Package deal
NATE Exam Bundle Graded A+
NATE Exam Bundle Graded A+
[Show more]NATE Exam Bundle Graded A+
[Show more]d (very important) - The ability to utilize all types of communication skills is ____ to the HVACR 
technician. 
a. not as important as "hands-on" technical skills 
b. somewhat important 
c. unimportant 
d. very important 
d (all of the above: clear, complete, concise) - It is important to be ____...
Preview 4 out of 33 pages
Add to cartd (very important) - The ability to utilize all types of communication skills is ____ to the HVACR 
technician. 
a. not as important as "hands-on" technical skills 
b. somewhat important 
c. unimportant 
d. very important 
d (all of the above: clear, complete, concise) - It is important to be ____...
Low airflow over a residential split system air conditioning evaporator can cause 
A: Liquid flood-back to the compressor 
B: A decrease in compression ratio 
C: An increase in suction line superheat 
D: Oil logging in the evaporator - A: Liquid flood-back to the compressor 
Which of the following i...
Preview 3 out of 20 pages
Add to cartLow airflow over a residential split system air conditioning evaporator can cause 
A: Liquid flood-back to the compressor 
B: A decrease in compression ratio 
C: An increase in suction line superheat 
D: Oil logging in the evaporator - A: Liquid flood-back to the compressor 
Which of the following i...
Which of the following factors affects a customer's level of comfort? 
a. Air movement 
b. Humidity 
c. Temperature 
d. All of the above - d (All of the above: air movement, humidity, temperature) 
A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible 
cap...
Preview 3 out of 27 pages
Add to cartWhich of the following factors affects a customer's level of comfort? 
a. Air movement 
b. Humidity 
c. Temperature 
d. All of the above - d (All of the above: air movement, humidity, temperature) 
A cooling load calculation estimates the sensible heat gain of a structure. The maximum sensible 
cap...
Charging a heat pump with refrigerant is best accomplished in the _______ mode. 
A: Heating mode 
B: Cooling mode 
C: Defrost mode 
D: Emergency heating mode - B: Cooling mode 
Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the 
heat pump more efficient...
Preview 3 out of 19 pages
Add to cartCharging a heat pump with refrigerant is best accomplished in the _______ mode. 
A: Heating mode 
B: Cooling mode 
C: Defrost mode 
D: Emergency heating mode - B: Cooling mode 
Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the 
heat pump more efficient...
A system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line 
set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added 
for each added foot of refrigerant line set length. What is the total refrigerant ch...
Preview 3 out of 27 pages
Add to cartA system is supplied from the factory with charge of 5 pounds 10 ounces for a 15 foot line set. The line 
set is 25 feet long. The manufacturer's instruction sheet specifies 0.6 ounces of refrigeration to be added 
for each added foot of refrigerant line set length. What is the total refrigerant ch...
What electro-mechanical control would you use on a cap tube or automatic expansion valve system to 
maintain the space temperature? - C: A thermostatic control 
Open motors are designed to operate at a given temperature rise as indicated on the motor nameplate. 
What does this mean? - A: indicates t...
Preview 2 out of 5 pages
Add to cartWhat electro-mechanical control would you use on a cap tube or automatic expansion valve system to 
maintain the space temperature? - C: A thermostatic control 
Open motors are designed to operate at a given temperature rise as indicated on the motor nameplate. 
What does this mean? - A: indicates t...
Since 1992, the United States Department of Energy has required that all furnaces sold and installed 
from that date on must have an AFUE of no less than: 
A: 70% 
B: 75% 
C: 78% 
D: 80% - C: 78% 
Many pre-1992 furnaces have efficiencies around _______. 
A: 10% 
B: 40% 
C: 60% 
D: 80% - C: 60% 
Toda...
Preview 3 out of 18 pages
Add to cartSince 1992, the United States Department of Energy has required that all furnaces sold and installed 
from that date on must have an AFUE of no less than: 
A: 70% 
B: 75% 
C: 78% 
D: 80% - C: 78% 
Many pre-1992 furnaces have efficiencies around _______. 
A: 10% 
B: 40% 
C: 60% 
D: 80% - C: 60% 
Toda...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller PatrickKaylian. Stuvia facilitates payment to the seller.
No, you only buy these notes for $18.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
79223 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now