Winding Questions & Answers Requirement of producing emf Rate of change of magnetic flux/field wrt time, according to Faraday's laws of electromagnetic induction. Flux can also be a function of space angle, so that phi = f(t,theta). Flux only as a function of time Produces transformer emf...

[Show more]

Preview 2 out of 5  pages

  • October 20, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Wrt
  • Wrt
avatar-seller
Pogba119
Winding Questions & Answers
Requirement of producing emf - answer Rate of change of magnetic flux/field wrt
time, according to Faraday's laws of electromagnetic induction. Flux can also be a
function of space angle, so that phi = f(t,theta).

Flux only as a function of time - answer Produces transformer emf, e.g. transformer

Flux only as a function of space angle - answer Produces rotational emf, e.g. dc
machine, ac motors

Flux as an explicit function of time and phase angle - answer Present in an induction
motor

Coil sides - answer Refer to the S and F sides only. Thus no matter how many turns
the coil has, the total number of coil sides is always 2.

Total number of arm conductors - answer No. of coils (placed in slots over the
periphery of the armature surface) x No. of turns per coil x coil sides(2)

Why are arm conductors connected in series? - answer To increase voltage rating of
the machine, since greater length translates to greater ROTATIONAL emf. However,
voltage can't be increased indefinitely. The mica is slightly undercut. In case of lap
winding, if the voltage across the mica segment, i.e. across a coil exceeds 20-22 V,
flashover occurs, the coil gets shorted, and the machine may be damaged.

Why are arm conductors connected in parallel? - answer To increase current rating
of the machine. Each conductor can take only 200 A.

Constraints on arm conductor current - answer Current density of Cu must be kept
within 4-5 A/mm2, but cond cs can't be increased too much due to skin effect. So
optimum is 200 A max.

Wave winding specs - answer High voltage, low current, since number of parallel
paths low, a = 2

Lap winding specs - answer Low voltage, high current, since number of parallel
paths proportionately high, a = p

Armature winding - answer The procedure of interconnecting armature conductors
over the armature surface. Properties are that it is closed in a DC machine, and is
generally double layered to increase both v and i ratings, without unbalancing the flux
distribution.

, Why can't layers of arm conductors be increased indefinitely? - answer Problem of
flux penetration - due to the presence of air, the voltage induced in the lower layers is
always less than that in the upper layer. Since a coil has two sides, placing one in a top
layer and the other in a bottom layer assures an equal distribution, but more will upset
equilibrium. If such coils with unequal voltages are connected in series, circulating
currents will flow.

Pole pitch - answer Peripheral distance or separation between identical points on
two consecutive poles over the armature surface. Maybe in terms of length, or coil
sides. Generally length. Given by pi*D/p length, or (total no. of conductors/p) coil sides.
For wave, it is (total conductors +-1)/p.

Coil span - answer Peripheral distance or separation between the two sides of a
single coil in terms of no. of coil sides. If > = < pole pitch, termed over, full and
under/short/corded pitched. Generally full is used in DC to get max voltage. If other,
becomes e(1+cosa). Voltage decreases as a is changed from 0. At 90, the voltage
induced in the other side of coil = 0, hence this is neutral plane.

Back Pitch Yb - answer Peripheral distance or separation between the two sides of
the *same* coil, i.e. Si(odd) to Fi(even), measured at the back of the armature. Always
odd, since difference between odd and even.

Front Pitch Yf - answer Peripheral distance or separation along coil sides between
the two terminals connected to the same commutator segment, i.e. Fi(even) to
Si+1(odd), measured at the front of the armature. Always odd.

Commutator Pitch Yc - answer Peripheral distance between two commutator
segments connected to the two terminals of the same coil. In lap, it is 1 comm segment.
In wave, it is twice pole pitch, i.e. (c+-1)*2/p. Positive indicates progressive winding,
while negative is for retrogressive winding.

Resultant pitch Yr - answer Peripheral distance or separation between two
consecutive starting sides of coils(in terms of comm segments). Given by (Yb-Yf),
always even. In lap, +-2. In wave, 4(C+-1)/p.

Progressive Lap - answer Direction of tracing winding is same as direction of
progression of winding. Preferred in small applications since safer. Yb>Yf.

Retrogressive Lap - answer Direction of tracing the winding is opposite the direction
of progression of winding. Preferred in industrial applications since the -1 commutator
pitch equates to a saving of copper. However, because conductors cross more, the
rotation of armature may cause lateral displacement of crossed conductors, leading to
wearing of insulation and ultimately, a shorting. Yf<Yb

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Pogba119. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67163 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.99
  • (0)
  Add to cart