Package deal
Bundle for Fire Inspector 2 Exams Compilation | Verified | Guaranteed Success
Bundle for Fire Inspector 2 Exams Compilation | Verified | Guaranteed Success
[Show more]Bundle for Fire Inspector 2 Exams Compilation | Verified | Guaranteed Success
[Show more]What two physical properties of flammable liquids are used to classify them? - 
A. Flash Point 
B. Boiling point 
The amount of heat given off by a particular substance during the combustion process is called? - 
Heat of Combustion 
The minimum temperature at which a liquid gives off sufficient vap...
Preview 2 out of 9 pages
Add to cartWhat two physical properties of flammable liquids are used to classify them? - 
A. Flash Point 
B. Boiling point 
The amount of heat given off by a particular substance during the combustion process is called? - 
Heat of Combustion 
The minimum temperature at which a liquid gives off sufficient vap...
Fire protection engineers have established _____ PSI as a minimum required residual pressure 
when computing the available water for flow test results. - 20psi 
The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ 
GPM. - 500 - 1500 gpm 
A fire pump serving a st...
Preview 2 out of 14 pages
Add to cartFire protection engineers have established _____ PSI as a minimum required residual pressure 
when computing the available water for flow test results. - 20psi 
The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ 
GPM. - 500 - 1500 gpm 
A fire pump serving a st...
A code is: - A legal requirement of a building feature or operating feature at a certain 
location 
A standard is: - A set of specifications or requirements that is considered industry best 
practice and meets a minimum level of performance guidelines 
The most important tool the fire inspector poss...
Preview 3 out of 20 pages
Add to cartA code is: - A legal requirement of a building feature or operating feature at a certain 
location 
A standard is: - A set of specifications or requirements that is considered industry best 
practice and meets a minimum level of performance guidelines 
The most important tool the fire inspector poss...
How big are DOT labels? - 4 inch square, on point 
Where is the primary DOT label? - On the left 
How many hazards can be on a DOT label? - several 
NFPA 704 - Hazardous Materials Marking System 
Placard: Blue means..... - Health Hazard 
Placard: Red means.... - Flammability Hazard 
Placard: Yellow ...
Preview 3 out of 27 pages
Add to cartHow big are DOT labels? - 4 inch square, on point 
Where is the primary DOT label? - On the left 
How many hazards can be on a DOT label? - several 
NFPA 704 - Hazardous Materials Marking System 
Placard: Blue means..... - Health Hazard 
Placard: Red means.... - Flammability Hazard 
Placard: Yellow ...
Fire protection engineers have established _____ PSI as a minimum required residual pressure 
when computing the available water for flow test results. - 20psi 
The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ 
GPM. - 500 - 1500 gpm 
A fire pump serving a st...
Preview 4 out of 34 pages
Add to cartFire protection engineers have established _____ PSI as a minimum required residual pressure 
when computing the available water for flow test results. - 20psi 
The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ 
GPM. - 500 - 1500 gpm 
A fire pump serving a st...
Where would you look to determine if the damper requirements have been included and correct 
on a set of drawings? - On the mechanical plan 
Which plans sheet gives specific details for exit signs? - Electrical plans 
Which plan would you look at to find exit door fire ratings? - Door schedule 
All ...
Preview 3 out of 18 pages
Add to cartWhere would you look to determine if the damper requirements have been included and correct 
on a set of drawings? - On the mechanical plan 
Which plans sheet gives specific details for exit signs? - Electrical plans 
Which plan would you look at to find exit door fire ratings? - Door schedule 
All ...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Tulloch. Stuvia facilitates payment to the seller.
No, you only buy these notes for $40.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
75759 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now