100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Load Calculations - Branch And Feeder Circuits (Chapter 1): Questions/Solutions $9.99   Add to cart

Exam (elaborations)

Load Calculations - Branch And Feeder Circuits (Chapter 1): Questions/Solutions

 0 view  0 purchase
  • Course
  • LOAD CALCULATIONS
  • Institution
  • LOAD CALCULATIONS

Load Calculations - Branch And Feeder Circuits (Chapter 1): Questions/Solutions

Preview 2 out of 5  pages

  • November 7, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • LOAD CALCULATIONS
  • LOAD CALCULATIONS
avatar-seller
LeCrae
Load Calculations - Branch And Feeder Circuits
(Chapter 1): Questions/Solutions

What is the maximum continuous load that may be connected to a 20A, 120V
fuse? Right Ans - 20A x 80% or .80 = 16A (continuous loads are calculated
at 125% of the maximum current rating of the load. the reciprocal of 125% is
equivalent to 80%)

The voltage drop for a 208V, 1 ott circuit with a load of 28A, using No. 8
stranded copper conductors at the circuit length of 160' is....... Right Ans -
VD (Voltage Drop) = (2xLxRxI) / 1000, L- load center or total length in feet, R-
conductor resistance (NEC chapter 9, table 8), I- current.
(2x160ftx.776x80A)/1000 = 6.97V

The ampacity of a 120V, 1 ott load rated at 800VA is..... Right Ans - 800VA /
120V = 6.67A

Appliance Right Ans - utilization equipment, generally other than
industrial, normally built in standardized sizes or types, that is installed or
connected as a unit to perform one or more functions such as clothes washing,
air conditioning, food mixing, deep frying, or other purposes

Appliance branch circuits Right Ans - Branch circuits supplying energy to
one or more outlets to which appliances are to be connected. such circuits are
to have no permanently connected lighting fixtures that are not part of an
appliance

Demand factors Right Ans - ratio of the maximum demands of a system, or
part of a system, to the total connected load of a system or the part of the
system under consideration

General-purpose branch circuit Right Ans - Branch circuits that supply two
or more receptacles or outlets for lighting and appliances

What is the calculated load, in amps, for a 120V circuit supplying 8 recessed
fluorescent fixtures operating continuously? (Each fluorescent ballast is rated
at 0.5A.) Right Ans - 8 fixtures x 0.5A = 4A, 125% of 4A, 4Ax 1.25 = 5A

, What is the maximum number of continuous duty duplex receptacles that can
be connected to 20A, 120V circuit in a commercial building? Right Ans -
total circuit capacity = 20A x 120V = 2400VA, rating per receptacle = 180VA x
125% = 225VA, total loads that may be connected = (circuit capacity)/(rating
per receptacle) = 2400VA/225VA = 10.7 (round down) = 10 receptacles

What is the total load, in VA, for 4 small appliance branch circuits in a single-
family dwelling? Right Ans - 4 small appliances = 4 circuits, 4 circuits x
1500VA = 6000VA

What is the demand load for one household dryer with a nameplate rating
4.75kW? Right Ans - NEC section 220.54 household dryer load calculated at
either 5000VA or nameplate rating, whichever is larger, first convert the
nameplate dryer to VA and determine, which is larger
4.75kW x 1000 = 4750VA, 4750 < 5000VA

What is the demand load, in amps, for a small two-burner electric range with a
nameplate rating of 7kW, 1 ott, 240V Right Ans - Calculate 80% of the
nameplate rating, 7kW x 0.8 = 5.6kW, 5.6kW x 1000 = 5600VA, 5600VA/240V
= 23.3A

What is the ampacity of a water heater with a nameplate rating of 8400VA at
240V Right Ans - 8400VA/240V = 35A, 35A x 1.25 = 43.75A

What is the minimum conductor ampacity for four 1200W, 240V, 1 ott electric
baseboard heaters? Right Ans - 1200W x 4 heaters = 4800W = 4800VA,
4800VA/240V = 20A, 20A x 1.25 = 25A

What size copper branch circuit conductors are required to supply an air
conditioning unit with a nameplate rating of 18A, 240V, 3 ott? Right Ans -
find 125% of ampacity, 18A x 1.25 = 22.5A, looking at NEC table 310.16, 22.5A
= No. 10

Multi-outlet assembly Right Ans - type of surface, flush, or freestanding
raceway designed to hold conductors and receptacles, assembled in the field
or at the factory.

The load for 8' of multi-outlet assembly used simultaneously is Right Ans -
1 outlet considers 180VA, 8 x 180VA = 1440VA

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller LeCrae. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

82215 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99
  • (0)
  Add to cart