Journeyman Oil Maine Fuel Board Rules. Exam Questions With Correct Answers What must you do if you notice code violations in a homeowners house? - answerNotify them and recommend ways to address them What must be done when performing an annual tune-up on a heating system? - answerA combustion ...

[Show more]

Preview 2 out of 15  pages

  • November 12, 2024
  • 15
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Journeyman Oil Maine Fuel Board Rules
  • Journeyman Oil Maine Fuel Board Rules
avatar-seller
Thebright
©THEBRIGHT EXAM SOLUTIONS

11/05/2024 12:06 PM


Journeyman Oil Maine Fuel Board Rules.
Exam Questions With Correct Answers


What must you do if you notice code violations in a homeowners house? - answer✔Notify them
and recommend ways to address them

What must be done when performing an annual tune-up on a heating system? - answer✔A
combustion efficiency test and a copy must be posted on site
Whenever a furnace, direct fired hot water heater, or boiler is installed the total installation
must be brought into compliance with what requirements BEFORE appliance can be fired? -
answer✔NFPA 31
When an emergency arises that does not allow adequate time to get a chimney lined/and or
repaired before installing the new heating appliance the licensee may defer the required
repairs for how long? - answer✔90 days

What must be performed before a new installation? - answer✔A heat loss system design and
load calculation. A copy must be retained to be presented upon request of board inspector
All oil fired BOILERS must be provided with a properly installed and operating what? -
answer✔Low Water cut off

Where shall a low water cutoff be installed? - answer✔At the level recommended by the
manufacture, but in no case below the crown sheet
If the low water cut off is not installed directly in the boiler where may it be installed? -
answer✔Main supply line (vertical riser) as close to boiler as possible, or in a water column of
continuous piping attached directly to the boiler
A listed lever or wheel thermally operated oil shut off valve must be installed where? -
answer✔At the burner and the oil supply tank
When outside tanks are used a thermally operated shut off valve must be installed where? -
answer✔The supply line enters the inside of the building and where the oil line enters the room
where the appliance is located

, ©THEBRIGHT EXAM SOLUTIONS

11/05/2024 12:06 PM

When inside tanks are used and the oil supply tank is installed in a separate room, a thermally
shutoff valve must be installed where? - answer✔Where the line enters the room where the
appliance is located
Whenever the oil supply is taken from the top of an oil tank a thermally operated wheel or
lever type shut-off valve must be installed where? - answer✔At the tank and at the burner

What may be installed in the supply line but not a return line? - answer✔A check valve
All copper oil supply and return lines must be encased in a continuous piece of no metallic
liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the conduit shall not
exceed how far from any connection except the connection at fuel tank? - answer✔2 inches
In order to avoid undetected oil leaks under floors, the conduit must be how much bigger than
the supply and return lines? - answer✔One pipe size larger

An oil supply line that penetrates a foundation wall must be what? - answer✔Sealed
What must coated copper tubing have installed at the tank when used underground? -
answer✔Oils Safety Valve or PRV
When an oil filter or other accessory equipment is connected to a copper piping smaller than
3/4 "and is not directly connected to the oil tank or burner the filter or other device must be
what? - answer✔Rigidly supported by wall or floor mounted brackets

What must supply and return lines be connected with? - answer✔Flare fittings
What fittings shall not be used unless for introduction of lines at top of the tank with a single or
double tap bushing? - answer✔Compression fittings
All connections of supply or return oil lines located outside must be made with what? -
answer✔Flare frost fittings
Manholes 16 inches in diameter or larger must be installed in the top of all tanks over what? -
answer✔5,000 gallons or more
All fuel oil supply tanks must be a minimum of how many feet from any gas or solid fuel burning
appliance? - answer✔5 feet

Outside oil tanks shall not be installed on what? - answer✔Wood or other combustible surfaces
In all tank instillation's the pipe flanges must be in direct contact with reinforced concrete pad
or solid concrete blocks, what is not permitted? - answer✔Use of shims

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Thebright. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.49
  • (0)
  Add to cart