphere? 
July 1, 1992. 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
Protective shield for Earth from the sun's harmful ultraviolent (UV) rays in the stratosphere layer that exte...
Preview 1 out of 3 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II refrigerants to the atmosphere? 
July 1, 1992. 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
Protective shield for Earth from the sun's harmful ultraviolent (UV) rays in the stratosphere layer that exte...
Which Refrigerants contain the most chlorine? 
CFC's 
 
 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? 
July 1, 1992 
 
 
 
Which Refrigerants have the lowest zone depletion potential? 
HFC's 
 
 
 
The molecule found in CFC...
Preview 2 out of 11 pages
Add to cartWhich Refrigerants contain the most chlorine? 
CFC's 
 
 
 
As of what date did it become unlawful to intentionally release Class 1 and Class 2 refrigerants to the atmosphere? 
July 1, 1992 
 
 
 
Which Refrigerants have the lowest zone depletion potential? 
HFC's 
 
 
 
The molecule found in CFC...
As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 
a. July 1, 1992 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the at...
Preview 4 out of 85 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 
a. July 1, 1992 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the at...
On low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
 
 
 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
 
 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge ...
Preview 2 out of 15 pages
Add to cartOn low pressure chillers, moisture typically enters the refrigerant system through 
air leaks from areas with gaskets or fittings 
 
 
 
The maximum test pressure for leak testing a low pressure centrifugal is: 
10 psig 
 
 
 
Leak test and repair the chiller to reduce refrigerant loss from a pruge ...
Refrigeration technicians who violate the Clean Air Act can: - 
Lose their EPA certification, be fined, be required to appear in Federal court. 
 
 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - 
recovery and recycling. 
 
 
 
Refrigerant t...
Preview 3 out of 17 pages
Add to cartRefrigeration technicians who violate the Clean Air Act can: - 
Lose their EPA certification, be fined, be required to appear in Federal court. 
 
 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - 
recovery and recycling. 
 
 
 
Refrigerant t...
When moisture exists in an operating system, what is most likely to occur? 
Acid will form. 
 
 
 
What factor(s) affects the speed of evacuation? 
1) The size of the equipment being evacuated. 
 
2)The ambient temperature. 
 
3) The amount of moisture in the system 
 
 
 
A system is considered deh...
Preview 1 out of 3 pages
Add to cartWhen moisture exists in an operating system, what is most likely to occur? 
Acid will form. 
 
 
 
What factor(s) affects the speed of evacuation? 
1) The size of the equipment being evacuated. 
 
2)The ambient temperature. 
 
3) The amount of moisture in the system 
 
 
 
A system is considered deh...
the state of the refrigerant entering the metering device is? 
A subcooled high pressure liquid. 
 
 
 
what type of refrigerant is used in VERY high-pressure appliances? 
R-503 
 
 
 
what type of refrigerant is used in MEDIUM pressure appliances? 
R-500 
 
 
 
what type of refrigerant is used in H...
Preview 3 out of 16 pages
Add to cartthe state of the refrigerant entering the metering device is? 
A subcooled high pressure liquid. 
 
 
 
what type of refrigerant is used in VERY high-pressure appliances? 
R-503 
 
 
 
what type of refrigerant is used in MEDIUM pressure appliances? 
R-500 
 
 
 
what type of refrigerant is used in H...
Ozone stratosphere above the earth consists of molecules containing... 
3 oxygen atoms (O3) 
 
 
 
The oxygen we breathe contains how many atoms in each molecule? 
two atoms (O2) 
 
 
 
The ozone layer consists of ozone in the stratosphere at an altitude of between __________above the earth 
7 and 2...
Preview 3 out of 17 pages
Add to cartOzone stratosphere above the earth consists of molecules containing... 
3 oxygen atoms (O3) 
 
 
 
The oxygen we breathe contains how many atoms in each molecule? 
two atoms (O2) 
 
 
 
The ozone layer consists of ozone in the stratosphere at an altitude of between __________above the earth 
7 and 2...
Type I 
Small appliances- 5lbs or less 
 
 
 
Type II 
Residental Units/ Light Commercial 
 
 
 
Type III 
Industrial 
 
 
 
Universal 
All types 
 
 
 
November 14th, 1994 
Section 608 of the federal clean air act requires all persons who maintain, service, repair or dispose of appliances that cont...
Preview 1 out of 4 pages
Add to cartType I 
Small appliances- 5lbs or less 
 
 
 
Type II 
Residental Units/ Light Commercial 
 
 
 
Type III 
Industrial 
 
 
 
Universal 
All types 
 
 
 
November 14th, 1994 
Section 608 of the federal clean air act requires all persons who maintain, service, repair or dispose of appliances that cont...
Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after 
November 15, 1993 
 
 
 
Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: 
...
Preview 1 out of 4 pages
Add to cartRecovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after 
November 15, 1993 
 
 
 
Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: 
...
How many types of HVAC certifications are there? 
There are 4 types. 
 
 
 
What does a metering device do? 
The metering device causes a reduction in pressure, and therefore a reduction in saturation temperature. 
 
 
 
What is absorbed in the evaporator? 
Heat is absorbed in the evaporator. 
 
 
 ...
Preview 3 out of 16 pages
Add to cartHow many types of HVAC certifications are there? 
There are 4 types. 
 
 
 
What does a metering device do? 
The metering device causes a reduction in pressure, and therefore a reduction in saturation temperature. 
 
 
 
What is absorbed in the evaporator? 
Heat is absorbed in the evaporator. 
 
 
 ...
The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. 
Restricted to technicians who are EPA certified and refrigerant recovery 
 
 
 
A small Pliance is defined as a system that is 
Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less 
...
Preview 2 out of 5 pages
Add to cartThe sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. 
Restricted to technicians who are EPA certified and refrigerant recovery 
 
 
 
A small Pliance is defined as a system that is 
Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less 
...
When a new system has been assembled, the first thing to do is? 
Pressurize the system with an inert gas & leak check. 
 
 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? 
Pressurized with nitrogen then leak checked. 
 
 
 
The EPA regulations require that an...
Preview 2 out of 8 pages
Add to cartWhen a new system has been assembled, the first thing to do is? 
Pressurize the system with an inert gas & leak check. 
 
 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? 
Pressurized with nitrogen then leak checked. 
 
 
 
The EPA regulations require that an...
Reusable refrigerant containers under high-pressure must be hydrostatically tested how often? 
5 years 
 
 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? 
$44,539 
 
 
 
HCFCs contain 
Hydrogen, Chlorine, Fluorin...
Preview 2 out of 11 pages
Add to cartReusable refrigerant containers under high-pressure must be hydrostatically tested how often? 
5 years 
 
 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? 
$44,539 
 
 
 
HCFCs contain 
Hydrogen, Chlorine, Fluorin...
Technicians who perform sealed system service on small appliances must have; 
Type I or universal certification 
 
 
 
A small appliance is defined by EPA as; 
Appliances manufactured, charged, and hermetically sealed in a factory with 5 lbs or less of refrigerant 
 
 
 
Type I Certification is requ...
Preview 1 out of 3 pages
Add to cartTechnicians who perform sealed system service on small appliances must have; 
Type I or universal certification 
 
 
 
A small appliance is defined by EPA as; 
Appliances manufactured, charged, and hermetically sealed in a factory with 5 lbs or less of refrigerant 
 
 
 
Type I Certification is requ...
What does ozone in the stratosphere above the earth consist of? 
Molecules containing 3 oxygen atoms 
 
 
 
Which of the following refrigerants has the lowest global warming potential? 
R-600a 
 
 
 
Which of the following gases is used as the baseline measurement for global warming potential? 
Carb...
Preview 2 out of 11 pages
Add to cartWhat does ozone in the stratosphere above the earth consist of? 
Molecules containing 3 oxygen atoms 
 
 
 
Which of the following refrigerants has the lowest global warming potential? 
R-600a 
 
 
 
Which of the following gases is used as the baseline measurement for global warming potential? 
Carb...
Industrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. 
35 
 
 
 
Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; 
30 days 
 
 
 
Refrigerants CFC R-12, HCFC R-22...
Preview 1 out of 3 pages
Add to cartIndustrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. 
35 
 
 
 
Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; 
30 days 
 
 
 
Refrigerants CFC R-12, HCFC R-22...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller FREEMANSHARP. Stuvia facilitates payment to the seller.
No, you only buy these notes for $39.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
79223 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now