100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Fire Pump Ohio Test Study Guide Exam $8.49   Add to cart

Exam (elaborations)

Fire Pump Ohio Test Study Guide Exam

 4 views  0 purchase
  • Course
  • Fire Pump Ohio
  • Institution
  • Fire Pump Ohio

Fire Pump Ohio Test Study Guide Exam

Preview 1 out of 4  pages

  • November 5, 2024
  • 4
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Fire Pump Ohio
  • Fire Pump Ohio
avatar-seller
Nursephil2023
Fire Pump Ohio Test Study Guide
Exam
Per NFPA 20 requirements, which of the following is required to illuminate a
pump room or pump house. - -Artificial Light

- Before shipment from the factory, each pump shall be hydrostatically
tested by the manufacturer. The test pressure shall not be less than one-half
times the sum of the pump's shutoff heads plus its maximum allowable
suction head, but shall not be less than, - -200 PSI

- The weekly test for an electric pump requires the pump to run for a
minimum of - -10 Minutes

- The distance between the bottom of strainer and the bottom of the wet pit
on a vertical shaft turbine pump should be: - -One half of the pump diameter
but not less than 12 inches

- Engine generator sets supplying emergency or standby power to fire pump
assemblies shall be periodically tested in accordance with which of the
following NFPA standards: - -NFPA 110

- A pump for fire protection shall be selected to operate at less than or equal
to _% of the rated capacity. - -150

- A fire pump controller shall be permitted to be used as a junction box to
supply other equipment. - -False

- Authority Having Jurisdiction (AHJ) is the organization, office, or individual
responsible for approving equipment, materials, installations or procedures. -
-True

- Which of the following conditions requires the installation of a listed
indicating butterfly or gate valve and a drain valve or ball drip located in the
pipeline to the hose valve header: - -Both A and B

- The maximum allowable shutoff head for a pump with a rated capacity of
900 gpm and a rated head of 250 feet is: - -350 Feet

- Maximum number of drivers permitted to equip a fire pump is - -One

- Which of the following valves allows the diversion of liquid to limit excess
pressure in a system: - -A relief valve

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nursephil2023. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $8.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$8.49
  • (0)
  Add to cart