Engine Start Procedure as directed by the Captain - ANSWER-Pilot Starting Engines
4. Center Console when NH rotation is indicated
- Condition Lever: Start & Feather
- Engine Start: Monitor
Verify Nh Accelerates to green arc within 70 seconds
Verify ITT does not exceed 920 C
Verify Oil Pressure reaches 44 psi by start SELECT switch reset
Verify Start SELECT switch resets
After Start SELECT Switch Resets
FO: Air Conditioning Panel
- Bleed 1 or 2: (as appropriate) ON
Repeat Start Procedures for other engine after
- Select Light extinguishes
- Main BATT load of .40 or less is indicated on ELECTRICAL system page
After Both Engines Started
FO: Air Conditioning Panel
- Bleed 1 or 2: (as appropriate) ON
- Recirc Fan: Recirc
- APU GEN: Press Out
- APU PWR: Press Out
FO's After Landing Flow - ANSWER-1. Aft Center Console
- Flaps: Up
- Radar: STBY
, 2. Air Conditioning Panel
- Bleed 1&2: On
- Bleed Selector: As Desired
FO's After Start Flow to AC Gen extinguish - ANSWER-After Captain initiates their After
Start Flow
1. Engine Start Panel
- Verify Engine START and SELECT lights are extinguished. (15 sec.)
2. Air Conditioning Panel
- Bleed Flow Control: Normal position is min
- Recirc Fan: Verify Recirc
3. First Officers Displays
- MFD Electrical: Confirm DC EXT POWER is not displayed, MAIN, AUX, STBY BATT
is -20C or higher, BATT loads decreasing.
4. Hydraulic control Panel
- HYD #3 ISOL VLV: Press in (open)
5. Control Wheel
- Elevator Travel: Check ELEVATOR PRESS light illuminated, check for full travel
- Ailerons and Roll Spoilers: Check for free movement and appropriate indications on #1
MFD
6. Hydraulic Control Panel
- HYD #3 ISOL VLV: Press Out (Dark)
Continue after both AC GEN lights extinguish
7. Flaps
- Set for Takeoff
8. Hydraulic Control Panel
- STBY HYD PRESS: Press in (on) and pressure rises
- PTU CONTROL: Press in (on)
- Hydraulic Pressure: Check PK BRK, #1 and #2: 2900-3100 PSI, STBY 2800-3000 PSI
9. Center Console
- Tank 1 and 2 AUX PUMP switches: Press in (on)
- MTOP Switch (if used): Press in and check MTOP on PFD
- AUTOFEATHER Switch: Press in and verify A/F SELECT on MFD
- ESID Control Panel: Select #2 MFD to NAV
10. Deice Pressure 1 & 2 indicator
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller LUCKYSTAR2022. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.99. You're not tied to anything after your purchase.